153 related articles for article (PubMed ID: 36991560)
21. Early hemodynamic evaluation of Trifecta and Freestyle bioprostheses in patients with a small aortic root: preliminary results from a prospective randomized study.
Tasca G; Stefano A; Giannico F; Lobiati E; Riva B; Galanti A; Triggiani M; Gamba A
J Heart Valve Dis; 2014 Sep; 23(5):633-41. PubMed ID: 25799714
[TBL] [Abstract][Full Text] [Related]
22. Reintervention After Aortic Valve Replacement: Comparison of 3 Aortic Bioprostheses.
Lam KY; Koene B; Timmermans N; Soliman-Hamad M; van Straten A
Ann Thorac Surg; 2020 Aug; 110(2):615-621. PubMed ID: 31846642
[TBL] [Abstract][Full Text] [Related]
23. Outcomes of surgical aortic valve replacement using Carpentier-Edwards PERIMOUNT bioprosthesis series in elderly patients with severe aortic valve stenosis: a retrospective cohort study.
Nishioka N; Yamada A; Ujihira K; Iba Y; Maruyama R; Hatta E; Kurimoto Y; Nakanishi K
Gen Thorac Cardiovasc Surg; 2016 Dec; 64(12):728-734. PubMed ID: 27491542
[TBL] [Abstract][Full Text] [Related]
24. Rest and exercise hemodynamics following aortic valve replacement. A comparison between 19 and 21 mm Ionescu-Shiley pericardial and Carpentier-Edwards porcine valves.
Bove EL; Marvasti MA; Potts JL; Reger MJ; Zamora JL; Eich RH; Parker FB
J Thorac Cardiovasc Surg; 1985 Nov; 90(5):750-5. PubMed ID: 4058047
[TBL] [Abstract][Full Text] [Related]
25. Carpentier-Edwards Magna Ease bioprosthesis: a multicentre clinical experience and 12-year durability.
Piperata A; Fiocco A; Cavicchiolo A; Ponzoni M; Pesce R; Gemelli M; Evangelista G; Gastino E; Michelotti S; Mazzaro E; Garufi L; DePaulis R; Zanella L; Nadali M; Mangino D; Lorenzoni G; Gregori D; Jorgji V; Gerosa G; Bottio T
Eur J Cardiothorac Surg; 2022 Mar; 61(4):888-896. PubMed ID: 34962258
[TBL] [Abstract][Full Text] [Related]
26. Mid-term haemodynamic and clinical results after aortic valve replacement using the Freedom Solo stentless bioprosthesis versus the Carpentier Edwards Perimount stented bioprosthesis.
van der Straaten EP; Rademakers LM; van Straten AH; Houterman S; Tan ME; Soliman Hamad MA
Eur J Cardiothorac Surg; 2016 Apr; 49(4):1174-80. PubMed ID: 26224338
[TBL] [Abstract][Full Text] [Related]
27. Stentless Pericarbon Freedom Versus Stented Perimount Aortic Bioprosthesis: Propensity-Matched Long-Term Follow-Up.
Stefanelli G; Pirro F; Smorto V; Bellisario A; Chiurlia E; Weltert L
Innovations (Phila); 2020; 15(5):440-448. PubMed ID: 32628077
[TBL] [Abstract][Full Text] [Related]
28. Stentless vs Stented Aortic Valve Bioprostheses in the Small Aortic Root.
Wollersheim LW; Li WW; Kaya A; Bouma BJ; Driessen AH; van Boven WJ; van der Meulen J; de Mol BA
Semin Thorac Cardiovasc Surg; 2016 Summer; 28(2):390-397. PubMed ID: 28043449
[TBL] [Abstract][Full Text] [Related]
29. Randomized comparison of exercise haemodynamics of Freestyle, Magna Ease and Trifecta bioprostheses after aortic valve replacement for severe aortic stenosis.
Bach DS; Patel HJ; Kolias TJ; Deeb GM
Eur J Cardiothorac Surg; 2016 Aug; 50(2):361-7. PubMed ID: 26819292
[TBL] [Abstract][Full Text] [Related]
30. Absence of prosthesis-patient mismatch with the new generation of Edwards stented aortic bioprosthesis.
Wyss TR; Bigler M; Stalder M; Englberger L; Aymard T; Kadner A; Carrel TP
Interact Cardiovasc Thorac Surg; 2010 Jun; 10(6):884-7; discussion 887-8. PubMed ID: 20233807
[TBL] [Abstract][Full Text] [Related]
31. Late hemodynamic and clinical outcomes of aortic valve replacement with the Carpentier-Edwards Perimount pericardial bioprosthesis.
