124 related articles for article (PubMed ID: 37052059)
1. Agreement between cardiac output measurements by pulse wave analysis using the Pressure Recording Analytical Method and transthoracic echocardiography in patients with veno-venous extracorporeal membrane oxygenation therapy: An observational method comparison.
Greiwe G; Flick M; Hapfelmeier A; Winkler MS; Nitzschke R; Frings D; Saugel B
Eur J Anaesthesiol; 2023 Jun; 40(6):436-441. PubMed ID: 37052059
[TBL] [Abstract][Full Text] [Related]
2. Pulse Wave Analysis Using the Pressure Recording Analytical Method to Measure Cardiac Output in Pediatric Cardiac Surgery Patients: A Method Comparison Study Using Transesophageal Doppler Echocardiography as Reference Method.
Greiwe G; Balfanz V; Hapfelmeier A; Zajonz TS; Müller M; Saugel B; Schulte-Uentrop L
Anesth Analg; 2022 Jul; 135(1):71-78. PubMed ID: 35452017
[TBL] [Abstract][Full Text] [Related]
3. Cardiac output estimation by pulse wave analysis using the pressure recording analytical method and intermittent pulmonary artery thermodilution: A method comparison study after off-pump coronary artery bypass surgery.
Greiwe G; Luehsen K; Hapfelmeier A; Rogge D; Kubik M; Schulte-Uentrop L; Saugel B
Eur J Anaesthesiol; 2020 Oct; 37(10):920-925. PubMed ID: 32398582
[TBL] [Abstract][Full Text] [Related]
4. Comparision of cardiac output measured by transthoracic echocardiography with continuous cardiac output measured by pressure recording analytical method.
Madhuri MR; Singh NG; Nagaraja PS; Pranathi E; Prabhu Shankar CG; Satish N; Prabhakar V; Gupta A
Ann Card Anaesth; 2023; 26(2):155-159. PubMed ID: 37706379
[TBL] [Abstract][Full Text] [Related]
5. Comparison of estimation of cardiac output using an uncalibrated pulse contour method and echocardiography during veno-venous extracorporeal membrane oxygenation.
Bond O; Pozzebon S; Franchi F; Zama Cavicchi F; Creteur J; Vincent JL; Taccone FS; Scolletta S
Perfusion; 2020 Jul; 35(5):397-401. PubMed ID: 31709902
[TBL] [Abstract][Full Text] [Related]
6. Continuous cardiac output monitoring with an uncalibrated pulse contour method in patients supported with mechanical pulsatile assist device.
Scolletta S; Miraldi F; Romano SM; Muzzi L
Interact Cardiovasc Thorac Surg; 2011 Jul; 13(1):52-6. PubMed ID: 21454314
[TBL] [Abstract][Full Text] [Related]
7. FloTrac/Vigileo(TM) (third generation) and MostCare(®)/PRAM versus echocardiography for cardiac output estimation in vascular surgery.
Romagnoli S; Ricci Z; Romano SM; Dimizio F; Bonicolini E; Quattrone D; De Gaudio R
J Cardiothorac Vasc Anesth; 2013 Dec; 27(6):1114-21. PubMed ID: 24055563
[TBL] [Abstract][Full Text] [Related]
8. Validation of maternal cardiac output assessed by transthoracic echocardiography against pulmonary artery catheterization in severely ill pregnant women: prospective comparative study and systematic review.
Cornette J; Laker S; Jeffery B; Lombaard H; Alberts A; Rizopoulos D; Roos-Hesselink JW; Pattinson RC
Ultrasound Obstet Gynecol; 2017 Jan; 49(1):25-31. PubMed ID: 27404397
[TBL] [Abstract][Full Text] [Related]
9. Transthoracic echocardiography: an accurate and precise method for estimating cardiac output in the critically ill patient.
