These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

129 related articles for article (PubMed ID: 37051689)

  • 1. Automatic non-invasive blood pressure measurement in left ventricular assist device patients with a photoplethysmography assisted device.
    Nagy P; Sax B; Kozák A; Merkely B; Osztheimer I; Jobbágy Á
    Int J Artif Organs; 2023 May; 46(5):274-279. PubMed ID: 37051689
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Validity and reliability of a novel slow cuff-deflation system for noninvasive blood pressure monitoring in patients with continuous-flow left ventricular assist device.
    Lanier GM; Orlanes K; Hayashi Y; Murphy J; Flannery M; Te-Frey R; Uriel N; Yuzefpolskaya M; Mancini DM; Naka Y; Takayama H; Jorde UP; Demmer RT; Colombo PC
    Circ Heart Fail; 2013 Sep; 6(5):1005-12. PubMed ID: 23811966
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Noninvasive blood pressure measurement in patients with continuous-flow left ventricular assist devices.
    Tanaka A; Kiriyama Y; Kubo N; Sakaguchi R; Uchiyama A; Fujino Y
    J Artif Organs; 2023 Jun; 26(2):160-164. PubMed ID: 35907151
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Pulse Oximeter Derived Blood Pressure Measurement in Patients With a Continuous Flow Left Ventricular Assist Device.
    Hellman Y; Malik AS; Lane KA; Shen C; Wang IW; Wozniak TC; Hashmi ZA; Munson SD; Pickrell J; Caccamo MA; Gradus-Pizlo I; Hadi A
    Artif Organs; 2017 May; 41(5):424-430. PubMed ID: 27782305
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Outcomes based on blood pressure in patients on continuous flow left ventricular assist device support: An Interagency Registry for Mechanically Assisted Circulatory Support analysis.
    Cowger JA; Shah P; Pagani FD; Grafton G; Stulak J; Chamogeorgakis T; Lanfear D; Nemeh H; Pinney S
    J Heart Lung Transplant; 2020 May; 39(5):441-453. PubMed ID: 31831209
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy of Doppler blood pressure measurement in continuous-flow left ventricular assist device patients.
    Li S; Beckman JA; Welch NG; Bjelkengren J; Masri SC; Minami E; Stempien-Otero A; Levy WC; O'Brien KD; Lin S; Farris SD; Cheng RK; Wood G; Koomalsingh K; Kirkpatrick J; McCabe J; Leary PJ; Chassagne F; Chivukula VK; Aliseda A; Mahr C
    ESC Heart Fail; 2019 Aug; 6(4):793-798. PubMed ID: 31099483
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Validity and success rate of noninvasive mean arterial blood pressure measurements in cf-LVAD patients: A technical review.
    Lankheet S; Pieterse MM; Rijnhout R; Tuerlings E; Oppelaar AC; van Laake LW; Ramjankhan FZ; Westerhof BE; Oerlemans MIFJ
    Artif Organs; 2022 Dec; 46(12):2361-2370. PubMed ID: 35920238
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Radial Artery Tonometry to Monitor Blood Pressure and Hemodynamics in Ambulatory Left Ventricular Assist Device Patients in Comparison With Doppler Ultrasound and Transthoracic Echocardiography: A Pilot Study.
    Zayat R; Drosos V; Schnoering H; Lee JY; Bleilevens C; Musetti G; Jansen-Park SH; Kang H; Menon AK; Schmitz-Rode T; Autschbach R; Hatam N; Moza A
    Artif Organs; 2019 Mar; 43(3):242-253. PubMed ID: 30040134
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Cavoaortic shunt improves hemodynamics with preserved oxygen delivery in experimental right ventricular failure during left ventricular assist device therapy.
    Vikholm P; Schiller P; Johansson J; Hellgren L
    J Thorac Cardiovasc Surg; 2014 Feb; 147(2):625-31. PubMed ID: 23477692
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Prediction of hemodynamics under left ventricular assist device.
    Kakino T; Saku K; Sakamoto T; Sakamoto K; Akashi T; Ikeda M; Ide T; Kishi T; Tsutsui H; Sunagawa K
    Am J Physiol Heart Circ Physiol; 2017 Jan; 312(1):H80-H88. PubMed ID: 27793856
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Does postoperative blood pressure influence development of aortic regurgitation following continuous-flow left ventricular assist device implantation?†.
