These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
119 related articles for article (PubMed ID: 37012805)
1. Design and first measurements of the fast-ion D-alpha diagnostic at the HL-2A tokamak. Hou YM; Zhou HY; Chen W; Hao BL; Liu Y; Shi ZB; Zhang YP; Duan XR Rev Sci Instrum; 2023 Mar; 94(3):033508. PubMed ID: 37012805 [TBL] [Abstract][Full Text] [Related]
2. Fast-ion Dα measurements of the fast-ion distribution (invited). Heidbrink WW Rev Sci Instrum; 2010 Oct; 81(10):10D727. PubMed ID: 21033920 [TBL] [Abstract][Full Text] [Related]
3. Fast-ion D Yoo JW; Kim J; Lee MW; Kang J; Ko WH; Oh SG; Ko J; Lee JH; Nam YU; Jung L; Park BH; Yoon SW Rev Sci Instrum; 2021 Apr; 92(4):043504. PubMed ID: 34243446 [TBL] [Abstract][Full Text] [Related]
4. Validation of fast-ion D-alpha spectrum measurements during EAST neutral-beam heated plasmas. Huang J; Heidbrink WW; von Hellermann MG; Stagner L; Wu CR; Hou YM; Chang JF; Ding SY; Chen YJ; Zhu YB; Jin Z; Xu Z; Gao W; Wang JF; Lyu B; Zang Q; Zhong GQ; Hu L; Wan B; Rev Sci Instrum; 2016 Nov; 87(11):11E542. PubMed ID: 27910390 [TBL] [Abstract][Full Text] [Related]
5. First fast-ion D-alpha (FIDA) measurements and simulations on C-2U. Bolte NG; Gupta D; Stagner L; Onofri M; Dettrick S; Granstedt EM; Petrov P Rev Sci Instrum; 2016 Nov; 87(11):11E520. PubMed ID: 27910688 [TBL] [Abstract][Full Text] [Related]
6. Diagnosis of fast ions produced by negative-ion neutral-beam injection with fast-ion deuterium-alpha spectroscopy. Muscatello CM; Heidbrink WW; Boivin RL; Chrystal C; Collins CS; Fujiwara Y; Yamaguchi H Rev Sci Instrum; 2019 Jul; 90(7):073504. PubMed ID: 31370451 [TBL] [Abstract][Full Text] [Related]
7. Development and signals simulation of a diamond detector neutral particle analyzer on Huanliu-2A (HL-2A) tokamak. Qu YF; Zang LG; Chen W; Hou YM; Lu J; Luo Y Rev Sci Instrum; 2022 Nov; 93(11):113507. PubMed ID: 36461440 [TBL] [Abstract][Full Text] [Related]
8. A tangentially viewing fast ion D-alpha diagnostic for NSTX. Bortolon A; Heidbrink WW; Podestà M Rev Sci Instrum; 2010 Oct; 81(10):10D728. PubMed ID: 21033921 [TBL] [Abstract][Full Text] [Related]
10. Fast ion D-alpha measurements using a bandpass-filtered system on EAST. Zhang J; Huang J; Chang JF; Wu CR; Heidbrink WW; Salewski M; Madsen B; Zhu YB; von Hellermann MG; Gao W; Xu Z; Wan B Rev Sci Instrum; 2018 Oct; 89(10):10D121. PubMed ID: 30399922 [TBL] [Abstract][Full Text] [Related]
11. High speed fast-ion D-alpha spectrometer for the NSTX-U tokamak. Edmondson A; Albosta R; Geiger B; Gallenberger T; Smith D; Heidbrink WW; Stratton B Rev Sci Instrum; 2024 Sep; 95(9):. PubMed ID: 39292158 [TBL] [Abstract][Full Text] [Related]
12. The imaging fast ion D-alpha diagnostic (IFIDA) on DIII-D. Marini C; Collins CS; Van Zeeland MA; Thome KE; Heidbrink WW; Lin D Rev Sci Instrum; 2021 Mar; 92(3):033533. PubMed ID: 33819993 [TBL] [Abstract][Full Text] [Related]
13. Fast-ion D-alpha diagnostic development for the C-2W field-reversed configuration plasma. Bolte NG; Nations M; Gupta D; Aviles J; Rev Sci Instrum; 2018 Oct; 89(10):10D106. PubMed ID: 30399950 [TBL] [Abstract][Full Text] [Related]
14. Active spectroscopic measurements of the bulk deuterium properties in the DIII-D tokamak (invited). Grierson BA; Burrell KH; Chrystal C; Groebner RJ; Kaplan DH; Heidbrink WW; Muñoz Burgos JM; Pablant NA; Solomon WM; Van Zeeland MA Rev Sci Instrum; 2012 Oct; 83(10):10D529. PubMed ID: 23126869 [TBL] [Abstract][Full Text] [Related]
15. Charge exchange spectroscopy as a fast ion diagnostic on TEXTOR. Delabie E; Jaspers RJ; von Hellermann MG; Nielsen SK; Marchuk O Rev Sci Instrum; 2008 Oct; 79(10):10E522. PubMed ID: 19044504 [TBL] [Abstract][Full Text] [Related]
16. Measurement of the D alpha spectrum produced by fast ions in DIII-D. Luo Y; Heidbrink WW; Burrell KH; Kaplan DH; Gohil P Rev Sci Instrum; 2007 Mar; 78(3):033505. PubMed ID: 17411183 [TBL] [Abstract][Full Text] [Related]
17. First measurements of D(α) spectrum produced by anisotropic fast ions in the gas dynamic trap. Lizunov A; Anikeev A Rev Sci Instrum; 2014 Nov; 85(11):113110. PubMed ID: 25430101 [TBL] [Abstract][Full Text] [Related]
18. Development of the scintillator-based probe for fast-ion losses in the HL-2A tokamak. Zhang YP; Liu Y; Luo XB; Isobe M; Yuan GL; Liu YQ; Hua Y; Song XY; Yang JW; Li X; Chen W; Li Y; Yan LW; Song XM; Yang QW; Duan XR Rev Sci Instrum; 2014 May; 85(5):053502. PubMed ID: 24880364 [TBL] [Abstract][Full Text] [Related]
19. Multi-view fast-ion D-alpha spectroscopy diagnostic at ASDEX Upgrade. Geiger B; Dux R; McDermott RM; Potzel S; Reich M; Ryter F; Weiland M; Wünderlich D; ; Garcia-Munoz M Rev Sci Instrum; 2013 Nov; 84(11):113502. PubMed ID: 24295435 [TBL] [Abstract][Full Text] [Related]
20. Note: Real-time wavelength matching system designed for the motional Stark effect polarimeter on HL-2A tokamak. Chen WJ; Yu DL; Yan LW; Yuan BS; He XX; Liu L; Wei YL; Wang J; Shi ZB; Liu Y; Yang QW Rev Sci Instrum; 2018 Dec; 89(12):126103. PubMed ID: 30599558 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]