These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 37084520)

  • 21. A novel improved method for analysis of 2D diffusion-relaxation data--2D PARAFAC-Laplace decomposition.
    Tønning E; Polders D; Callaghan PT; Engelsen SB
    J Magn Reson; 2007 Sep; 188(1):10-23. PubMed ID: 17596979
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Dependence on T1 of the echo amplitudes from multiple spin-echo sequences with equidistant echoes: simulation studies.
    Fransson A; Ericsson A; Sperber GO
    Magn Reson Imaging; 1993; 11(2):197-205. PubMed ID: 8384283
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Using T
    Monaretto T; Montrazi ET; Moraes TB; Souza AA; Rondeau-Mouro C; Colnago LA
    J Magn Reson; 2020 Feb; 311():106666. PubMed ID: 31846810
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Fourier-transform Carr-Purcell-Meiboom-Gill NMR experiments on polymers in colloidal dispersions: how many polymer molecules per particle?
    Flood C; Cosgrove T; Espidel Y; Welfare E; Howell I; Revell P
    Langmuir; 2008 Aug; 24(15):7875-80. PubMed ID: 18588323
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Rapid measurements of heterogeneity in sandstones using low-field nuclear magnetic resonance.
    Mitchell J
    J Magn Reson; 2014 Mar; 240():52-60. PubMed ID: 24530953
    [TBL] [Abstract][Full Text] [Related]  

  • 26. An evaluation of the TSE MR sequence for time efficient data acquisition in polymer gel dosimetry of applications involving high doses and steep dose gradients.
    Baras P; Seimenis I; Sandilos P; Vlahos L; Bieganski T; Georgiou E; Pantelis E; Papagiannis P; Sakelliou L
    Med Phys; 2005 Nov; 32(11):3339-45. PubMed ID: 16370420
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Mechanisms that contribute to the in vitro relaxation and signal intensity of water in barium sulfate suspensions used as MRI contrast agents.
    Briggs RW; Liebig T; Ballinger JR; Ros PR
    Magn Reson Imaging; 1993; 11(5):635-44. PubMed ID: 8345778
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A modified signal intensity equation of Carr-Purcell-Meiboom-Gill pulse sequence for MR imaging.
    Yamada S; Matsuzawa T; Yamada K; Yoshioka S; Ono S; Hishinuma T
    Tohoku J Exp Med; 1989 Jul; 158(3):203-9. PubMed ID: 2799806
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Rapid multi-echo measurement of brain metabolite T₂ values at 7 T using a single-shot spectroscopic Carr-Purcell-Meiboom-Gill sequence and prior information.
    Ronen I; Ercan E; Webb A
    NMR Biomed; 2013 Oct; 26(10):1291-8. PubMed ID: 23564618
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Assessment of chemical exchange in tryptophan-albumin solution through (19)F multicomponent transverse relaxation dispersion analysis.
    Lin PC
    J Biomol NMR; 2015 Jun; 62(2):121-7. PubMed ID: 25900068
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Recent 1D and 2D TD-NMR Pulse Sequences for Plant Science.
    Monaretto T; Moraes TB; Colnago LA
    Plants (Basel); 2021 Apr; 10(5):. PubMed ID: 33919424
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Expression forms and characteristics of Carr-Purcell-Meiboom-Gill sequence magnetic resonance images.
    Yamada S; Matsuzawa T; Yamada K; Ono S; Hishinuma T
    Tohoku J Exp Med; 1989 Mar; 157(3):185-92. PubMed ID: 2727986
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Fast REDOR with CPMG multiple-echo acquisition.
    Hung I; Gan Z
    J Magn Reson; 2014 Jan; 238():82-6. PubMed ID: 24316818
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Phase incremented echo train acquisition applied to magnetic resonance pore imaging.
    Hertel SA; Galvosas P
    J Magn Reson; 2017 Feb; 275():90-97. PubMed ID: 28024258
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Properties of the phase-alternating phase-shift (PHAPS) multiple spin-echo protocol in MRI: a study of the effects of imperfect RF pulses.
    Fransson A; Ericsson A; Jung B; Sperber GO
    Magn Reson Imaging; 1993; 11(6):771-84. PubMed ID: 8371633
    [TBL] [Abstract][Full Text] [Related]  

  • 36. On resonance phase alternated CWFP sequences for rapid and simultaneous measurement of relaxation times.
    Monaretto T; Andrade FD; Moraes TB; Souza AA; deAzevedo ER; Colnago LA
    J Magn Reson; 2015 Oct; 259():174-8. PubMed ID: 26363504
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Comparison of TSE, TGSE, and CPMG measurement techniques for MR polymer gel dosimetry.
    Bankamp A; Schad LR
    Magn Reson Imaging; 2003 Oct; 21(8):929-39. PubMed ID: 14599544
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Increasing sensitivity of pulse EPR experiments using echo train detection schemes.
    Mentink-Vigier F; Collauto A; Feintuch A; Kaminker I; Tarle V; Goldfarb D
    J Magn Reson; 2013 Nov; 236():117-25. PubMed ID: 24121563
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Suppressing phase decoherence of a single atom qubit with Carr-Purcell-Meiboom-Gill sequence.
    Yu S; Xu P; He X; Liu M; Wang J; Zhan M
    Opt Express; 2013 Dec; 21(26):32130-40. PubMed ID: 24514807
    [TBL] [Abstract][Full Text] [Related]  

  • 40. The effect of wait time on T2 distributions from NMR experiments.
    Lien JR; Chang CT; Kulkarni R; Watson AT
    Magn Reson Imaging; 1998; 16(5-6):663-4. PubMed ID: 9803934
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.