    Patil NP; Mohite PN; Sabashnikov A; Dhar D; Weymann A; Zeriouh M; Koch A; Garcia-Saez D; Zych B; Hards R; Hedger M; De Robertis F; Moza A; Bahrami T; Amrani M; Rahman-Haley S; Popov AF; Banner N; Simon AR
    Eur J Cardiothorac Surg; 2016 Mar; 49(3):788-94. PubMed ID: 26108216
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Alternative approach for right ventricular failure after left ventricular assist device placement in animal model.
    Saito T; Toda K; Takewa Y; Tsukiya T; Mizuno T; Taenaka Y; Tatsumi E
    Eur J Cardiothorac Surg; 2015 Jul; 48(1):98-103. PubMed ID: 25293402
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Early Right Ventricular Assist Device Use in Patients Undergoing Continuous-Flow Left Ventricular Assist Device Implantation: Incidence and Risk Factors From the Interagency Registry for Mechanically Assisted Circulatory Support.
    Kiernan MS; Grandin EW; Brinkley M; Kapur NK; Pham DT; Ruthazer R; Rame JE; Atluri P; Birati EY; Oliveira GH; Pagani FD; Kirklin JK; Naftel D; Kormos RL; Teuteberg JJ; DeNofrio D
    Circ Heart Fail; 2017 Oct; 10(10):. PubMed ID: 29021348
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Mean Arterial Pressure to Central Venous Pressure Ratio: A Novel Marker for Right Ventricular Failure After Left Ventricular Assist Device Placement.
    Mohamedali B; Doukky R; Karavalos K; Avery E; Bhat G
    J Card Fail; 2017 Jun; 23(6):446-452. PubMed ID: 28365215
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Non-invasive assessment of arterial pulsatility in patients with continuous-flow left ventricular assist devices.
    Cross TJ; Sajgalik P; Fabian V; Matera L; Kushwaha SS; Maltais S; Stulak JM; Schirger JA; Johnson BD
    Int J Artif Organs; 2020 Feb; 43(2):99-108. PubMed ID: 31411101
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Hypertension: an unstudied potential risk factor for adverse outcomes during continuous flow ventricular assist device support.
    Wasson LT; Yuzefpolskaya M; Wakabayashi M; Takayama H; Naka Y; Uriel N; Jorde UP; Demmer RT; Colombo PC
    Heart Fail Rev; 2015 May; 20(3):317-22. PubMed ID: 25283767
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Risk Assessment and Comparative Effectiveness of Left Ventricular Assist Device and Medical Management in Ambulatory Heart Failure Patients: The ROADMAP Study 2-Year Results.
    Starling RC; Estep JD; Horstmanshof DA; Milano CA; Stehlik J; Shah KB; Bruckner BA; Lee S; Long JW; Selzman CH; Kasirajan V; Haas DC; Boyle AJ; Chuang J; Farrar DJ; Rogers JG;
    JACC Heart Fail; 2017 Jul; 5(7):518-527. PubMed ID: 28396040
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Noninvasive measurement of arterial blood pressure in patients with continuous-flow left ventricular assist devices: a systematic review.
    Alvarez PA; Ponnapureddy R; Voruganti D; Duque ER; Briasoulis A
    Heart Fail Rev; 2021 Jan; 26(1):47-55. PubMed ID: 32696152
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Outcomes after implantation of partial-support left ventricular assist devices in inotropic-dependent patients: Do we still need full-support assist devices?
    Sabashnikov A; Popov AF; Bowles CT; Mohite PN; Weymann A; Hards R; Hedger M; Wittwer T; Wippermann J; Wahlers T; Schoendube FA; Simon AR
    J Thorac Cardiovasc Surg; 2014 Sep; 148(3):1115-21; discussion 1021-2. PubMed ID: 25129605
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Noninvasive assessment of blood pressure in rotary blood pump recipients using a novel ultrasonic Doppler method.
    Granegger M; Thamsen B; Moscato F; Schlöglhofer T; Gross C; Schneider S; Röhrich M; Kertzscher U; Zimpfer D; Affeld K; Schima H
    Int J Artif Organs; 2019 May; 42(5):226-232. PubMed ID: 30854909
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.