These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

253 related articles for article (PubMed ID: 37037992)

  • 21. Assessment of intracranial pressure with ultrasonographic retrobulbar optic nerve sheath diameter measurement.
    Liu D; Li Z; Zhang X; Zhao L; Jia J; Sun F; Wang Y; Ma D; Wei W
    BMC Neurol; 2017 Sep; 17(1):188. PubMed ID: 28962603
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Optic nerve sheath diameter measurement by ultrasound: Evaluation of a standardized protocol.
    Pansell J; Bell M; Rudberg P; Friman O; Cooray C
    J Neuroimaging; 2022 Jan; 32(1):104-110. PubMed ID: 34555223
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Correlation Between Invasive and Noninvasive Technique of Intracranial Pressure Measurement in Children With Traumatic Brain Injury: An Observational Study.
    Dhanda A; Singh GP; Bindra A
    J Neurosurg Anesthesiol; 2022 Apr; 34(2):221-226. PubMed ID: 33346598
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Noninvasive evaluation of intracranial pressure in patients with traumatic brain injury by transcranial Doppler ultrasound.
    Chang T; Yan X; Zhao C; Zhang Y; Wang B; Gao L
    Brain Behav; 2021 Dec; 11(12):e2396. PubMed ID: 34725957
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Ultrasonography Assessments of Optic Nerve Sheath Diameter as a Noninvasive and Dynamic Method of Detecting Changes in Intracranial Pressure.
    Wang LJ; Chen LM; Chen Y; Bao LY; Zheng NN; Wang YZ; Xing YQ
    JAMA Ophthalmol; 2018 Mar; 136(3):250-256. PubMed ID: 29392301
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Optic nerve sonographic examination to predict raised intracranial pressure in idiopathic intracranial hypertension: The cut-off points.
    Kishk NA; Ebraheim AM; Ashour AS; Badr NM; Eshra MA
    Neuroradiol J; 2018 Oct; 31(5):490-495. PubMed ID: 30024291
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Sonographic optic nerve sheath diameter as an estimate of intracranial pressure in adult trauma.
    Strumwasser A; Kwan RO; Yeung L; Miraflor E; Ereso A; Castro-Moure F; Patel A; Sadjadi J; Victorino GP
    J Surg Res; 2011 Oct; 170(2):265-71. PubMed ID: 21550065
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Correlation between ultrasonographic optic nerve sheath diameter and intracranial pressure].
    Li Z; Zhang XX; Yang HQ; Zhao LP; Jia JP; Sun F; Liu DC
    Zhonghua Yan Ke Za Zhi; 2018 Sep; 54(9):683-687. PubMed ID: 30220184
    [No Abstract]   [Full Text] [Related]  

  • 29. Optic nerve sheath diameter and pulsatility index for the diagnosis and follow-up in pediatric traumatic brain injury: a prospective observational cohort study.
    Saritas Nakip O; Pektezel MY; Terzi K; Kesici S; Bayrakci B
    Childs Nerv Syst; 2023 Sep; 39(9):2467-2477. PubMed ID: 37099137
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Perioperative Variation in Optic Nerve Sheath Diameter - A Prospective Observational Study of Traumatic Brain Injury Patients Undergoing Decompressive Craniectomy.
    Suresh V; Ushakumari PR; Aggarwal A; Kumar A; Kutty RK; Prabhakar RB; Peethambaran A
    Neurol India; 2022; 70(4):1460-1467. PubMed ID: 36076644
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Optic nerve sheath diameter measurement: a means of detecting raised ICP in adult traumatic and non-traumatic neurosurgical patients.
    Raffiz M; Abdullah JM
    Am J Emerg Med; 2017 Jan; 35(1):150-153. PubMed ID: 27852525
    [TBL] [Abstract][Full Text] [Related]  

  • 32. High-resolution transbulbar ultrasonography helping differentiate intracranial hypertension in bilateral optic disc oedema patients.
    Chen Q; Chen W; Wang M; Sun X; Sha Y; Li Z; Tian G
    Acta Ophthalmol; 2017 Sep; 95(6):e481-e485. PubMed ID: 28616896
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Comparison of accuracy of optic nerve ultrasound for the detection of intracranial hypertension in the setting of acutely fluctuating vs stable intracranial pressure: post-hoc analysis of data from a prospective, blinded single center study.
    Rajajee V; Fletcher JJ; Rochlen LR; Jacobs TL
    Crit Care; 2012 May; 16(3):R79. PubMed ID: 22578001
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Estimation of intracranial pressure by ultrasound of the optic nerve sheath in an animal model of intracranial hypertension.
    Jeng BCP; de Andrade AF; Brasil S; Bor-Seng-Shu E; Belon AR; Robertis M; de-Lima-Oliveira M; Rubiano AM; Godoy DA; Teixeira MJ; Paiva WS
    J Clin Neurosci; 2021 Apr; 86():174-179. PubMed ID: 33775322
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Optic nerve ultrasound for the detection of raised intracranial pressure.
    Rajajee V; Vanaman M; Fletcher JJ; Jacobs TL
    Neurocrit Care; 2011 Dec; 15(3):506-15. PubMed ID: 21769456
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Ocular ultrasound to detect intracranial hypertension in trauma patients.
    Cammarata G; Ristagno G; Cammarata A; Mannanici G; Denaro C; Gullo A
    J Trauma; 2011 Sep; 71(3):779-81. PubMed ID: 21909008
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Effect of different positive end expiratory pressure levels on optic nerve sheath diameter in patients with or without midline shift who are undergoing supratentorial craniotomy.
    Fenerci A; Akcil EF; Tunali Y; Dilmen OK
    Acta Neurochir (Wien); 2024 Apr; 166(1):177. PubMed ID: 38622368
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Ultrasound of the Optic Nerve Does Not Appear to Be a Consistently Reliable or Generalizable Method to Monitor Changes in Intracranial Pressure.
    Butts C; Wilson J; Lasseigne L; Oral E; Kaban N
    J Intensive Care Med; 2022 May; 37(5):663-670. PubMed ID: 34075826
    [TBL] [Abstract][Full Text] [Related]  

  • 39. The Effect of Different Optic Nerve Sheath Diameter Measurements Using Ultrasound to Assess Intracranial Pressure in Patients With Acute Brain Injury.
    Tian J; Wu GB; Liu XB; Wang ZY; Guo JY
    J Neuroophthalmol; 2024 Jun; 44(2):201-205. PubMed ID: 37440369
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Dimensions of Arachnoid Bulk Ratio: A Superior Optic Nerve Sheath Index for Intracranial Pressure.
    Berhanu D; Carneiro I; Antunes AP; Abegão Pinto L; Fragata I; Tavares Ferreira J; Lucas Neto L
    Radiology; 2024 Jul; 312(1):e240114. PubMed ID: 38980182
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 13.