These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
135 related articles for article (PubMed ID: 37068840)
1. New Contrast Media for K-Edge Imaging With Photon-Counting Detector CT. Jost G; McDermott M; Gutjahr R; Nowak T; Schmidt B; Pietsch H Invest Radiol; 2023 Jul; 58(7):515-522. PubMed ID: 37068840 [TBL] [Abstract][Full Text] [Related]
2. Feasibility of multi-contrast imaging on dual-source photon counting detector (PCD) CT: An initial phantom study. Tao S; Rajendran K; McCollough CH; Leng S Med Phys; 2019 Sep; 46(9):4105-4115. PubMed ID: 31215659 [TBL] [Abstract][Full Text] [Related]
3. Simultaneous Dual-Contrast Imaging of Small Bowel With Iodine and Bismuth Using Photon-Counting-Detector Computed Tomography: A Feasibility Animal Study. Ren L; Rajendran K; Fletcher JG; McCollough CH; Yu L Invest Radiol; 2020 Oct; 55(10):688-694. PubMed ID: 32530868 [TBL] [Abstract][Full Text] [Related]
4. Photon-Counting Computed Tomography for Vascular Imaging of the Head and Neck: First In Vivo Human Results. Symons R; Reich DS; Bagheri M; Cork TE; Krauss B; Ulzheimer S; Kappler S; Bluemke DA; Pourmorteza A Invest Radiol; 2018 Mar; 53(3):135-142. PubMed ID: 28926370 [TBL] [Abstract][Full Text] [Related]
5. Photon-Counting Multienergy Computed Tomography With Spectrally Optimized Contrast Media for Plaque Removal and Stenosis Assessment. Sartoretti T; Eberhard M; Nowak T; Gutjahr R; Jost G; Pietsch H; Schmidt B; Flohr T; Alkadhi H; Euler A Invest Radiol; 2021 Sep; 56(9):563-570. PubMed ID: 33660630 [TBL] [Abstract][Full Text] [Related]
6. An introduction to photon-counting detector CT (PCD CT) for radiologists. Nakamura Y; Higaki T; Kondo S; Kawashita I; Takahashi I; Awai K Jpn J Radiol; 2023 Mar; 41(3):266-282. PubMed ID: 36255601 [TBL] [Abstract][Full Text] [Related]
7. Human Imaging With Photon Counting-Based Computed Tomography at Clinical Dose Levels: Contrast-to-Noise Ratio and Cadaver Studies. Gutjahr R; Halaweish AF; Yu Z; Leng S; Yu L; Li Z; Jorgensen SM; Ritman EL; Kappler S; McCollough CH Invest Radiol; 2016 Jul; 51(7):421-9. PubMed ID: 26818529 [TBL] [Abstract][Full Text] [Related]
8. Photon-counting CT with tungsten as contrast medium: Experimental evidence of vessel lumen and plaque visualization. Sartoretti T; Eberhard M; Rüschoff JH; Pietsch H; Jost G; Nowak T; Schmidt B; Flohr T; Euler A; Alkadhi H Atherosclerosis; 2020 Oct; 310():11-16. PubMed ID: 32861961 [TBL] [Abstract][Full Text] [Related]
9. Material decomposition with a prototype photon-counting detector CT system: expanding a stoichiometric dual-energy CT method via energy bin optimization and K-edge imaging. Richtsmeier D; Rodesch PA; Iniewski K; Bazalova-Carter M Phys Med Biol; 2024 Feb; 69(5):. PubMed ID: 38306974 [No Abstract] [Full Text] [Related]
11. Dual-contrast agent photon-counting computed tomography of the heart: initial experience. Symons R; Cork TE; Lakshmanan MN; Evers R; Davies-Venn C; Rice KA; Thomas ML; Liu CY; Kappler S; Ulzheimer S; Sandfort V; Bluemke DA; Pourmorteza A Int J Cardiovasc Imaging; 2017 Aug; 33(8):1253-1261. PubMed ID: 28289990 [TBL] [Abstract][Full Text] [Related]
12. Metal artifact reduction and tumor detection using photon-counting multi-energy computed tomography. Lee CL; Park J; Nam S; Choi J; Choi Y; Lee S; Lee KY; Cho M PLoS One; 2021; 16(3):e0247355. PubMed ID: 33667250 [TBL] [Abstract][Full Text] [Related]
13. Photon counting spectral CT: improved material decomposition with K-edge-filtered x-rays. Shikhaliev PM Phys Med Biol; 2012 Mar; 57(6):1595-615. PubMed ID: 22398007 [TBL] [Abstract][Full Text] [Related]
14. Quarter-millimeter spectral coronary stent imaging with photon-counting CT: Initial experience. Symons R; De Bruecker Y; Roosen J; Van Camp L; Cork TE; Kappler S; Ulzheimer S; Sandfort V; Bluemke DA; Pourmorteza A J Cardiovasc Comput Tomogr; 2018; 12(6):509-515. PubMed ID: 30509378 [TBL] [Abstract][Full Text] [Related]
15. Dual-Contrast Biphasic Liver Imaging With Iodine and Gadolinium Using Photon-Counting Detector Computed Tomography: An Exploratory Animal Study. Ren L; Huber N; Rajendran K; Fletcher JG; McCollough CH; Yu L Invest Radiol; 2022 Feb; 57(2):122-129. PubMed ID: 34411033 [TBL] [Abstract][Full Text] [Related]
16. Reduced Iodinated Contrast Media Administration in Coronary CT Angiography on a Clinical Photon-Counting Detector CT System: A Phantom Study Using a Dynamic Circulation Model. Emrich T; O'Doherty J; Schoepf UJ; Suranyi P; Aquino G; Kloeckner R; Halfmann MC; Allmendinger T; Schmidt B; Flohr T; Varga-Szemes A Invest Radiol; 2023 Feb; 58(2):148-155. PubMed ID: 36165932 [TBL] [Abstract][Full Text] [Related]
17. Comprehensive evaluations of a prototype full field-of-view photon counting CT system through phantom studies. Zhan X; Zhang R; Niu X; Hein I; Budden B; Wu S; Markov N; Clarke C; Qiang Y; Taguchi H; Nomura K; Muramatsu Y; Yu Z; Kobayashi T; Thompson R; Miyazaki H; Nakai H Phys Med Biol; 2023 Aug; 68(17):. PubMed ID: 37506710 [No Abstract] [Full Text] [Related]
18. On the conditioning of basis materials and its impact on multimaterial decomposition-based spectral imaging in photon-counting CT. Tang X; Ren Y Med Phys; 2021 Mar; 48(3):1100-1116. PubMed ID: 33411350 [TBL] [Abstract][Full Text] [Related]
19. Functional imaging of tumor vasculature using iodine and gadolinium-based nanoparticle contrast agents: a comparison of spectral micro-CT using energy integrating and photon counting detectors. Badea CT; Clark DP; Holbrook M; Srivastava M; Mowery Y; Ghaghada KB Phys Med Biol; 2019 Mar; 64(6):065007. PubMed ID: 30708357 [TBL] [Abstract][Full Text] [Related]
20. Feasibility of unconstrained three-material decomposition: imaging an excised human heart using a prototype silicon photon-counting CT detector. Grönberg F; Lundberg J; Sjölin M; Persson M; Bujila R; Bornefalk H; Almqvist H; Holmin S; Danielsson M Eur Radiol; 2020 Nov; 30(11):5904-5912. PubMed ID: 32588212 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]