153 related articles for article (PubMed ID: 36991560)
1. Trifecta and Carpentier Edwards aortic bioprostheses: Comparison of six years follow-up outcomes.
Pfister R; Frey V; Kirsch M; Tozzi P; Delay D; Gunga Z; Prêtre R; Niclauss L
Asian Cardiovasc Thorac Ann; 2023 May; 31(4):312-320. PubMed ID: 36991560
[TBL] [Abstract][Full Text] [Related]
2. Trifecta versus Perimount Magna Ease aortic valves: Failure mechanisms.
Suzuki R; Ito T; Suzuki M; Ohori S; Takayanagi R; Miura S
Asian Cardiovasc Thorac Ann; 2022 Sep; 30(7):797-806. PubMed ID: 35603636
[TBL] [Abstract][Full Text] [Related]
3. The new St Jude Trifecta versus Carpentier-Edwards Perimount Magna and Magna Ease aortic bioprosthesis: is there a hemodynamic superiority?
Wendt D; Thielmann M; Plicht B; Aßmann J; Price V; Neuhäuser M; Jakob H
J Thorac Cardiovasc Surg; 2014 May; 147(5):1553-60. PubMed ID: 23870159
[TBL] [Abstract][Full Text] [Related]
4. Six-year follow-up of aortic valve reoperation rates: Carpentier-Edwards Perimount versus St. Jude Medical Trifecta.
Stubeda H; Aliter H; Gainer RA; Theriault C; Doucette S; Hirsch GM
J Card Surg; 2020 Dec; 35(12):3347-3353. PubMed ID: 32985014
[TBL] [Abstract][Full Text] [Related]
5. Durability and Performance of 2298 Trifecta Aortic Valve Prostheses: A Propensity-Matched Analysis.
Yongue C; Lopez DC; Soltesz EG; Roselli EE; Bakaeen FG; Gillinov AM; Pettersson GB; Semple ME; Rajeswaran J; Tong MZ; Jaber W; Blackstone EH; Svensson LG; Johnston DR
Ann Thorac Surg; 2021 Apr; 111(4):1198-1205. PubMed ID: 33011168
[TBL] [Abstract][Full Text] [Related]
6. Comparison of early hemodynamic performance of 3 aortic valve bioprostheses.
Ugur M; Suri RM; Daly RC; Dearani JA; Park SJ; Joyce LD; Burkhart HM; Greason KL; Schaff HV
J Thorac Cardiovasc Surg; 2014 Nov; 148(5):1940-6. PubMed ID: 24530199
[TBL] [Abstract][Full Text] [Related]
7. 5-Year haemodynamic performance of three aortic bioprostheses. A randomized clinical trial.
Montero Cruces L; Carnero Alcázar M; Pérez Camargo D; Cobiella Carnicer J; Campelos Fernández P; Reguillo Lacruz FJ; Maroto Castellanos LC
Eur J Cardiothorac Surg; 2023 Aug; 64(2):. PubMed ID: 37471587
[TBL] [Abstract][Full Text] [Related]
8. Stentless aortic valve replacement: an update.
Kobayashi J
Vasc Health Risk Manag; 2011; 7():345-51. PubMed ID: 21731886
[TBL] [Abstract][Full Text] [Related]
9. Ten-year comparison of pericardial tissue valves versus mechanical prostheses for aortic valve replacement in patients younger than 60 years of age.
Weber A; Noureddine H; Englberger L; Dick F; Gahl B; Aymard T; Czerny M; Tevaearai H; Stalder M; Carrel TP
J Thorac Cardiovasc Surg; 2012 Nov; 144(5):1075-83. PubMed ID: 22341653
[TBL] [Abstract][Full Text] [Related]
10. Influence of completely supra-annular placement of bioprostheses on exercise hemodynamics in patients with a small aortic annulus.
