BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

198 related articles for article (PubMed ID: 37024103)

  • 1. Lower Extremity Inverse Kinematics Results Differ Between Inertial Measurement Unit- and Marker-Derived Gait Data.
    Hafer JF; Mihy JA; Hunt A; Zernicke RF; Johnson RT
    J Appl Biomech; 2023 Jun; 39(3):133-142. PubMed ID: 37024103
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Measuring markers of aging and knee osteoarthritis gait using inertial measurement units.
    Hafer JF; Provenzano SG; Kern KL; Agresta CE; Grant JA; Zernicke RF
    J Biomech; 2020 Jan; 99():109567. PubMed ID: 31916999
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Validity Evaluation of an Inertial Measurement Unit (IMU) in Gait Analysis Using Statistical Parametric Mapping (SPM).
    Park S; Yoon S
    Sensors (Basel); 2021 May; 21(11):. PubMed ID: 34070344
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Validity of Inertial Measurement Units to Measure Lower-Limb Kinematics and Pelvic Orientation at Submaximal and Maximal Effort Running Speeds.
    Lin YC; Price K; Carmichael DS; Maniar N; Hickey JT; Timmins RG; Heiderscheit BC; Blemker SS; Opar DA
    Sensors (Basel); 2023 Dec; 23(23):. PubMed ID: 38067972
    [TBL] [Abstract][Full Text] [Related]  

  • 5. OpenSense: An open-source toolbox for inertial-measurement-unit-based measurement of lower extremity kinematics over long durations.
    Al Borno M; O'Day J; Ibarra V; Dunne J; Seth A; Habib A; Ong C; Hicks J; Uhlrich S; Delp S
    J Neuroeng Rehabil; 2022 Feb; 19(1):22. PubMed ID: 35184727
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Inertial Sensor-to-Segment Calibration for Accurate 3D Joint Angle Calculation for Use in OpenSim.
    Di Raimondo G; Vanwanseele B; van der Have A; Emmerzaal J; Willems M; Killen BA; Jonkers I
    Sensors (Basel); 2022 Apr; 22(9):. PubMed ID: 35590949
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Validation of wearable inertial sensor-based gait analysis system for measurement of spatiotemporal parameters and lower extremity joint kinematics in sagittal plane.
    Patel G; Mullerpatan R; Agarwal B; Shetty T; Ojha R; Shaikh-Mohammed J; Sujatha S
    Proc Inst Mech Eng H; 2022 May; 236(5):686-696. PubMed ID: 35001713
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Real-time conversion of inertial measurement unit data to ankle joint angles using deep neural networks.
    Senanayake D; Halgamuge S; Ackland DC
    J Biomech; 2021 Aug; 125():110552. PubMed ID: 34237661
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of Error-State Kalman Filter Method for Estimating Human Lower-Limb Kinematics during Various Walking Gaits.
    Potter MV; Cain SM; Ojeda LV; Gurchiek RD; McGinnis RS; Perkins NC
    Sensors (Basel); 2022 Nov; 22(21):. PubMed ID: 36366096
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Optimization of IMU Sensor Placement for the Measurement of Lower Limb Joint Kinematics.
    Niswander W; Wang W; Kontson K
    Sensors (Basel); 2020 Oct; 20(21):. PubMed ID: 33105876
    [TBL] [Abstract][Full Text] [Related]  

  • 11. IMUs Can Estimate Hip and Knee Range of Motion during Walking Tasks but Are Not Sensitive to Changes in Load or Grade.
    Fain A; McCarthy A; Nindl BC; Fuller JT; Wills JA; Doyle TLA
    Sensors (Basel); 2024 Mar; 24(5):. PubMed ID: 38475210
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Sagittal plane knee kinematics can be measured during activities of daily living following total knee arthroplasty with two IMU.
    Cornish BM; Diamond LE; Saxby DJ; Lloyd DG; Shi B; Lyon J; Abbruzzese K; Gallie P; Maharaj J
    PLoS One; 2024; 19(2):e0297899. PubMed ID: 38359050
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Using Inertial Measurement Unit Sensor Single Axis Rotation Angles for Knee and Hip Flexion Angle Calculations During Gait.
    Oliveira N; Park J; Barrance P
    IEEE J Transl Eng Health Med; 2023; 11():80-86. PubMed ID: 36704243
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Propulsive joint powers track with sensor-derived angular velocity: A potential tool for lab-less gait retraining.
    Hafer JF; Zernicke RF
    J Biomech; 2020 Jun; 106():109821. PubMed ID: 32517990
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Concurrent validity and within-session reliability of gait kinematics measured using an inertial motion capture system with repeated calibration.
    Berner K; Cockcroft J; Morris LD; Louw Q
    J Bodyw Mov Ther; 2020 Oct; 24(4):251-260. PubMed ID: 33218520
    [TBL] [Abstract][Full Text] [Related]  

  • 16. DeepBBWAE-Net: A CNN-RNN Based Deep SuperLearner for Estimating Lower Extremity Sagittal Plane Joint Kinematics Using Shoe-Mounted IMU Sensors in Daily Living.
    Hossain MSB; Dranetz J; Choi H; Guo Z
    IEEE J Biomed Health Inform; 2022 Aug; 26(8):3906-3917. PubMed ID: 35385394
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Open-source software library for real-time inertial measurement unit data-based inverse kinematics using OpenSim.
    Lavikainen J; Vartiainen P; Stenroth L; Karjalainen PA
    PeerJ; 2023; 11():e15097. PubMed ID: 37038471
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The contribution of multibody optimization when using inertial measurement units to compute lower-body kinematics.
    Pacher L; Vignais N; Chatellier C; Vauzelle R; Fradet L
    Med Eng Phys; 2023 Jan; 111():103927. PubMed ID: 36792234
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Inertial motion capture validation of 3D knee kinematics at various gait speed on the treadmill with a double-pose calibration.
    Robert-Lachaine X; Parent G; Fuentes A; Hagemeister N; Aissaoui R
    Gait Posture; 2020 Mar; 77():132-137. PubMed ID: 32035296
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Body-Worn IMU-Based Human Hip and Knee Kinematics Estimation during Treadmill Walking.
    McGrath T; Stirling L
    Sensors (Basel); 2022 Mar; 22(7):. PubMed ID: 35408159
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.