These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

149 related articles for article (PubMed ID: 37031902)

  • 1. Agreement of LC-MS assays for IGF-1 traceable to NIST and WHO standards permits harmonization of reference intervals between laboratories.
    Ezra S; Winstone TML; Singh R; Orton DJ
    Clin Biochem; 2023 Jun; 116():75-78. PubMed ID: 37031902
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Bias in IGF-1 concentrations and interpretation across three different clinical laboratory assays.
    Mohammed-Ali Z; Delaney S; Singh R; Leung F; Taher J; Goguen J; Gilmour J; Sepiashvili L; Beriault DR
    Clin Biochem; 2022 Oct; 108():14-19. PubMed ID: 35772500
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Discordance of insulin-like growth factor-1 results and interpretation on four different platforms.
    Lee JKY; Cradic K; Singh RJ; Jones J; Li J
    Clin Chim Acta; 2023 Jan; 539():130-133. PubMed ID: 36528048
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of Immunoassay and Liquid Chromatography-Tandem Mass Spectrometry Methods in the Measurement of Serum Androstenedione Levels.
    Yucel K; Abusoglu S; Unlu A
    Clin Lab; 2018 Jan; 64(1):69-75. PubMed ID: 29479885
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An antibody-free LC-MS/MS method for the quantification of intact insulin-like growth factors 1 and 2 in human plasma.
    Pratt MS; van Faassen M; Remmelts N; Bischoff R; Kema IP
    Anal Bioanal Chem; 2021 Mar; 413(8):2035-2044. PubMed ID: 33569646
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of the analytical performance of Unicel DXI 800 for the Total 25 (OH) Vitamin D measurements.
    Ozcan N; Ucar F; Arzuhal AE; Bulut E; Ozturk A; Taslipinar Yavuz M; Temel I; Erden G
    Clin Biochem; 2016 Apr; 49(6):486-491. PubMed ID: 26655254
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A high-throughput assay for the quantification of intact Insulin-like Growth Factor I in human serum using online SPE-LC-HRMS.
    Coppieters G; Judák P; Van Haecke N; Van Renterghem P; Van Eenoo P; Deventer K
    Clin Chim Acta; 2020 Nov; 510():391-399. PubMed ID: 32739215
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Performance characteristics of the VIDAS® 25-OH Vitamin D Total assay - comparison with four immunoassays and two liquid chromatography-tandem mass spectrometry methods in a multicentric study.
    Moreau E; Bächer S; Mery S; Le Goff C; Piga N; Vogeser M; Hausmann M; Cavalier E
    Clin Chem Lab Med; 2016 Jan; 54(1):45-53. PubMed ID: 26124054
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Performance evaluation of four 25-hydroxyvitamin D assays to measure 25-hydroxyvitamin D2.
    Freeman J; Wilson K; Spears R; Shalhoub V; Sibley P
    Clin Biochem; 2015 Nov; 48(16-17):1097-104. PubMed ID: 26054580
    [TBL] [Abstract][Full Text] [Related]  

  • 10. CLSI-based transference and verification of CALIPER pediatric reference intervals for 29 Ortho VITROS 5600 chemistry assays.
    Higgins V; Truong D; Woroch A; Chan MK; Tahmasebi H; Adeli K
    Clin Biochem; 2018 Mar; 53():93-103. PubMed ID: 29307782
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Multicenter Evaluation of a New, Fully Automated Androstenedione Electrochemiluminescence Immunoassay: Precision Analysis, Method Comparison, and Determination of Reference Ranges.
    Obermayer-Pietsch B; de Ramon M; Reichmuth C; Bendig G; Hutzler S; Taibon J; Rank CM; Findeisen P
    J Appl Lab Med; 2022 Mar; 7(2):503-514. PubMed ID: 34662384
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of the Serum Total 25-Hydroxyvitamin D Concentrations Using Chemiluminescent Immunoassay and Liquid Chromatography-Tandem Mass Spectrometry in Children.
    Wang J; Li X; Gan Y; Fan T; Yang J; Rao F; Yang J
    J Nutr Sci Vitaminol (Tokyo); 2022; 68(3):181-188. PubMed ID: 35768249
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of four different immunoassays and a rapid isotope-dilution liquid chromatography-tandem mass spectrometry assay for serum folate.
    Jin L; Lu Y; Yi X; Zhang M; Zhang J; Zhou W; Zeng J; Zhang T; Zhang C
    Clin Chem Lab Med; 2022 Aug; 60(9):1393-1402. PubMed ID: 35675883
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Estimating testosterone concentrations in adolescent girls: Comparison of two direct immunoassays to liquid chromatography-tandem mass spectrometry.
    McCartney CR; Burt Solorzano CM; Patrie JT; Marshall JC; Haisenleder DJ
    Steroids; 2018 Dec; 140():62-69. PubMed ID: 30217784
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The impact of different calibration matrices on the determination of insulin-like growth factor 1 by high-resolution-LC-MS in acromegalic and growth hormone deficient patients.
    Simstich S; Züllig T; D'Aurizio F; Biasotto A; Colao A; Isidori AM; Lenzi A; Fauler G; Köfeler HC; Curcio F; Herrmann M
    Clin Biochem; 2023 Apr; 114():95-102. PubMed ID: 36849049
    [TBL] [Abstract][Full Text] [Related]  

  • 16. State-of-the-art of serum testosterone measurement by isotope dilution-liquid chromatography-tandem mass spectrometry.
    Thienpont LM; Van Uytfanghe K; Blincko S; Ramsay CS; Xie H; Doss RC; Keevil BG; Owen LJ; Rockwood AL; Kushnir MM; Chun KY; Chandler DW; Field HP; Sluss PM
    Clin Chem; 2008 Aug; 54(8):1290-7. PubMed ID: 18556330
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Inter-Laboratory Agreement of Insulin-like Growth Factor 1 Concentrations Measured Intact by Mass Spectrometry.
    Moncrieffe D; Cox HD; Carletta S; Becker JO; Thomas A; Eichner D; Ahrens B; Thevis M; Bowers LD; Cowan DA; Hoofnagle AN
    Clin Chem; 2020 Apr; 66(4):579-586. PubMed ID: 32232452
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of everolimus QMS immunoassay on Architect ci4100 and liquid chromatography/mass spectrometry: lack of agreement in organ-transplanted patients.
    Hoffer E; Kurnik D; Efrati E; Scherb I; Karasik M; Ring G; Bentur Y
    Ther Drug Monit; 2015 Apr; 37(2):214-9. PubMed ID: 25162218
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A multicenter performance evaluation of the new Elecsys Vitamin D total III assay versus reference isotope dilution liquid chromatography tandem mass spectrometry and commercially available comparators.
    Findeisen P; Leis M; Bendig G; Grimme J; Moser E; Vogl C; Christenson R
    J Clin Lab Anal; 2022 Sep; 36(9):e24610. PubMed ID: 35852988
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Total serum vitamin B12 (cobalamin) LC-MS/MS assay as an arbiter of clinically discordant immunoassay results.
    Zhang R; Ma X; Zou Y; Qiu L; Wang D; Tang Y; Cao Y; Yu S; Cheng X
    Clin Chem Lab Med; 2023 Jan; 61(1):86-92. PubMed ID: 36103653
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.