These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
119 related articles for article (PubMed ID: 36996983)
1. An electrochemical sensor based on synergistic enhancement effects between nitrogen-doped carbon nanotubes and copper ions for ultrasensitive determination of anti-diabetic metformin. Wu L; Lu X; Wu Y; Huang C; Gu C; Tian Y; Ma J Sci Total Environ; 2023 Jun; 878():163120. PubMed ID: 36996983 [TBL] [Abstract][Full Text] [Related]
2. Ultrasensitive and selective molecularly imprinted electrochemical oxaliplatin sensor based on a novel nitrogen-doped carbon nanotubes/Ag@cu MOF as a signal enhancer and reporter nanohybrid. Mahnashi MH; Mahmoud AM; Alhazzani K; Alanazi AZ; Alaseem AM; Algahtani MM; El-Wekil MM Mikrochim Acta; 2021 Mar; 188(4):124. PubMed ID: 33712895 [TBL] [Abstract][Full Text] [Related]
3. CuCo Wang Y; Yao L; Liu X; Cheng J; Liu W; Liu T; Sun M; Zhao L; Ding F; Lu Z; Zou P; Wang X; Zhao Q; Rao H Biosens Bioelectron; 2019 Oct; 142():111483. PubMed ID: 31279173 [TBL] [Abstract][Full Text] [Related]
4. Highly sensitive electrochemical detection of carbendazim residues in water by synergistic enhancement of nitrogen-doped carbon nanohorns and polyethyleneimine modified carbon nanotubes. Chen X; Li W; Lu C; Chu J; Lin R; Wang P; Xie G; Gu Q; Wu D; Chu B Sci Total Environ; 2022 Dec; 851(Pt 2):158324. PubMed ID: 36037905 [TBL] [Abstract][Full Text] [Related]
5. Nitrogen-doped carbon nanotubes decorated poly (L-Cysteine) as a novel, ultrasensitive electrochemical sensor for simultaneous determination of theophylline and caffeine. Wang Y; Ding Y; Li L; Hu P Talanta; 2018 Feb; 178():449-457. PubMed ID: 29136847 [TBL] [Abstract][Full Text] [Related]
6. Composite of Cu metal nanoparticles-multiwall carbon nanotubes-reduced graphene oxide as a novel and high performance platform of the electrochemical sensor for simultaneous determination of nitrite and nitrate. Bagheri H; Hajian A; Rezaei M; Shirzadmehr A J Hazard Mater; 2017 Feb; 324(Pt B):762-772. PubMed ID: 27894754 [TBL] [Abstract][Full Text] [Related]
7. Electrochemical sensing of copper (II) ion in water using bi-metal oxide framework modified glassy carbon electrode. Theerthagiri S; Rajkannu P; Senthil Kumar P; Peethambaram P; Ayyavu C; Rasu R; Kannaiyan D Food Chem Toxicol; 2022 Sep; 167():113313. PubMed ID: 35872257 [TBL] [Abstract][Full Text] [Related]
8. Fabrication of electrochemical sensor for paracetamol based on multi-walled carbon nanotubes and chitosan-copper complex by self-assembly technique. Mao A; Li H; Jin D; Yu L; Hu X Talanta; 2015 Nov; 144():252-7. PubMed ID: 26452818 [TBL] [Abstract][Full Text] [Related]
9. Electrochemical sensor applying ZrO Liu K; Pan M; Zhang Z; Hong L; Xie X; Yang J; Wang S; Wang Z; Song Y; Wang S Anal Chim Acta; 2022 Oct; 1231():340392. PubMed ID: 36220287 [TBL] [Abstract][Full Text] [Related]
10. A flow injection fluorescence "turn-on" sensor for the determination of metformin hydrochloride based on the inner filter effect of nitrogen-doped carbon dots/gold nanoparticles double-probe. Zhang GQ; Zhang XY; Luo YX; Li YS; Zhao Y; Gao XF Spectrochim Acta A Mol Biomol Spectrosc; 2021 Apr; 250():119384. PubMed ID: 33422879 [TBL] [Abstract][Full Text] [Related]
11. High-Performance Flexible Electrochemical Heavy Metal Sensor Based on Layer-by-Layer Assembly of Ti Hui X; Sharifuzzaman M; Sharma S; Xuan X; Zhang S; Ko SG; Yoon SH; Park JY ACS Appl Mater Interfaces; 2020 Oct; 12(43):48928-48937. PubMed ID: 33074662 [TBL] [Abstract][Full Text] [Related]
12. Differential pulse voltammetric determination of metformin using copper-loaded activated charcoal modified electrode. Gholivand MB; Mohammadi-Behzad L Anal Biochem; 2013 Jul; 438(1):53-60. PubMed ID: 23541522 [TBL] [Abstract][Full Text] [Related]
13. Copper (II)-ploy-L-histidine functionalized multi walled carbon nanotubes as efficient mimetic enzyme for sensitive electrochemical detection of salvianic acid A. Wang Z; Chen Y; Dong W; Zhou J; Han B; Jiao J; Lan L; Miao P; Chen Q Biosens Bioelectron; 2018 Dec; 121():257-264. PubMed ID: 30223101 [TBL] [Abstract][Full Text] [Related]
14. Novel tungsten phosphide embedded nitrogen-doped carbon nanotubes: A portable and renewable monitoring platform for anticancer drug in whole blood. Zhou H; Ran G; Masson JF; Wang C; Zhao Y; Song Q Biosens Bioelectron; 2018 May; 105():226-235. PubMed ID: 29412947 [TBL] [Abstract][Full Text] [Related]
15. Bifunctional Nitrogen and Fluorine Co-Doped Carbon Dots for Selective Detection of Copper and Sulfide Ions in Real Water Samples. Zeng Y; Xu Z; Guo J; Yu X; Zhao P; Song J; Qu J; Chen Y; Li H Molecules; 2022 Aug; 27(16):. PubMed ID: 36014385 [TBL] [Abstract][Full Text] [Related]
16. Synthesis of Fe-Cu/TiO₂ nanostructure and its use in construction of a sensitive and selective sensor for metformin determination. Gholivand MB; Shamsipur M; Paimard G; Feyzi M; Jafari F Mater Sci Eng C Mater Biol Appl; 2014 Sep; 42():791-8. PubMed ID: 25063181 [TBL] [Abstract][Full Text] [Related]
17. Determination of metformin based on amplification of its voltammetric response by a combination of molecular wire and carbon nanotubes. Tian XJ; Song JF; Luan XJ; Wang YY; Shi QZ Anal Bioanal Chem; 2006 Dec; 386(7-8):2081-6. PubMed ID: 17089101 [TBL] [Abstract][Full Text] [Related]
18. Simultaneous voltammetric determination of cadmium(II), lead(II), mercury(II), zinc(II), and copper(II) using a glassy carbon electrode modified with magnetite (Fe Wu W; Jia M; Wang Z; Zhang W; Zhang Q; Liu G; Zhang Z; Li P Mikrochim Acta; 2019 Jan; 186(2):97. PubMed ID: 30631955 [TBL] [Abstract][Full Text] [Related]
19. High-Performance, Nitrogen-Doped, Carbon-Nanotube-Based Electrochemical Sensor For Vitamin D3 Detection. Bora H; Mandal D; Chandra A ACS Appl Bio Mater; 2022 Apr; 5(4):1721-1730. PubMed ID: 35352938 [TBL] [Abstract][Full Text] [Related]