Dellgren G; David TE; Raanani E; Armstrong S; Ivanov J; Rakowski H
J Thorac Cardiovasc Surg; 2002 Jul; 124(1):146-54. PubMed ID: 12091820
[TBL] [Abstract][Full Text] [Related]
32. Mid-term follow-up after aortic valve replacement with the Carpentier Edwards Magna Ease prosthesis.
Rajab TK; Ali JM; Hernández-Sánchez J; Mackie J; Grimaudo V; Sinichino S; Mills C; Rana B; Dunning J; Abu-Omar Y
J Cardiothorac Surg; 2020 Aug; 15(1):209. PubMed ID: 32746882
[TBL] [Abstract][Full Text] [Related]
33. Late outcomes for aortic valve replacement with the Carpentier-Edwards pericardial bioprosthesis: up to 17-year follow-up in 1,000 patients.
McClure RS; Narayanasamy N; Wiegerinck E; Lipsitz S; Maloney A; Byrne JG; Aranki SF; Couper GS; Cohn LH
Ann Thorac Surg; 2010 May; 89(5):1410-6. PubMed ID: 20417753
[TBL] [Abstract][Full Text] [Related]
34. Impact of sinuses of Valsalva on prosthesis durability in patients undergoing ascending aorta and aortic valve replacement with Carpentier-Edwards bioprosthesis: a propensity score-based study.
Ius F; Koigeldiyev N; Roumieh M; Ismail I; Tudorache I; Shrestha M; Fleissner F; Haverich A; Cebotari S
Eur J Cardiothorac Surg; 2016 Jun; 49(6):1676-84. PubMed ID: 26656448
[TBL] [Abstract][Full Text] [Related]
35. Hemodynamic performance of Trifecta: single-center experience of 400 patients.
Modi A; Budra M; Miskolczi S; Velissaris T; Kaarne M; Barlow CW; Livesey SA; Ohri SK; Tsang GM
Asian Cardiovasc Thorac Ann; 2015 Feb; 23(2):140-5. PubMed ID: 24823382
[TBL] [Abstract][Full Text] [Related]
36. Early in-vivo hemodynamic comparison of supra-annular aortic bioprostheses: Trifecta versus Perimount Magna Ease.
Modi A; Pousios D; Sadeque S; Velissaris T; Barlow C; Livesey S; Tsang GM; Ohri SK
J Heart Valve Dis; 2014 May; 23(3):325-32. PubMed ID: 25296457
[TBL] [Abstract][Full Text] [Related]
37. Surgical sutureless and transcatheter aortic valves: hemodynamic performance and clinical outcomes in propensity score-matched high-risk populations with severe aortic stenosis.
Kamperidis V; van Rosendael PJ; de Weger A; Katsanos S; Regeer M; van der Kley F; Mertens B; Sianos G; Ajmone Marsan N; Bax JJ; Delgado V
JACC Cardiovasc Interv; 2015 Apr; 8(5):670-7. PubMed ID: 25946438
[TBL] [Abstract][Full Text] [Related]
38. Comparison of early haemodynamics of 19-mm aortic valve bioprostheses in patients with a small aortic annulus.
Domoto S; Niinami H; Uwabe K; Koike H; Tabata M; Morita K; Kambe M; Iguchi A
Interact Cardiovasc Thorac Surg; 2016 Jan; 22(1):19-25. PubMed ID: 26467641
[TBL] [Abstract][Full Text] [Related]
39. Trifecta has lower gradient and less prosthesis-patient mismatch than Mosaic Ultra in the aortic position: A prospective randomized study.
Braathen B; Husebye T; Lunde IG; Tønnessen T
J Thorac Cardiovasc Surg; 2019 Oct; 158(4):1032-1039. PubMed ID: 30635187
[TBL] [Abstract][Full Text] [Related]
40. Very long-term outcomes of the Carpentier-Edwards Perimount aortic valve in patients aged 50-65 years.
Bourguignon T; Lhommet P; El Khoury R; Candolfi P; Loardi C; Mirza A; Boulanger-Lothion J; Bouquiaux-Stablo-Duncan AL; Marchand M; Aupart M
Eur J Cardiothorac Surg; 2016 May; 49(5):1462-8. PubMed ID: 26530269
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]