190 related articles for article (PubMed ID: 37032050)
1. Hollow microneedle microfluidic paper-based chip for biomolecules rapid sampling and detection in interstitial fluid.
Cheng J; Huang J; Xiang Q; Dong H
Anal Chim Acta; 2023 May; 1255():341101. PubMed ID: 37032050
[TBL] [Abstract][Full Text] [Related]
2. A Wearable Touch-Activated Device Integrated with Hollow Microneedles for Continuous Sampling and Sensing of Dermal Interstitial Fluid.
Abbasiasl T; Mirlou F; Mirzajani H; Bathaei MJ; Istif E; Shomalizadeh N; Cebecioğlu RE; Özkahraman EE; Yener UC; Beker L
Adv Mater; 2024 Jan; 36(2):e2304704. PubMed ID: 37709513
[TBL] [Abstract][Full Text] [Related]
3. Microfluidic chip connected to porous microneedle array for continuous ISF sampling.
Takeuchi K; Takama N; Sharma K; Paul O; Ruther P; Suga T; Kim B
Drug Deliv Transl Res; 2022 Feb; 12(2):435-443. PubMed ID: 34739717
[TBL] [Abstract][Full Text] [Related]
4. Soft microfiber-based hollow microneedle array for stretchable microfluidic biosensing patch with negative pressure-driven sampling.
Chinnamani MV; Hanif A; Kannan PK; Kaushal S; Sultan MJ; Lee NE
Biosens Bioelectron; 2023 Oct; 237():115468. PubMed ID: 37343311
[TBL] [Abstract][Full Text] [Related]
5. Rapid paper based colorimetric detection of glucose using a hollow microneedle device.
Nicholas D; Logan KA; Sheng Y; Gao J; Farrell S; Dixon D; Callan B; McHale AP; Callan JF
Int J Pharm; 2018 Aug; 547(1-2):244-249. PubMed ID: 29879505
[TBL] [Abstract][Full Text] [Related]
6. Porous Colorimetric Microneedles for Minimally Invasive Rapid Glucose Sampling and Sensing in Skin Interstitial Fluid.
Zeng Q; Xu M; Hu W; Cao W; Zhan Y; Zhang Y; Wang Q; Ma T
Biosensors (Basel); 2023 May; 13(5):. PubMed ID: 37232898
[TBL] [Abstract][Full Text] [Related]
7. An integrated wearable differential microneedle array for continuous glucose monitoring in interstitial fluids.
Yang Y; Sheng C; Dong F; Liu S
Biosens Bioelectron; 2024 Jul; 256():116280. PubMed ID: 38603840
[TBL] [Abstract][Full Text] [Related]
8. Three-Dimensional Paper-Based Microfluidic Analysis Device for Simultaneous Detection of Multiple Biomarkers with a Smartphone.
Baek SH; Park C; Jeon J; Park S
Biosensors (Basel); 2020 Nov; 10(11):. PubMed ID: 33233440
[TBL] [Abstract][Full Text] [Related]
9. Wearable hollow microneedle sensing patches for the transdermal electrochemical monitoring of glucose.
Parrilla M; Detamornrat U; Domínguez-Robles J; Donnelly RF; De Wael K
Talanta; 2022 Nov; 249():123695. PubMed ID: 35728453
[TBL] [Abstract][Full Text] [Related]
10. Enzyme embedded microfluidic paper-based analytic device (μPAD): a comprehensive review.
Nadar SS; Patil PD; Tiwari MS; Ahirrao DJ
Crit Rev Biotechnol; 2021 Nov; 41(7):1046-1080. PubMed ID: 33730940
[TBL] [Abstract][Full Text] [Related]
11. Salivary diagnostics on paper microfluidic devices and their use as wearable sensors for glucose monitoring.
de Castro LF; de Freitas SV; Duarte LC; de Souza JAC; Paixão TRLC; Coltro WKT
Anal Bioanal Chem; 2019 Jul; 411(19):4919-4928. PubMed ID: 30941478
[TBL] [Abstract][Full Text] [Related]
12. A Review on Microfluidic Paper-Based Analytical Devices for Glucose Detection.
Liu S; Su W; Ding X
Sensors (Basel); 2016 Dec; 16(12):. PubMed ID: 27941634
[TBL] [Abstract][Full Text] [Related]
13. Technical aspects and challenges of colorimetric detection with microfluidic paper-based analytical devices (μPADs) - A review.
Morbioli GG; Mazzu-Nascimento T; Stockton AM; Carrilho E
Anal Chim Acta; 2017 Jun; 970():1-22. PubMed ID: 28433054
[TBL] [Abstract][Full Text] [Related]
14. Microfluidic chip to interface porous microneedles for ISF collection.
Takeuchi K; Takama N; Kim B; Sharma K; Paul O; Ruther P
Biomed Microdevices; 2019 Mar; 21(1):28. PubMed ID: 30847695
[TBL] [Abstract][Full Text] [Related]
15. A Hydrogel Microneedle Patch for Point-of-Care Testing Based on Skin Interstitial Fluid.
He R; Niu Y; Li Z; Li A; Yang H; Xu F; Li F
Adv Healthc Mater; 2020 Feb; 9(4):e1901201. PubMed ID: 31957291
[TBL] [Abstract][Full Text] [Related]
16. Microneedle-Based Detection of Ketone Bodies along with Glucose and Lactate: Toward Real-Time Continuous Interstitial Fluid Monitoring of Diabetic Ketosis and Ketoacidosis.
Teymourian H; Moonla C; Tehrani F; Vargas E; Aghavali R; Barfidokht A; Tangkuaram T; Mercier PP; Dassau E; Wang J
Anal Chem; 2020 Jan; 92(2):2291-2300. PubMed ID: 31874029
[TBL] [Abstract][Full Text] [Related]
17. A Swellable Microneedle Patch to Rapidly Extract Skin Interstitial Fluid for Timely Metabolic Analysis.
Chang H; Zheng M; Yu X; Than A; Seeni RZ; Kang R; Tian J; Khanh DP; Liu L; Chen P; Xu C
Adv Mater; 2017 Oct; 29(37):. PubMed ID: 28714117
[TBL] [Abstract][Full Text] [Related]
18. Barrier-Free Microfluidic Paper Analytical Devices for Multiplex Colorimetric Detection of Analytes.
Chauhan A; Toley BJ
Anal Chem; 2021 Jun; 93(25):8954-8961. PubMed ID: 34126741
[TBL] [Abstract][Full Text] [Related]
19. Hollow Microneedles on a Paper Fabricated by Standard Photolithography for the Screening Test of Prediabetes.
Wu T; You X; Chen Z
Sensors (Basel); 2022 Jun; 22(11):. PubMed ID: 35684875
[TBL] [Abstract][Full Text] [Related]
20. Mechanisms of sampling interstitial fluid from skin using a microneedle patch.
Samant PP; Prausnitz MR
Proc Natl Acad Sci U S A; 2018 May; 115(18):4583-4588. PubMed ID: 29666252
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]