BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

159 related articles for article (PubMed ID: 36995375)

  • 21. Comparison of contrast-enhanced fat-suppressed T1-3D-VIBE and T1-TSE MRI in evaluating anal fistula.
    Zhao J; Lu F; Wang Q; Lu H; Liu M; Zhang Z; Gong Z; Huang Y; Yang W; Zhan S; Yang S
    Abdom Radiol (NY); 2022 Nov; 47(11):3688-3697. PubMed ID: 36088602
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Comprehensive Dynamic Contrast-Enhanced 3D Magnetic Resonance Imaging of the Breast With Fat/Water Separation and High Spatiotemporal Resolution Using Radial Sampling, Compressed Sensing, and Parallel Imaging.
    Benkert T; Block KT; Heller S; Moccaldi M; Sodickson DK; Kim SG; Moy L
    Invest Radiol; 2017 Oct; 52(10):583-589. PubMed ID: 28398929
    [TBL] [Abstract][Full Text] [Related]  

  • 23. High spatial resolution, respiratory-gated, t1-weighted magnetic resonance imaging of the liver and the biliary tract during the hepatobiliary phase of gadoxetic Acid-enhanced magnetic resonance imaging.
    Lee ES; Lee JM; Yu MH; Shin CI; Woo HS; Joo I; Stemmer A; Han JK; Choi BI
    J Comput Assist Tomogr; 2014; 38(3):360-6. PubMed ID: 24681858
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Comparison of conventional DCE-MRI and a novel golden-angle radial multicoil compressed sensing method for the evaluation of breast lesion conspicuity.
    Heacock L; Gao Y; Heller SL; Melsaether AN; Babb JS; Block TK; Otazo R; Kim SG; Moy L
    J Magn Reson Imaging; 2017 Jun; 45(6):1746-1752. PubMed ID: 27859874
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Detection of the glenoid bare spot by non-arthrographic MR imaging, conventional MR arthrography, and 3D high-resolution T1-weighted VIBE MR arthrography: comparison with CT arthrography.
    Ozel MA; Ogul H; Koksal A; Kose M; Tuncer K; Eren S; Kantarci M
    Eur Radiol; 2023 May; 33(5):3276-3285. PubMed ID: 36792853
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Usefulness of the Delay Alternating with Nutation for Tailored Excitation Pulse with T1-Weighted Sampling Perfection with Application-Optimized Contrasts Using Different Flip Angle Evolution in the Detection of Cerebral Metastases: Comparison with MPRAGE Imaging.
    Kim D; Heo YJ; Jeong HW; Baek JW; Han JY; Lee JY; Jin SC; Baek HJ
    AJNR Am J Neuroradiol; 2019 Sep; 40(9):1469-1475. PubMed ID: 31371358
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Free-breathing dynamic liver examination using a radial 3D T1-weighted gradient echo sequence with moderate undersampling for patients with limited breath-holding capacity.
    Kaltenbach B; Roman A; Polkowski C; Gruber-Rouh T; Bauer RW; Hammerstingl R; Vogl TJ; Zangos S
    Eur J Radiol; 2017 Jan; 86():26-32. PubMed ID: 28027757
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Stereotactic radiotherapy of brain metastases: clinical impact of three-dimensional SPACE imaging for 3T-MRI-based treatment planning.
    Welzel T; El Shafie RA; V Nettelbladt B; Bernhardt D; Rieken S; Debus J
    Strahlenther Onkol; 2022 Oct; 198(10):926-933. PubMed ID: 35976408
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Three-dimensional fat-saturated T1-weighted Cartesian volumetric interpolated breath-hold examination (VIBE) for the diagnosis of aortitis in patients with suspected large vessel vasculitis: a comparative study with
    Einspieler I; Henninger M; Mergen V; Wendorff H; Haller B; Eiber M; Rummeny EJ; Schwaiger M; Moog P; Thürmel K
    Clin Radiol; 2019 Sep; 74(9):731.e11-731.e19. PubMed ID: 31130228
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Free-breathing radial 3D fat-suppressed T1-weighted gradient echo sequence: a viable alternative for contrast-enhanced liver imaging in patients unable to suspend respiration.
    Chandarana H; Block TK; Rosenkrantz AB; Lim RP; Kim D; Mossa DJ; Babb JS; Kiefer B; Lee VS
    Invest Radiol; 2011 Oct; 46(10):648-53. PubMed ID: 21577119
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Improved detection of erosions in the sacroiliac joints on MRI with volumetric interpolated breath-hold examination (VIBE): results from the SIMACT study.
    Diekhoff T; Greese J; Sieper J; Poddubnyy D; Hamm B; Hermann KA
    Ann Rheum Dis; 2018 Nov; 77(11):1585-1589. PubMed ID: 30097454
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Contrast-enhanced 3-dimensional SPACE versus MP-RAGE for the detection of brain metastases: considerations with a 32-channel head coil.
    Reichert M; Morelli JN; Runge VM; Tao A; von Ritschl R; von Ritschl A; Padua A; Dix JE; Marra MJ; Schoenberg SO; Attenberger UI
    Invest Radiol; 2013 Jan; 48(1):55-60. PubMed ID: 23192164
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Combined Deep Learning-based Super-Resolution and Partial Fourier Reconstruction for Gradient Echo Sequences in Abdominal MRI at 3 Tesla: Shortening Breath-Hold Time and Improving Image Sharpness and Lesion Conspicuity.
    Almansour H; Herrmann J; Gassenmaier S; Lingg A; Nickel MD; Kannengiesser S; Arberet S; Othman AE; Afat S
    Acad Radiol; 2023 May; 30(5):863-872. PubMed ID: 35810067
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Usefulness of Wave-CAIPI for Postcontrast 3D T1-SPACE in the Evaluation of Brain Metastases.
    Baek HJ; Heo YJ; Kim D; Yun SY; Baek JW; Jeong HW; Choo HJ; Lee JY; Oh SI
    AJNR Am J Neuroradiol; 2022 Jun; 43(6):857-863. PubMed ID: 35618423
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Nonlesional Sources of Contrast Enhancement on Postgadolinium "Black-Blood" 3D T1-SPACE Images in Patients with Multiple Sclerosis.
    Danieli L; Roccatagliata L; Distefano D; Prodi E; Riccitelli GC; Diociasi A; Carmisciano L; Cianfoni A; Bartalena T; Kaelin-Lang A; Gobbi C; Zecca C; Pravatà E
    AJNR Am J Neuroradiol; 2022 Jun; 43(6):872-880. PubMed ID: 35618421
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Combination of free-breathing radial 3D fat-suppressed T1-weighted gradient-echo sequence with diffusion weighted images: Potential for differentiating malignant from benign peripheral solid pulmonary masses.
    Dang S; Gao X; Ma G; Yu N; Han D; Yang Q; Tian X; Duan H
    Magn Reson Imaging; 2019 Apr; 57():271-276. PubMed ID: 30557591
    [TBL] [Abstract][Full Text] [Related]  

