BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

129 related articles for article (PubMed ID: 37062795)

  • 21. Reducing the levels of formaldehyde exposure in gross anatomy laboratories.
    Coleman R
    Anat Rec; 1995 Dec; 243(4):531-3. PubMed ID: 8597301
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Personal formaldehyde exposure level in the gross anatomy dissecting room at College of Medicine King Saud University Riyadh.
    Vohra MS
    Int J Occup Med Environ Health; 2011 Mar; 24(1):108-13. PubMed ID: 21468908
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Comparison between active (pumped) and passive (diffusive) sampling methods for formaldehyde in pathology and histology laboratories.
    Lee EG; Magrm R; Kusti M; Kashon ML; Guffey S; Costas MM; Boykin CJ; Harper M
    J Occup Environ Hyg; 2017 Jan; 14(1):31-39. PubMed ID: 27715715
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Local exhaust ventilation systems for the gross anatomy laboratory.
    Zdilla MJ
    Morphologie; 2021 Sep; 105(350):237-246. PubMed ID: 33279395
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Attempt to reduce the formaldehyde concentration by blowing cooled fresh air down in to the breathing zone of medical students from an admission port on the ceiling during gross anatomy class].
    Takayanagi M; Sakai M; Ishikawa Y; Murakami K; Kimura A; Kakuta S; Sato F
    Kaibogaku Zasshi; 2008 Sep; 83(3):87-93. PubMed ID: 18807948
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [Exposure to formaldehyde during an anatomy dissecting course].
    Kunugita N; Nakashima T; Kikuta A; Kawamoto T; Arashidani K
    J UOEH; 2004 Sep; 26(3):337-48. PubMed ID: 15471282
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Toxicity of formaldehyde exposure and the details of its control measures].
    Uchiyama I
    Kaibogaku Zasshi; 2010 Mar; 85(1):29-34. PubMed ID: 20384188
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Controlling formaldehyde exposures in an academic gross anatomy laboratory.
    Klein RC; King C; Castagna P
    J Occup Environ Hyg; 2014; 11(3):127-32. PubMed ID: 24521062
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Characterization of formaldehyde exposure resulting from the use of four professional hair straightening products.
    Pierce JS; Abelmann A; Spicer LJ; Adams RE; Glynn ME; Neier K; Finley BL; Gaffney SH
    J Occup Environ Hyg; 2011 Nov; 8(11):686-99. PubMed ID: 22035353
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Occupational exposure to formaldehyde in an institute of morphology in Brazil: a comparison of area and personal sampling.
    Ochs Sde M; Grotz Lde O; Factorine LS; Rodrigues MR; Pereira Netto AD
    Environ Sci Pollut Res Int; 2011 Aug; 19(7):2813-9. PubMed ID: 22322292
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Effect of large-scale repair work on indoor formaldehyde levels upon and subjective symptoms in, medical students during gross anatomy dissection course].
    Mori M; Hoshiko M; Hara K; Ishitake T; Saga T; Yamaki K
    Nihon Eiseigaku Zasshi; 2012; 67(4):501-7. PubMed ID: 23095362
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Medical students' exposure to formaldehyde in a gross anatomy dissection laboratory.
    Chia SE; Ong CN; Foo SC; Lee HP
    J Am Coll Health; 1992 Nov; 41(3):115-9. PubMed ID: 1430673
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Successful reduction of morticians' exposure to formaldehyde during embalming procedures.
    Hiipakka DW; Dyrdahl KS; Garcia Cardenas M
    AIHAJ; 2001; 62(6):689-96. PubMed ID: 11767933
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Field precision of formaldehyde sampling and analysis using NIOSH method 3500.
    Akbar-Khanzadeh F; Park CK
    Am Ind Hyg Assoc J; 1997 Sep; 58(9):657-60. PubMed ID: 9291564
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Designing, construction, assessment, and efficiency of local exhaust ventilation in controlling crystalline silica dust and particles, and formaldehyde in a foundry industry plant.
    Morteza MM; Hossein K; Amirhossein M; Naser H; Gholamhossein H; Hossein F
    Arh Hig Rada Toksikol; 2013; 64(1):123-31. PubMed ID: 23585164
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Determination of formaldehyde levels in 100 furniture workshops in Ankara.
    Vaizoğlu SA; Aycan S; Akin L; Koçdor P; Pamukçu G; Muhsinoğlu O; Ozer F; Evci ED; Güler C
    Tohoku J Exp Med; 2005 Oct; 207(2):157-63. PubMed ID: 16141685
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A strategy for the reduction of formaldehyde concentration in a hospital pathology laboratory.
    Ogawa M; Kabe I; Terauchi Y; Tanaka S
    J Occup Health; 2019 Jan; 61(1):135-142. PubMed ID: 30698343
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Excruciating effect of formaldehyde exposure to students in gross anatomy dissection laboratory.
    Onyije FM; Avwioro OG
    Int J Occup Environ Med; 2012 Apr; 3(2):92-5. PubMed ID: 23022856
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Video exposure assessments demonstrate excessive laboratory formaldehyde exposures.
    Ryan TJ; Burroughs GE; Taylor K; Kovein RJ
    Appl Occup Environ Hyg; 2003 Jun; 18(6):450-7. PubMed ID: 12746068
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Potential health hazards for students exposed to formaldehyde in the gross anatomy laboratory.
    Raja DS; Sultana B
    J Environ Health; 2012; 74(6):36-40. PubMed ID: 22329207
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.