121 related articles for article (PubMed ID: 36967113)
1. Gamma auditory steady-state response as a promising electrophysiological biomarker for depression: an in vivo study with chronic unpredictable mild stress (CUS)-induced rats.
He Y; Guo W; Ren Z; Liang J; Liu S; Ming D
Cereb Cortex; 2023 Jun; 33(12):7741-7753. PubMed ID: 36967113
[TBL] [Abstract][Full Text] [Related]
2. Cortical volume and 40-Hz auditory-steady-state responses in patients with schizophrenia and healthy controls.
Kim S; Jang SK; Kim DW; Shim M; Kim YW; Im CH; Lee SH
Neuroimage Clin; 2019; 22():101732. PubMed ID: 30851675
[TBL] [Abstract][Full Text] [Related]
3. Emotional arousal modifies auditory steady state response in the auditory cortex and prefrontal cortex of rats.
Wang Y; Li Z; Tian Z; Wang X; Li Y; Qin L
Stress; 2019 Jul; 22(4):492-500. PubMed ID: 30896270
[TBL] [Abstract][Full Text] [Related]
4. Phase Delay of the 40 Hz Auditory Steady-State Response Localizes to Left Auditory Cortex in Schizophrenia.
Roach BJ; Hirano Y; Ford JM; Spencer KM; Mathalon DH
Clin EEG Neurosci; 2023 Jul; 54(4):370-378. PubMed ID: 36213937
[No Abstract] [Full Text] [Related]
5. Translating Adult Electrophysiology Findings to Younger Patient Populations: Difficulty Measuring 40-Hz Auditory Steady-State Responses in Typically Developing Children and Children with Autism Spectrum Disorder.
Edgar JC; Fisk CL; Liu S; Pandey J; Herrington JD; Schultz RT; Roberts TP
Dev Neurosci; 2016; 38(1):1-14. PubMed ID: 26730806
[TBL] [Abstract][Full Text] [Related]
6. Spontaneous Gamma Activity in Schizophrenia.
Hirano Y; Oribe N; Kanba S; Onitsuka T; Nestor PG; Spencer KM
JAMA Psychiatry; 2015 Aug; 72(8):813-21. PubMed ID: 25587799
[TBL] [Abstract][Full Text] [Related]
7. Effects of NMDA and GABA-A Receptor Antagonism on Auditory Steady-State Synchronization in Awake Behaving Rats.
Sullivan EM; Timi P; Hong LE; O'Donnell P
Int J Neuropsychopharmacol; 2015 Jan; 18(7):pyu118. PubMed ID: 25556198
[TBL] [Abstract][Full Text] [Related]
8. The age-related changes in 40 Hz Auditory Steady-State Response and sustained Event-Related Fields to the same amplitude-modulated tones in typically developing children: A magnetoencephalography study.
Arutiunian V; Arcara G; Buyanova I; Gomozova M; Dragoy O
Hum Brain Mapp; 2022 Dec; 43(17):5370-5383. PubMed ID: 35833318
[TBL] [Abstract][Full Text] [Related]
9. Neural network dynamics underlying gamma synchronization deficits in schizophrenia.
Koshiyama D; Miyakoshi M; Joshi YB; Molina JL; Tanaka-Koshiyama K; Joyce Sprock ; Braff DL; Swerdlow NR; Light GA
Prog Neuropsychopharmacol Biol Psychiatry; 2021 Apr; 107():110224. PubMed ID: 33340619
[TBL] [Abstract][Full Text] [Related]
10. Reduced high and low frequency gamma synchronization in patients with chronic schizophrenia.
Tsuchimoto R; Kanba S; Hirano S; Oribe N; Ueno T; Hirano Y; Nakamura I; Oda Y; Miura T; Onitsuka T
Schizophr Res; 2011 Dec; 133(1-3):99-105. PubMed ID: 21849245
[TBL] [Abstract][Full Text] [Related]
11. Differential Effects of Clozapine and Haloperidol on the 40 Hz Auditory Steady State Response-mediated Phase Resetting in the Prefrontal Cortex of the Female Sprague Dawley Rat.
