These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

113 related articles for article (PubMed ID: 37015541)

  • 1. Convex Combination of Images From Dual-Layer Detectors for High Detective Quantum Efficiencies.
    Kim DS
    IEEE Trans Biomed Eng; 2023 Jun; 70(6):1804-1814. PubMed ID: 37015541
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A detective quantum efficiency for spectroscopic X-ray imaging detectors.
    Tanguay J; Richtsmeier D; Dydula C; Day JA; Iniewski K; Bazalova-Carter M
    Med Phys; 2021 Nov; 48(11):6781-6799. PubMed ID: 34460950
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Frequency-dependent optimal weighting approach for megavoltage multilayer imagers.
    Valencia Lozano I; Shi M; Myronakis M; Baturin P; Fueglistaller R; Huber P; Lehmann M; Morf D; Ferguson D; Jacobson MW; Harris T; Berbeco RI; Williams CL
    Phys Med Biol; 2021 Apr; 66(8):. PubMed ID: 33503603
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Development of a novel high quantum efficiency MV x-ray detector for image-guided radiotherapy: A feasibility study.
    Liu J; Xu Y; Teymurazyan A; Papandreou Z; Pang G
    Med Phys; 2020 Jan; 47(1):152-163. PubMed ID: 31682020
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Rapid Monte Carlo simulation of detector DQE(f).
    Star-Lack J; Sun M; Meyer A; Morf D; Constantin D; Fahrig R; Abel E
    Med Phys; 2014 Mar; 41(3):031916. PubMed ID: 24593734
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Technical Note: Detective quantum efficiency simulation of a-Se imaging detectors using ARTEMIS.
    Fang Y; Ito T; Nariyuki F; Kuwabara T; Badano A; Karim KS
    Med Phys; 2017 Aug; 44(8):4035-4039. PubMed ID: 28569992
    [TBL] [Abstract][Full Text] [Related]  

  • 7. MTF and DQE enhancement using an apodized-aperture x-ray detector design.
    Nano TF; Escartin T; Ismailova E; Karim KS; Lindström J; Kim HK; Cunningham IA
    Med Phys; 2017 Sep; 44(9):4525-4535. PubMed ID: 28636792
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The detective quantum efficiency of cadmium telluride photon-counting x-ray detectors in breast imaging applications.
    Day JA; Tanguay J
    Med Phys; 2022 Mar; 49(3):1481-1494. PubMed ID: 34905627
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Segmented crystalline scintillators: empirical and theoretical investigation of a high quantum efficiency EPID based on an initial engineering prototype CsI(TI) detector.
    Sawant A; Antonuk LE; El-Mohri Y; Zhao Q; Wang Y; Li Y; Du H; Perna L
    Med Phys; 2006 Apr; 33(4):1053-66. PubMed ID: 16696482
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Monte Carlo performance on the x-ray converter thickness in digital mammography using software breast models.
    Liaparinos P; Bliznakova K
    Med Phys; 2012 Nov; 39(11):6638-51. PubMed ID: 23127058
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Direct conversion detectors: the effect of incomplete charge collection on detective quantum efficiency.
    Mainprize JG; Hunt DC; Yaffe MJ
    Med Phys; 2002 Jun; 29(6):976-90. PubMed ID: 12094993
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Nonstationary model of oblique x-ray incidence in amorphous selenium detectors: II. Transfer functions.
    Acciavatti RJ; Maidment ADA
    Med Phys; 2019 Feb; 46(2):505-516. PubMed ID: 30488455
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Overestimations in zero frequency DQE of x-ray imaging converters assessed by Monte Carlo techniques based on the study of energy impartation events.
    Liaparinos PF; Kandarakis IS
    Med Phys; 2011 Jul; 38(7):4440-50. PubMed ID: 21859045
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Modeling the frequency-dependent detective quantum efficiency of photon-counting x-ray detectors.
    Stierstorfer K
    Med Phys; 2018 Jan; 45(1):156-166. PubMed ID: 29131361
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Investigation of combined kV/MV CBCT imaging with a high-DQE MV detector.
    Lindsay C; Bazalova-Carter M; Wang A; Shedlock D; Wu M; Newson M; Xing L; Ansbacher W; Fahrig R; Star-Lack J
    Med Phys; 2019 Feb; 46(2):563-575. PubMed ID: 30428131
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A comparative analysis of OTF, NPS, and DQE in energy integrating and photon counting digital x-ray detectors.
    Acciavatti RJ; Maidment AD
    Med Phys; 2010 Dec; 37(12):6480-95. PubMed ID: 21302803
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Digital radiology using active matrix readout of amorphous selenium: theoretical analysis of detective quantum efficiency.
    Zhao W; Rowlands JA
    Med Phys; 1997 Dec; 24(12):1819-33. PubMed ID: 9434965
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Measurement of the detective quantum efficiency (DQE) of digital X-ray detectors according to the novel standard IEC 62220-1.
    Illers H; Buhr E; Hoeschen C
    Radiat Prot Dosimetry; 2005; 114(1-3):39-44. PubMed ID: 15933079
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Technical Note: Impact on detective quantum efficiency of edge angle determination method by International Electrotechnical Commission methodology for cardiac x-ray image detectors.
    Gislason-Lee AJ; Tunstall CM; Kengyelics SK; Cowen AR; Davies AG
    Med Phys; 2015 Aug; 42(8):4423-7. PubMed ID: 26233172
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fundamental x-ray interaction limits in diagnostic imaging detectors: frequency-dependent Swank noise.
    Hajdok G; Battista JJ; Cunningham IA
    Med Phys; 2008 Jul; 35(7):3194-204. PubMed ID: 18697544
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.