  • 21. Development of a dual modality imaging system: a combined gamma camera and optical imager.
    Jung JH; Choi Y; Hong KJ; Min BJ; Choi JY; Choe YS; Lee KH; Kim BT
    Phys Med Biol; 2009 Jul; 54(14):4547-59. PubMed ID: 19556682
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A comparison of clinical results in brain scanning using germanium semiconductor detectors and sodium iodide detectors.
    Behan M; Hudson FR; Ostrowski ST; Johnston RE; Tan KP; Glass HI; Lavender JP
    Br J Radiol; 1976 Jul; 49(583):618-23. PubMed ID: 974460
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Digital processing of images from a zone plate camera.
    Wilson BC; Parker RP; Dance DR
    Phys Med Biol; 1975 Sep; 20(3):757-70. PubMed ID: 1187777
    [TBL] [Abstract][Full Text] [Related]  

  • 24. BrachyView: proof-of-principle of a novel in-body gamma camera for low dose-rate prostate brachytherapy.
    Petasecca M; Loo KJ; Safavi-Naeini M; Han Z; Metcalfe PE; Meikle S; Pospisil S; Jakubek J; Bucci JA; Zaider M; Lerch ML; Qi Y; Rosenfeld AB
    Med Phys; 2013 Apr; 40(4):041709. PubMed ID: 23556879
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Collimation for imaging the myocardium. II.
    Graham LS; Poe ND; Robinson GD
    J Nucl Med; 1976 Aug; 17(8):719-23. PubMed ID: 932817
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Component resolution indices for scintillation camera systems.
    Brookeman V
    J Nucl Med; 1975 Mar; 16(3):228-30. PubMed ID: 1113172
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [A scanner using a coaxial Ge(Li) detector and scintitomography (author's transl)].
    Saegusa K; Arimizu N; Uchiyama G; Okano S
    Nihon Igaku Hoshasen Gakkai Zasshi; 1978 Mar; 38(3):230-7. PubMed ID: 662583
    [No Abstract]   [Full Text] [Related]  

  • 28. A large-area germanium detector for rectilinear scanning.
    Kraner HW; Llacer J; Atkins HL
    Radiology; 1973 Feb; 106(2):425-31. PubMed ID: 4684487
    [No Abstract]   [Full Text] [Related]  

  • 29. A prototype rotating slat collimator for single photon emission computed tomography.
    Lodge MA; Webb S; Flower MA; Binnie DM
    IEEE Trans Med Imaging; 1996; 15(4):500-11. PubMed ID: 18215931
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Thallium-201: scintillation camera imaging considerations.
    Groch MW; Lewis GK
    J Nucl Med; 1976 Feb; 17(02):142-5. PubMed ID: 1245877
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A prototype high-purity germanium detector system with fast photon-counting circuitry for medical imaging.
    Hasegawa BH; Stebler B; Rutt BK; Martinez A; Gingold EL; Barker CS; Faulkner KG; Cann CE; Boyd DP
    Med Phys; 1991; 18(5):900-9. PubMed ID: 1961152
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Collimation for imaging the myocardium.
    Graham LS; Poe ND; MacDonald NS
    J Nucl Med; 1976 May; 17(5):401-3. PubMed ID: 1262946
    [TBL] [Abstract][Full Text] [Related]  

  • 33. A performance comparison of novel cadmium-zinc-telluride camera and conventional SPECT/CT using anthropomorphic torso phantom and water bags to simulate soft tissue and breast attenuation.
    Liu CJ; Cheng JS; Chen YC; Huang YH; Yen RF
    Ann Nucl Med; 2015 May; 29(4):342-50. PubMed ID: 25628019
    [TBL] [Abstract][Full Text] [Related]  

  • 34. The design of the detector and collimators for a hybrid scanner.
    Vauramo E; Virjo A
    Br J Radiol; 1977 Nov; 50(599):808-13. PubMed ID: 588902
    [TBL] [Abstract][Full Text] [Related]  

  • 35. New knowledge about the bremsstrahlung image of strontium-89 with the scintillation camera.
    Narita H; Hirase K; Uchiyama M; Fukushi M
    Ann Nucl Med; 2012 Aug; 26(7):603-7. PubMed ID: 22767009
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Single-acquisition method for simultaneous determination of extrinsic gamma-camera sensitivity and spatial resolution.
    Santos JA; Sarmento S; Alves P; Torres MC; Bastos AL; Ponte F
    Appl Radiat Isot; 2008 Jan; 66(1):44-9. PubMed ID: 17855102
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Improving the spatial resolution of the multiple multiwire proportional chamber gamma camera.
    Bateman JE; Connolly JF
    Phys Med Biol; 1979 May; 24(3):639-42. PubMed ID: 461524
    [No Abstract]   [Full Text] [Related]  

  • 38. System characteristics of SPECT with a slat collimated strip detector.
    Vandenberghe S; Van Holen R; Staelens S; Lemahieu I
    Phys Med Biol; 2006 Jan; 51(2):391-405. PubMed ID: 16394346
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Intermetallic cobalt-gallium targets for production of germanium radioisotopes.
    Kutyreff CJ; Barnhart TE; Lo YH; Happel S; Nickles RJ; Ellison PA; Aluicio-Sarduy E; Engle JW
    Appl Radiat Isot; 2022 Sep; 187():110307. PubMed ID: 35696750
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Clinical tests on a prototype semiconductor gamma-camera.
    McCready VR; Parker RP; Gunnersen EM; Ellis R; Moss E; Gore WG; Bell J
    Br J Radiol; 1971 Jan; 44(517):58-62. PubMed ID: 5539401
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]