These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
299 related articles for article (PubMed ID: 37041561)
1. Effect of EIT-guided PEEP titration on prognosis of patients with moderate to severe ARDS: study protocol for a multicenter randomized controlled trial. Yuan X; Zhang R; Wang Y; Chen D; Chao Y; Xu J; Guo L; Liu A; Xie J; Pan C; Yang Y; Qiu H; Liu L Trials; 2023 Apr; 24(1):266. PubMed ID: 37041561 [TBL] [Abstract][Full Text] [Related]
2. Early individualized positive end-expiratory pressure guided by electrical impedance tomography in acute respiratory distress syndrome: a randomized controlled clinical trial. He H; Chi Y; Yang Y; Yuan S; Long Y; Zhao P; Frerichs I; Fu F; Möller K; Zhao Z Crit Care; 2021 Jun; 25(1):230. PubMed ID: 34193224 [TBL] [Abstract][Full Text] [Related]
3. Multicentre, parallel, open-label, two-arm, randomised controlled trial on the prognosis of electrical impedance tomography-guided versus low PEEP/FiO2 table-guided PEEP setting: a trial protocol. Wong H; Chi Y; Zhang R; Yin C; Jia J; Wang B; Liu Y; Shang Y; Wang R; Long Y; Zhao Z; He H BMJ Open; 2024 Feb; 14(2):e080828. PubMed ID: 38307528 [TBL] [Abstract][Full Text] [Related]
4. Electrical impedance tomography for titration of positive end-expiratory pressure in acute respiratory distress syndrome patients with chronic obstructive pulmonary disease. Liu X; Liu X; Meng J; Liu D; Huang Y; Sang L; Xu Y; Xu Z; He W; Chen S; Zhang R; Liu X; Li Y Crit Care; 2022 Nov; 26(1):339. PubMed ID: 36333809 [TBL] [Abstract][Full Text] [Related]
5. Electric impedance tomography-guided PEEP titration reduces mechanical power in ARDS: a randomized crossover pilot trial. Jimenez JV; Munroe E; Weirauch AJ; Fiorino K; Culter CA; Nelson K; Labaki WW; Choi PJ; Co I; Standiford TJ; Prescott HC; Hyzy RC Crit Care; 2023 Jan; 27(1):21. PubMed ID: 36650593 [TBL] [Abstract][Full Text] [Related]
6. Individualized positive end-expiratory pressure guided by end-expiratory lung volume in early acute respiratory distress syndrome: study protocol for the multicenter, randomized IPERPEEP trial. Grieco DL; Maggiore SM; Bellani G; Spadaro S; Spinelli E; Tonetti T; Menga LS; Pozzi M; Battaglini D; Di Mussi R; Bruni A; De Gaetano A; Iovino CG; Brioni M; Mojoli F; Foti G; Volta CA; Pelosi P; Navalesi P; Grasso S; Ranieri VM; Antonelli M; Trials; 2022 Jan; 23(1):63. PubMed ID: 35057852 [TBL] [Abstract][Full Text] [Related]
7. Rationale, study design, and analysis plan of the Alveolar Recruitment for ARDS Trial (ART): study protocol for a randomized controlled trial. ART Investigators Trials; 2012 Aug; 13():153. PubMed ID: 22929542 [TBL] [Abstract][Full Text] [Related]
8. Positive end-expiratory pressure titration with electrical impedance tomography and pressure-volume curve in severe acute respiratory distress syndrome. Zhao Z; Chang MY; Chang MY; Gow CH; Zhang JH; Hsu YL; Frerichs I; Chang HT; Möller K Ann Intensive Care; 2019 Jan; 9(1):7. PubMed ID: 30656479 [TBL] [Abstract][Full Text] [Related]
9. Effect of Titrating Positive End-Expiratory Pressure (PEEP) With an Esophageal Pressure-Guided Strategy vs an Empirical High PEEP-Fio2 Strategy on Death and Days Free From Mechanical Ventilation Among Patients With Acute Respiratory Distress Syndrome: A Randomized Clinical Trial. Beitler JR; Sarge T; Banner-Goodspeed VM; Gong MN; Cook D; Novack V; Loring SH; Talmor D; JAMA; 2019 Mar; 321(9):846-857. PubMed ID: 30776290 [TBL] [Abstract][Full Text] [Related]
10. Model-based PEEP titration versus standard practice in mechanical ventilation: a randomised controlled trial. Kim KT; Morton S; Howe S; Chiew YS; Knopp JL; Docherty P; Pretty C; Desaive T; Benyo B; Szlavecz A; Moeller K; Shaw GM; Chase JG Trials; 2020 Feb; 21(1):130. PubMed ID: 32007099 [TBL] [Abstract][Full Text] [Related]
