These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
132 related articles for article (PubMed ID: 37005766)
1. Performance Evaluation of a New Fluorescent-Based Lateral Flow Immunoassay for Quantification of Hemoglobin A1c (HBA1c) in Diabetic Patients. Younes N; Ghwairi MMA; Da'as SI; Zaabi EA; Majdalawieh AF; Al-Dewik N; Nasrallah GK Front Biosci (Landmark Ed); 2023 Mar; 28(3):60. PubMed ID: 37005766 [TBL] [Abstract][Full Text] [Related]
2. High-sensitive detection and quantitation of thyroid-stimulating hormone (TSH) from capillary/fingerstick and venepuncture whole-blood using fluorescence-based rapid lateral flow immunoassay (LFIA). Shurbaji S; Al Tamimi F; Al Ghwairi MM; El Chaar D; Younes S; Majdalawieh AF; Pintus G; Al-Dewik N; Nasrallah GK Heliyon; 2023 Oct; 9(10):e20589. PubMed ID: 37842620 [TBL] [Abstract][Full Text] [Related]
3. Accuracy and Precision of a Point-of-Care HbA1c Test. Arnold WD; Kupfer K; Little RR; Amar M; Horowitz B; Godbole N; Hvidsten Swensen M; Li Y; San George RC J Diabetes Sci Technol; 2020 Sep; 14(5):883-889. PubMed ID: 30854894 [TBL] [Abstract][Full Text] [Related]
4. Fingerstick Precision and Total Error of a Point-of-Care HbA1c Test. Arnold WD; Kupfer K; Hvidsten Swensen M; Fortner KS; Bays HE; Davis M; Klaff LJ; San George RC J Diabetes Sci Technol; 2020 Sep; 14(5):890-895. PubMed ID: 30841743 [TBL] [Abstract][Full Text] [Related]
5. Comparative Analytical Performance of Various HbA1c Assays in Iran. Razi F; Rahnamaye Farzami M; Ebrahimi SA; Nahid M; Bigdeli MG; Sheidaei A; Ghasemian A; Tootee A; Keramati T; Nasli Esfahani E; Larijani B; Pasalar P Arch Iran Med; 2016 Jun; 19(6):414-9. PubMed ID: 27293057 [TBL] [Abstract][Full Text] [Related]
6. A high-throughput test for diabetes care: An evaluation of the next generation Roche Cobas c 513 hemoglobin A Gifford JL; Higgins T; Sadrzadeh SMH Pract Lab Med; 2019 Nov; 17():e00147. PubMed ID: 31799362 [TBL] [Abstract][Full Text] [Related]
7. Prospective evaluation of accuracy, precision, and reproducibility of an at-home hemoglobin A1c sampling kit. Parkes J; Ray R; Kerestan S; Davis H; Ginsberg B Diabetes Technol Ther; 1999; 1(4):411-9. PubMed ID: 11474825 [TBL] [Abstract][Full Text] [Related]
8. Evaluation of HbA1c on the Roche COBAS Integra 800 closed tube system. Fleming JK Clin Biochem; 2007 Jul; 40(11):822-7. PubMed ID: 17555737 [TBL] [Abstract][Full Text] [Related]
9. Standardization of two immunological HbA1c routine assays according to the new IFCC reference method. Groche D; Hoeno W; Hoss G; Vogt B; Herrmann Z; Witzigmann A Clin Lab; 2003; 49(11-12):657-61. PubMed ID: 14651337 [TBL] [Abstract][Full Text] [Related]
10. Accuracy of point-of-care HbA1c testing in pregnant women. Culliney K; McCowan LME; Okesene-Gafa K; Murphy R; Rowan J; Taylor RS; Mckinlay CJD; Aust N Z J Obstet Gynaecol; 2018 Dec; 58(6):643-647. PubMed ID: 29468638 [TBL] [Abstract][Full Text] [Related]
11. Performance of the Roche second generation hemoglobin A1c immunoassay in the presence of HB-S or HB-C traits. Abadie JM; Koelsch AA Ann Clin Lab Sci; 2008; 38(1):31-6. PubMed ID: 18316779 [TBL] [Abstract][Full Text] [Related]
12. Multicenter evaluation of hemoglobin A1c assay on capillary electrophoresis. Marinova M; Altinier S; Caldini A; Passerini G; Pizzagalli G; Brogi M; Zaninotto M; Ceriotti F; Plebani M Clin Chim Acta; 2013 Sep; 424():207-11. PubMed ID: 23792069 [TBL] [Abstract][Full Text] [Related]
13. Performance evaluation of novel fluorescent-based lateral flow immunoassay (LFIA) for rapid detection and quantification of total anti-SARS-CoV-2 S-RBD binding antibodies in infected individuals. Shurrab FM; Younes N; Al-Sadeq DW; Liu N; Qotba H; Abu-Raddad LJ; Nasrallah GK Int J Infect Dis; 2022 May; 118():132-137. PubMed ID: 35231609 [TBL] [Abstract][Full Text] [Related]
14. A comparative evaluation of the analytical performances of Capillarys 2 Flex Piercing, Tosoh HLC-723 G8, Premier Hb9210, and Roche Cobas c501 Tina-quant Gen 2 analyzers for HbA Wu X; Chao Y; Wan Z; Wang Y; Ma Y; Ke P; Wu X; Xu J; Zhuang J; Huang X Biochem Med (Zagreb); 2016 Oct; 26(3):353-364. PubMed ID: 27812304 [TBL] [Abstract][Full Text] [Related]
15. Japanese standard reference material JDS Lot 2 for haemoglobin A1c. II: Present state of standardization of haemoglobin A1c in Japan using the new reference material in routine clinical assays. Tominaga M; Makino H; Yoshino G; Kuwa K; Takei I; Aono Y; Hoshino T; Umemoto M; Shimatsu A; Sanke T; Kuwashima M; Taminato T; Ono J Ann Clin Biochem; 2005 Jan; 42(Pt 1):47-50. PubMed ID: 15802032 [TBL] [Abstract][Full Text] [Related]
17. Direct monitoring of glycohemoglobin A1c in the blood samples of diabetic patients by capillary electrophoresis. Comparison with an immunoassay method. Sirén H; Laitinen P; Turpeinen U; Karppinen P J Chromatogr A; 2002 Dec; 979(1-2):201-7. PubMed ID: 12498249 [TBL] [Abstract][Full Text] [Related]
18. Japanese standard reference material for JDS Lot 2 haemoglobin A1c. I: Comparison of Japan Diabetes Society-assigned values to those obtained by the Japanese and USA domestic standardization programmes and by the International Federation of Clinical Chemistry reference laboratories. Tominaga M; Makino H; Yoshino G; Kuwa K; Takei I; Aono Y; Hoshino T; Umemoto M; Shimatsu A; Sanke T; Kuwashima M; Taminato T; Ono J Ann Clin Biochem; 2005 Jan; 42(Pt 1):41-6. PubMed ID: 15802031 [TBL] [Abstract][Full Text] [Related]
19. Analytical performance evaluation of the Mindray enzymatic assay for hemoglobin A Li M; Wu X; Xie W; Zeng Y; Wang H; Chen H; Xu A; Liu H; Ji L Sci Rep; 2024 May; 14(1):12289. PubMed ID: 38811684 [TBL] [Abstract][Full Text] [Related]