165 related articles for article (PubMed ID: 37069170)
1. Non-enzymatic glucose sensors composed of trimetallic CuO/Ag/NiO based composite materials.
Naikoo GA; Bano M; Arshad F; Hassan IU; BaOmar F; Alfagih IM; Tambuwala MM
Sci Rep; 2023 Apr; 13(1):6210. PubMed ID: 37069170
[TBL] [Abstract][Full Text] [Related]
2. Non-enzymatic glucose sensor based on a g-C
Lotfi Z; Gholivand MB; Shamsipur M
Anal Biochem; 2021 Mar; 616():114062. PubMed ID: 33285122
[TBL] [Abstract][Full Text] [Related]
3. Porous Cu-NiO modified glass carbon electrode enhanced nonenzymatic glucose electrochemical sensors.
Zhang X; Gu A; Wang G; Huang Y; Ji H; Fang B
Analyst; 2011 Dec; 136(24):5175-80. PubMed ID: 22029045
[TBL] [Abstract][Full Text] [Related]
4. Diabetes Management by Fourth-Generation Glucose Sensors Based on Lemon-Extract-Supported CuO Nanoporous Materials.
Hassan IU
Molecules; 2023 Sep; 28(19):. PubMed ID: 37836606
[TBL] [Abstract][Full Text] [Related]
5. Fabrication and characterization of non-enzymatic glucose sensor based on ternary NiO/CuO/polyaniline nanocomposite.
Ghanbari Kh; Babaei Z
Anal Biochem; 2016 Apr; 498():37-46. PubMed ID: 26778527
[TBL] [Abstract][Full Text] [Related]
6. Electrode designed with a nanocomposite film of CuO Honeycombs/Ag nanoparticles electrogenerated on a magnetic platform as an amperometric glucose sensor.
Baghayeri M; Nodehi M; Amiri A; Amirzadeh N; Behazin R; Iqbal MZ
Anal Chim Acta; 2020 May; 1111():49-59. PubMed ID: 32312396
[TBL] [Abstract][Full Text] [Related]
7. Lemon extract supported green synthesis of bimetallic CuO/Ag nanoporous materials for sensitive detection of vitamin D3.
Naikoo GA; Almashali FM; Habis FAS; Bano M; Rather JA; Hassan IU; Sheikh RA; Kannan P; Alfagih IM; Tambuwala MM
Sci Rep; 2023 Nov; 13(1):20482. PubMed ID: 37993482
[TBL] [Abstract][Full Text] [Related]
8. Reduced graphene oxide decorated on Cu/CuO-Ag nanocomposite as a high-performance material for the construction of a non-enzymatic sensor: Application to the determination of carbaryl and fenamiphos pesticides.
Hashemi P; Karimian N; Khoshsafar H; Arduini F; Mesri M; Afkhami A; Bagheri H
Mater Sci Eng C Mater Biol Appl; 2019 Sep; 102():764-772. PubMed ID: 31147049
[TBL] [Abstract][Full Text] [Related]
9. Non-enzymatic amperometric sensing of glucose by employing sucrose templated microspheres of copper oxide (CuO).
Saraf M; Natarajan K; Mobin SM
Dalton Trans; 2016 Apr; 45(13):5833-40. PubMed ID: 26939895
[TBL] [Abstract][Full Text] [Related]
10. Engineering MOFs derived metal oxide nanohybrids: Towards electrochemical sensing of catechol in tea samples.
Iftikhar T; Aziz A; Ashraf G; Xu Y; Li G; Zhang T; Asif M; Xiao F; Liu H
Food Chem; 2022 Nov; 395():133642. PubMed ID: 35820273
[TBL] [Abstract][Full Text] [Related]
11. Fabrications of the Flexible Non-Enzymatic Glucose Sensors Using Au-CuO-rGO and Au-CuO-rGO-MWCNTs Nanocomposites as Carriers.
Liao SH; Shiau KY; Wang FH; Yang CF
Sensors (Basel); 2023 Sep; 23(19):. PubMed ID: 37836858
[TBL] [Abstract][Full Text] [Related]
12. A high-performance nonenzymatic glucose sensor made of CuO-SWCNT nanocomposites.
Quoc Dung N; Patil D; Jung H; Kim D
Biosens Bioelectron; 2013 Apr; 42():280-6. PubMed ID: 23208099
[TBL] [Abstract][Full Text] [Related]
13. A highly sensitive non-enzymatic glucose sensor based on bimetallic Cu-Ag superstructures.
Li H; Guo CY; Xu CL
Biosens Bioelectron; 2015 Jan; 63():339-346. PubMed ID: 25113052
[TBL] [Abstract][Full Text] [Related]
14. Amplified electrochemical sensor employing CuO/SWCNTs and 1-butyl-3-methylimidazolium hexafluorophosphate for selective analysis of sulfisoxazole in the presence of folic acid.
Karimi-Maleh H; Amini F; Akbari A; Shojaei M
J Colloid Interface Sci; 2017 Jun; 495():61-67. PubMed ID: 28189110
[TBL] [Abstract][Full Text] [Related]
15. A non-enzymatic disposable electrochemical sensor based on surface-modified screen-printed electrode CuO-IL/rGO nanocomposite for a single-step determination of glucose in human urine and electrolyte drinks.
Janmee N; Preechakasedkit P; Rodthongkum N; Chailapakul O; Potiyaraj P; Ruecha N
Anal Methods; 2021 Jul; 13(25):2796-2803. PubMed ID: 34114570
[TBL] [Abstract][Full Text] [Related]
16. Coaxial electrospinning synthesis of size-tunable CuO/NiO hollow heterostructured nanofibers: Towards detection of glucose level in human serum.
Li M; Huan K; Deng D; Yan X; Li Y; Luo L
Colloids Surf B Biointerfaces; 2023 Feb; 222():113047. PubMed ID: 36463609
[TBL] [Abstract][Full Text] [Related]
17. Sensitive and selective non-enzymatic detection of glucose by monodispersed NiO @ S-doped hollow carbon sphere hybrid nanostructures.
Madhuvilakku R; Mariappan R; Alagar S; Piraman S
Anal Chim Acta; 2018 Dec; 1042():93-108. PubMed ID: 30428993
[TBL] [Abstract][Full Text] [Related]
18. CuO nanowire/microflower/nanowire modified Cu electrode with enhanced electrochemical performance for non-enzymatic glucose sensing.
Li C; Yamahara H; Lee Y; Tabata H; Delaunay JJ
Nanotechnology; 2015 Jul; 26(30):305503. PubMed ID: 26159235
[TBL] [Abstract][Full Text] [Related]
19. CdS quantum dots modified CuO inverse opal electrodes for ultrasensitive electrochemical and photoelectrochemical biosensor.
Xia L; Xu L; Song J; Xu R; Liu D; Dong B; Song H
Sci Rep; 2015 Jun; 5():10838. PubMed ID: 26042520
[TBL] [Abstract][Full Text] [Related]
20. Experimental investigation of the electrochemical detection of sulfamethoxazole using copper oxide-MoS
Ramya M; Kumar PS; Rangasamy G; Shankar VU; Rajesh G; Nirmala K
Environ Res; 2023 Jan; 216(Pt 1):114463. PubMed ID: 36208779
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]