11. Assessment of electrical impedance tomography to set optimal positive end-expiratory pressure for veno-venous ECMO-treated severe ARDS patients. Puel F; Crognier L; Soulé C; Vardon-Bounes F; Ruiz S; Seguin T; Fourcade O; Minville V; Conil JM; Georges B J Crit Care; 2020 Dec; 60():38-44. PubMed ID: 32736198 [TBL] [Abstract][Full Text] [Related]
12. Permissive Hypercapnia, Alveolar Recruitment and Low Airway Pressure (PHARLAP): a protocol for a phase 2 trial in patients with acute respiratory distress syndrome. Hodgson C; Cooper DJ; Arabi Y; Bennett V; Bersten A; Brickell K; Davies A; Fahey C; Fraser J; McGuinness S; Murray L; Parke R; Tuxen D; Vallance S; Young M; Nichol AD; Crit Care Resusc; 2018 Jun; 20(2):139-149. PubMed ID: 29852853 [TBL] [Abstract][Full Text] [Related]
13. Personalized mechanical ventilation guided by ultrasound in patients with acute respiratory distress syndrome (PEGASUS): study protocol for an international randomized clinical trial. Sinnige JS; Smit MR; Ghose A; de Grooth HJ; Itenov TS; Ischaki E; Laffey J; Paulus F; Póvoa P; Pierrakos C; Pisani L; Roca O; Schultz MJ; Szuldrzynski K; Tuinman PR; Zimatore C; Bos LDJ; Trials; 2024 May; 25(1):308. PubMed ID: 38715118 [TBL] [Abstract][Full Text] [Related]
14. Electrical impedance tomography-guided positive end-expiratory pressure titration in ARDS: a systematic review and meta-analysis. Songsangvorn N; Xu Y; Lu C; Rotstein O; Brochard L; Slutsky AS; Burns KEA; Zhang H Intensive Care Med; 2024 May; 50(5):617-631. PubMed ID: 38512400 [TBL] [Abstract][Full Text] [Related]
15. Rationale, study design and analysis plan of the lung imaging morphology for ventilator settings in acute respiratory distress syndrome study (LIVE study): Study protocol for a randomised controlled trial. Jabaudon M; Godet T; Futier E; Bazin JÉ; Sapin V; Roszyk L; Pereira B; Constantin JM; Anaesth Crit Care Pain Med; 2017 Oct; 36(5):301-306. PubMed ID: 28323236 [TBL] [Abstract][Full Text] [Related]
16. Positive end-expiratory pressure titration with electrical impedance tomography and pressure-volume curve: a randomized trial in moderate to severe ARDS. Hsu HJ; Chang HT; Zhao Z; Wang PH; Zhang JH; Chen YS; Frerichs I; Möller K; Fu F; Hsu HS; Chuang SP; Hsia HY; Yen DH Physiol Meas; 2021 Feb; 42(1):014002. PubMed ID: 33361553 [TBL] [Abstract][Full Text] [Related]
17. Effect of Lung Recruitment and Titrated Positive End-Expiratory Pressure (PEEP) vs Low PEEP on Mortality in Patients With Acute Respiratory Distress Syndrome: A Randomized Clinical Trial. ; Cavalcanti AB; Suzumura ÉA; Laranjeira LN; Paisani DM; Damiani LP; Guimarães HP; Romano ER; Regenga MM; Taniguchi LNT; Teixeira C; Pinheiro de Oliveira R; Machado FR; Diaz-Quijano FA; Filho MSA; Maia IS; Caser EB; Filho WO; Borges MC; Martins PA; Matsui M; Ospina-Tascón GA; Giancursi TS; Giraldo-Ramirez ND; Vieira SRR; Assef MDGPL; Hasan MS; Szczeklik W; Rios F; Amato MBP; Berwanger O; Ribeiro de Carvalho CR JAMA; 2017 Oct; 318(14):1335-1345. PubMed ID: 28973363 [TBL] [Abstract][Full Text] [Related]
18. Compliance-guided versus FiO Pintado MC; de Pablo R; Trascasa M; Milicua JM; Sánchez-García M Med Intensiva; 2017; 41(5):277-284. PubMed ID: 27776936 [TBL] [Abstract][Full Text] [Related]
19. PEEP titration by EIT strategies for patients with ARDS: A systematic review and meta-analysis. Yu M; Deng Y; Cha J; Jiang L; Wang M; Qiao S; Wang C Med Intensiva (Engl Ed); 2023 Jul; 47(7):383-390. PubMed ID: 36243630 [TBL] [Abstract][Full Text] [Related]
20. Electrical impedance tomography: A compass for the safe route to optimal PEEP. Sella N; Pettenuzzo T; Zarantonello F; Andreatta G; De Cassai A; Schiavolin C; Simoni C; Pasin L; Boscolo A; Navalesi P Respir Med; 2021 Oct; 187():106555. PubMed ID: 34352563 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]