Ummear Raza M; Gautam D; Rorie D; Sivarao DV
Schizophr Bull; 2023 May; 49(3):581-591. PubMed ID: 36691888
[TBL] [Abstract][Full Text] [Related]
12. Phencyclidine Disrupts the Auditory Steady State Response in Rats.
Leishman E; O'Donnell BF; Millward JB; Vohs JL; Rass O; Krishnan GP; Bolbecker AR; Morzorati SL
PLoS One; 2015; 10(8):e0134979. PubMed ID: 26258486
[TBL] [Abstract][Full Text] [Related]
13. Auditory Steady State Response; nature and utility as a translational science tool.
Kozono N; Honda S; Tada M; Kirihara K; Zhao Z; Jinde S; Uka T; Yamada H; Matsumoto M; Kasai K; Mihara T
Sci Rep; 2019 Jun; 9(1):8454. PubMed ID: 31186500
[TBL] [Abstract][Full Text] [Related]
14. Cortical connectomic mediations on gamma band synchronization in schizophrenia.
Du X; Hare S; Summerfelt A; Adhikari BM; Garcia L; Marshall W; Zan P; Kvarta M; Goldwaser E; Bruce H; Gao S; Sampath H; Kochunov P; Simon JZ; Hong LE
Transl Psychiatry; 2023 Jan; 13(1):13. PubMed ID: 36653335
[TBL] [Abstract][Full Text] [Related]
15. 40-Hz Auditory Steady-State Responses Characterize Circuit Dysfunctions and Predict Clinical Outcomes in Clinical High-Risk for Psychosis Participants: A Magnetoencephalography Study.
Grent-'t-Jong T; Gajwani R; Gross J; Gumley AI; Krishnadas R; Lawrie SM; Schwannauer M; Schultze-Lutter F; Uhlhaas PJ
Biol Psychiatry; 2021 Sep; 90(6):419-429. PubMed ID: 34116790
[TBL] [Abstract][Full Text] [Related]
16. Neuronal imbalance of excitation and inhibition in schizophrenia: a scoping review of gamma-band ASSR findings.
Onitsuka T; Tsuchimoto R; Oribe N; Spencer KM; Hirano Y
Psychiatry Clin Neurosci; 2022 Dec; 76(12):610-619. PubMed ID: 36069299
[TBL] [Abstract][Full Text] [Related]
17. Phase-locking index and power of 40-Hz auditory steady-state response are not related to major personality trait dimensions.
Korostenskaja M; Ruksenas O; Pipinis E; Griskova-Bulanova I
Exp Brain Res; 2016 Mar; 234(3):711-9. PubMed ID: 26586270
[TBL] [Abstract][Full Text] [Related]
18. Suppression of Low-Frequency Gamma Oscillations by Activation of 40-Hz Oscillation.
Sugiyama S; Taniguchi T; Kinukawa T; Takeuchi N; Ohi K; Shioiri T; Nishihara M; Inui K
Cereb Cortex; 2022 Jun; 32(13):2785-2796. PubMed ID: 34689202
[TBL] [Abstract][Full Text] [Related]
19. A distributed frontotemporal network underlies gamma-band synchronization impairments in schizophrenia patients.
Koshiyama D; Miyakoshi M; Joshi YB; Molina JL; Tanaka-Koshiyama K; Sprock J; Braff DL; Swerdlow NR; Light GA
Neuropsychopharmacology; 2020 Dec; 45(13):2198-2206. PubMed ID: 32829382
[TBL] [Abstract][Full Text] [Related]
20. 22q11.2 Deletion Syndrome Is Associated With Impaired Auditory Steady-State Gamma Response.
Larsen KM; Pellegrino G; Birknow MR; Kjær TN; Baaré WFC; Didriksen M; Olsen L; Werge T; Mørup M; Siebner HR
Schizophr Bull; 2018 Feb; 44(2):388-397. PubMed ID: 28521049
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]