Mercado P; Maizel J; Beyls C; Titeca-Beauport D; Joris M; Kontar L; Riviere A; Bonef O; Soupison T; Tribouilloy C; de Cagny B; Slama M
Crit Care; 2017 Jun; 21(1):136. PubMed ID: 28595621
[TBL] [Abstract][Full Text] [Related]
10. Thermodilution vs pressure recording analytical method in hemodynamic stabilized patients.
Donati A; Carsetti A; Tondi S; Scorcella C; Domizi R; Damiani E; Gabbanelli V; Münch C; Adrario E; Pelaia P; Cecconi M
J Crit Care; 2014 Apr; 29(2):260-4. PubMed ID: 24332994
[TBL] [Abstract][Full Text] [Related]
11. Assessment of cardiac output from systemic arterial pressure in humans.
Romano SM; Pistolesi M
Crit Care Med; 2002 Aug; 30(8):1834-41. PubMed ID: 12163802
[TBL] [Abstract][Full Text] [Related]
12. Pressure recording analytical method for measuring cardiac output in critically ill children: a validation study.
Saxena R; Durward A; Puppala NK; Murdoch IA; Tibby SM
Br J Anaesth; 2013 Mar; 110(3):425-31. PubMed ID: 23183320
[TBL] [Abstract][Full Text] [Related]
13. Comparison between radial artery tonometry pulse analyzer and pulsed-Doppler echocardiography derived hemodynamic parameters in cardiac surgery patients: a pilot study.
Zayat R; Goetzenich A; Lee JY; Kang H; Jansen-Park SH; Schmitz-Rode T; Musetti G; Schnoering H; Autschbach R; Hatam N; Aljalloud A
PeerJ; 2017; 5():e4132. PubMed ID: 29230366
[TBL] [Abstract][Full Text] [Related]
14. Agreement between cardiac output measurements by pulse wave analysis using the Pressure Recording Analytical Method and transthoracic echocardiography in patients with veno-venous extracorporeal membrane oxygenation therapy: An observational method comparison: Erratum.
Eur J Anaesthesiol; 2023 Nov; 40(11):878. PubMed ID: 37789755
[No Abstract] [Full Text] [Related]
15. Cardiac output by arterial pulse contour: reliability under hemodynamic derangements.
Romagnoli S; Romano SM; Bevilacqua S; Ciappi F; Lazzeri C; Peris A; Dini D; Gelsomino S
Interact Cardiovasc Thorac Surg; 2009 Jun; 8(6):642-6. PubMed ID: 19299422
[TBL] [Abstract][Full Text] [Related]
16. Comparison of noninvasive continuous arterial waveform analysis (Nexfin) with transthoracic Doppler echocardiography for monitoring of cardiac output.
van der Spoel AG; Voogel AJ; Folkers A; Boer C; Bouwman RA
J Clin Anesth; 2012 Jun; 24(4):304-9. PubMed ID: 22608585
[TBL] [Abstract][Full Text] [Related]
17. Cardiac output monitoring by pressure recording analytical method in cardiac surgery.
Giomarelli P; Biagioli B; Scolletta S
Eur J Cardiothorac Surg; 2004 Sep; 26(3):515-20. PubMed ID: 15302045
[TBL] [Abstract][Full Text] [Related]
18. Cardiac output estimation by multi-beat analysis of the radial arterial blood pressure waveform versus intermittent pulmonary artery thermodilution: a method comparison study in patients treated in the intensive care unit after off-pump coronary artery bypass surgery.
Greiwe G; Peters V; Hapfelmeier A; Romagnoli S; Kubik M; Saugel B
J Clin Monit Comput; 2020 Aug; 34(4):643-648. PubMed ID: 31456071
[TBL] [Abstract][Full Text] [Related]
19. A preliminary study evaluating cardiac output measurement using Pressure Recording Analytical Method (PRAM) in anaesthetized dogs.
Briganti A; Evangelista F; Centonze P; Rizzo A; Bentivegna F; Crovace A; Staffieri F
BMC Vet Res; 2018 Mar; 14(1):72. PubMed ID: 29510691
[TBL] [Abstract][Full Text] [Related]
20. Echo is a good, not perfect, measure of cardiac output in critically ill surgical patients.
Olivieri PP; Patel R; Kolb S; Fatima S; Galvagno SM; Haase DJ; Ramani GV; Ludmir J; Alkhatib H; Herr D; Bruno DA; Scalea TM; Murthi SB
J Trauma Acute Care Surg; 2019 Aug; 87(2):379-385. PubMed ID: 31349350
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]