These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 3702346)

  • 1. The analysis of ethanol in serum, blood, and urine: a comparison of the TDx REA ethanol assay with gas chromatography.
    Caplan YH; Levine B
    J Anal Toxicol; 1986; 10(2):49-52. PubMed ID: 3702346
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of the Abbott TDx-radiative energy attenuation (REA) ethanol assay in a study of 1105 forensic whole blood specimens.
    Caplan YH; Levine B
    J Forensic Sci; 1987 Jan; 32(1):55-61. PubMed ID: 3819689
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Abbott radiative energy attenuation method for quantifying ethanol evaluated and compared with gas-liquid chromatography and the Du Pont aca.
    Cary PL; Whitter PD; Johnson CA
    Clin Chem; 1984 Nov; 30(11):1867-70. PubMed ID: 6386230
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Use of the ADH/REA method (Abbott Tdx-REA) in forensic blood alcohol determination].
    Mebs D; Schmidt K; Bratzke H
    Blutalkohol; 1996 Mar; 33(2):71-7. PubMed ID: 8679135
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of the ADx REA assay for determination of ethanol in serum and urine.
    Jortani SA; Poklis A
    J Anal Toxicol; 1993 Sep; 17(5):307-9. PubMed ID: 8107467
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of the Abbott TDx for determination of phenobarbital in forensic blood specimens.
    Marker EK; Krasselt WG; Mueggler PA
    J Anal Toxicol; 1987; 11(6):257-9. PubMed ID: 3431094
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of the Abbott ADx and TDx serum benzodiazepine immunoassays for analysis of alprazolam.
    Fraser AD; Bryan W
    J Anal Toxicol; 1991; 15(2):63-5. PubMed ID: 1675703
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Factors influencing ethanol determination in urine using the TDx system].
    Graw M; Besserer K
    Beitr Gerichtl Med; 1989; 47():391-6. PubMed ID: 2818508
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A comparison of a microdiffusion method for ethanol and the Abbott TDx ethanol assay.
    Serrano L; Capshaw B; Quattrocchi F
    J Anal Toxicol; 1988; 12(6):348-9. PubMed ID: 3072450
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A comparison of a commercial microdiffusion method and gas chromatography for ethanol analysis.
    Cox RA; Crifasi JA
    J Anal Toxicol; 1990; 14(4):211-2. PubMed ID: 2395339
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Application of the Abbott TDx lidocaine, phenytoin, and phenobarbital assays to postmortem blood specimens.
    Caplan YH; Levine B
    J Anal Toxicol; 1988; 12(5):265-7. PubMed ID: 3066993
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Highly sensitive gas chromatographic analysis of ethanol in whole blood, serum, urine, and fecal supernatants by the direct injection method.
    Tangerman A
    Clin Chem; 1997 Jun; 43(6 Pt 1):1003-9. PubMed ID: 9191553
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effect of biologic specimen type on the gas chromatographic headspace analysis of ethanol and other volatile compounds.
    Watts MT; McDonald OL
    Am J Clin Pathol; 1987 Jan; 87(1):79-85. PubMed ID: 3799546
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Use of a competitive inhibitor in a kinetic enzymatic method for measuring ethanol in serum.
    Young E; Rafter-Tadgell B
    Clin Chem; 1987 Dec; 33(12):2296-8. PubMed ID: 3690849
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparative study of ethanol levels in blood versus bone marrow, vitreous humor, bile and urine.
    Winek CL; Esposito FM
    Forensic Sci Int; 1981; 17(1):27-36. PubMed ID: 7216079
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Emit ETS plus ethyl alcohol assay for the determination of ethanol in human serum and urine.
    Jortani SA; Poklis A
    J Anal Toxicol; 1992; 16(6):368-71. PubMed ID: 1293403
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of the Abbott TDx analyzer.
    Lee CW; Lee HM
    J Anal Toxicol; 1989; 13(1):50-6. PubMed ID: 2651803
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Simultaneous Determination of Methanol, Ethanol and Formic Acid in Serum and Urine by Headspace GC-FID.
    Bursová M; Hložek T; Čabala R
    J Anal Toxicol; 2015; 39(9):741-5. PubMed ID: 26178163
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparative evaluation of the Abbott TDX, the Abbott ABA200, and the Syva LAB5000 for assay of serum gentamicin.
    Cheng AF; Lam AW; French GL
    J Antimicrob Chemother; 1987 Jan; 19(1):127-33. PubMed ID: 3549667
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Conversion coefficients in quantitative determination of ethyl alcohol in blood and urine by the method of gas-liquid chromatography].
    Romanova AA
    Sud Med Ekspert; 1974; 17(4):11-2. PubMed ID: 4450233
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.