Wagner IM; Eichinger WB; Bleiziffer S; Botzenhardt F; Gebauer I; Guenzinger R; Bauernschmitt R; Lange R
J Thorac Cardiovasc Surg; 2007 May; 133(5):1234-41. PubMed ID: 17467435
[TBL] [Abstract][Full Text] [Related]
11. Trifecta Versus Perimount Magna Ease Aortic Valve Prostheses.
Biancari F; Valtola A; Juvonen T; Husso A; Dahlbacka S; Laakso T; Jalava MP; Tauriainen T; Ahvenvaara T; Kinnunen EM; Niemelä M; Mäkikallio T; Eskola M; Virtanen MPO; Maaranen P; Rosato S; Anttila V; Vento A; Airaksinen J; Raivio P
Ann Thorac Surg; 2020 Sep; 110(3):879-888. PubMed ID: 32061588
[TBL] [Abstract][Full Text] [Related]
12. Aortic Valve Replacement With Carpentier-Edwards: Hemodynamic Outcomes for the 19-mm Valve.
You JH; Jeong DS; Sung K; Kim WS; Carriere KC; Lee YT; Park PW
Ann Thorac Surg; 2016 Jun; 101(6):2209-16. PubMed ID: 26872735
[TBL] [Abstract][Full Text] [Related]
13. Comprehensive hemodynamic performance and frequency of patient-prosthesis mismatch of the St. Jude Medical Trifecta bioprosthetic aortic valve.
Yadlapati A; Diep J; Barnes MJ; Grogan T; Bethencourt DM; Vorobiof G
J Heart Valve Dis; 2014 Jul; 23(4):516-23. PubMed ID: 25803979
[TBL] [Abstract][Full Text] [Related]
14. Comprehensive hemodynamic comparison and frequency of patient-prosthesis mismatch between the St. Jude Medical Trifecta and Epic Bioprosthetic aortic valves.
Yadlapati A; Diep J; Barnes M; Grogan T; Bethencourt DM; Vorobiof G
J Am Soc Echocardiogr; 2014 Jun; 27(6):581-9. PubMed ID: 24534651
[TBL] [Abstract][Full Text] [Related]
15. Sutureless Perceval aortic valve in comparison with the stented Carpentier-Edwards Perimount aortic valve.
König KC; Wahlers T; Scherner M; Wippermann J
J Heart Valve Dis; 2014 Mar; 23(2):253-8. PubMed ID: 25076560
[TBL] [Abstract][Full Text] [Related]
16. St. Jude Trifecta versus Carpentier-Edwards Perimount Magna valves for the treatment of aortic stenosis: comparison of early Doppler-echocardiography and hemodynamic performance.
Minardi G; Pergolini A; Zampi G; Pulignano G; Pero G; Sbaraglia F; Pino PG; Cioffi G; Musumeci F
Monaldi Arch Chest Dis; 2013 Sep; 80(3):126-32. PubMed ID: 24818319
[TBL] [Abstract][Full Text] [Related]
17. Aortic valve biologic protheses: A cohort comparison of premature valve failure.
Yount KW; Hawkins RB; Mehaffey JH; Teman NR; Yarboro LT; Kern JA; Ailawadi G
J Card Surg; 2022 May; 37(5):1224-1229. PubMed ID: 35245397
[TBL] [Abstract][Full Text] [Related]
18. Comparable long-term results for porcine and pericardial prostheses after isolated aortic valve replacement.
Andreas M; Wallner S; Ruetzler K; Wiedemann D; Ehrlich M; Heinze G; Binder T; Moritz A; Hiesmayr MJ; Kocher A; Laufer G
Eur J Cardiothorac Surg; 2015 Oct; 48(4):557-61. PubMed ID: 25527170
[TBL] [Abstract][Full Text] [Related]
19. The Hemodynamic Performance of the Perceval Sutureless Aortic Valve in a Propensity-Matched Comparison to the Carpentier-Edwards Perimount and Perimount Magna Ease Valves for Aortic Valve Replacement.
Kueri S; Berger T; Puiu PC; Alhamami Y; Diab N; Czerny M; Hochholzer W; Siepe M
Thorac Cardiovasc Surg; 2023 Oct; 71(7):542-549. PubMed ID: 35987191
[TBL] [Abstract][Full Text] [Related]
20. Mid-term comparative follow-up after aortic valve replacement with Carpentier-Edwards and Pericarbon pericardial prostheses.
Le Tourneau T; Savoye C; McFadden EP; Grandmougin D; Carton HF; Hennequin JL; Dubar A; Fayad G; Warembourg H
Circulation; 1999 Nov; 100(19 Suppl):II11-6. PubMed ID: 10567272
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]