  • 37. CS-VIBE accelerates cranial nerve MR imaging for the diagnosis of facial neuritis: comparison of the diagnostic performance of post-contrast MPRAGE and CS-VIBE.
    Chung MS; Yim Y; Sung JK; Kim I; Nickel D; Chang M; Mun SK; Byun JS
    Eur Radiol; 2022 Jan; 32(1):223-233. PubMed ID: 34156555
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Clinical application of 3D VIBECAIPI-DIXON for non-enhanced imaging of the pancreas compared to a standard 2D fat-saturated FLASH.
    Haneder S; Koziel K; Morelli JN; Riffel P; Budjan J; Schoenberg SO; Michaely HJ
    Clin Imaging; 2014; 38(2):142-7. PubMed ID: 24332974
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Diagnostic Accuracy of High-Resolution Black-Blood MRI in the Evaluation of Intracranial Large-Vessel Arterial Occlusions.
    Al-Smadi AS; Abdalla RN; Elmokadem AH; Shaibani A; Hurley MC; Potts MB; Jahromi BS; Carroll TJ; Ansari SA
    AJNR Am J Neuroradiol; 2019 Jun; 40(6):954-959. PubMed ID: 31072969
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Comparison between postcontrast thin-slice T1-weighted 2D spin echo and 3D T1-weighted SPACE sequences in the detection of brain metastases at 1.5 and 3 T.
    Vymazal J; Ryznarova Z; Rulseh AM
    Insights Imaging; 2024 Mar; 15(1):73. PubMed ID: 38483648
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.