142 related articles for article (PubMed ID: 3708821)
21. Determination of hemoglobin derivatives with IL 282 CO-oximeter as compared with a manual spectrophotometric five-wavelength method.
Zwart A; Buursma A; Oeseburg B; Zijlstra WG
Clin Chem; 1981 Nov; 27(11):1903-7. PubMed ID: 7296841
[TBL] [Abstract][Full Text] [Related]
22. A multi-wavelength spectrophotometric method for the simultaneous determination of five haemoglobin derivatives.
Zwart A; Buursma A; van Kampen EJ; Oeseburg B; van der Ploeg PH; Zijlstra WG
J Clin Chem Clin Biochem; 1981 Jul; 19(7):457-63. PubMed ID: 7328392
[TBL] [Abstract][Full Text] [Related]
23. Determination of Human Hemoglobin Derivatives.
Attia AM; Ibrahim FA; Abd El-Latif NA; Aziz SW; Abdelmottaleb Moussa SA; Elalfy MS
Hemoglobin; 2015; 39(5):371-4. PubMed ID: 26193973
[TBL] [Abstract][Full Text] [Related]
24. Forensic application of rapid analysis of carboxyhemoglobin in blood using an oxygen electrode.
Katsumata Y; Aoki M; Oya M; Suzuki O; Yada S; Okuda J
Forensic Sci Int; 1979; 13(2):151-8. PubMed ID: 447148
[TBL] [Abstract][Full Text] [Related]
25. Simplified determination of carboxyhemoglobin.
Beutler E; West C
Clin Chem; 1984 Jun; 30(6):871-4. PubMed ID: 6723043
[TBL] [Abstract][Full Text] [Related]
26. Interference of methylene blue with CO-Oximetry of hemoglobin derivatives.
Gourlain H; Buneaux F; Borron SW; Gouget B; Levillain P
Clin Chem; 1997 Jun; 43(6 Pt 1):1078-80. PubMed ID: 9191565
[No Abstract] [Full Text] [Related]
27. Evaluation of a quality control material containing hemoglobin for blood gas and pH measurement.
Sprokholt R; van Ooik S; van den Camp RA; Bouma BN; Zijlstra WG; Maas AH
Scand J Clin Lab Invest Suppl; 1987; 188():101-12. PubMed ID: 3482476
[TBL] [Abstract][Full Text] [Related]
28. Simultaneous determination of carboxyhemoglobin and methemoglobin in victims of carbon monoxide poisoning.
Katsumata Y; Aoki M; Oya M; Suzuki O; Yada S
J Forensic Sci; 1980 Jul; 25(3):546-9. PubMed ID: 7400767
[TBL] [Abstract][Full Text] [Related]
29. Hemoglobin pigments. Photometer for oxygen saturation, carboxyhemoglobin, and methemoglobin in capillary blood.
Rem J; Siggaard-Andersen O; Norgaard-Pedersen B; Sorensen S
Clin Chim Acta; 1972 Nov; 42(1):101-8. PubMed ID: 4654845
[No Abstract] [Full Text] [Related]
30. An evaluation of analyzed data of hemoglobin derivatives by CO-Oximeter in medico-legal autopsy.
Higuchi T; Noguchi K; Maeda H
Nihon Hoigaku Zasshi; 1992 Dec; 46(6):416-8. PubMed ID: 1303443
[TBL] [Abstract][Full Text] [Related]
31. Near-patient measurements of methemoglobin, oxygen saturation, and total hemoglobin: evaluation of a new instrument for adult and neonatal intensive care.
Gong AK
Crit Care Med; 1995 Jan; 23(1):193-201. PubMed ID: 7528117
[TBL] [Abstract][Full Text] [Related]
32. Accurate measurements of hemoglobin oxygen saturation, and fractions of carboxyhemoglobin and methemoglobin in fetal blood using Radiometer OSM3: corrections for fetal hemoglobin fraction and pH.
Wimberley PD; Siggaard-Andersen O; Fogh-Andersen N
Scand J Clin Lab Invest Suppl; 1990; 203():235-9. PubMed ID: 1708524
[TBL] [Abstract][Full Text] [Related]
33. A new reagent for the rapid determination of total hemoglobin as hemiglobincyanide in blood containing carboxyhemoglobin.
Sato K; Katsumata Y; Aoki M; Suzuki O; Kido A; Oya M; Yada S
Biochem Med; 1983 Aug; 30(1):78-88. PubMed ID: 6626187
[TBL] [Abstract][Full Text] [Related]
34. Determination of total hemoglobin in forensic blood samples with special reference to carboxyhemoglobin analysis.
Sato K; Tamaki K; Hattori H; Moore CM; Tsutsumi H; Okajima H; Katsumata Y
Forensic Sci Int; 1990 Nov; 48(1):89-96. PubMed ID: 2279722
[TBL] [Abstract][Full Text] [Related]
35. [The effect of hyperbilirubinemia on the measurement of oxygenated hemoglobin (O2Hb), carboxyhemoglobin (COHb) and methemoglobin (MetHb) using multiwavelength oximeters in mixed venous blood].
Lampert R; Brandt L
Anaesthesist; 1993 Oct; 42(10):702-9. PubMed ID: 8250204
[TBL] [Abstract][Full Text] [Related]
36. Evaluation of post-mortem oxymetry with reference to the causes of death.
Maeda H; Fukita K; Oritani S; Ishida K; Zhu BL
Forensic Sci Int; 1997 Jun; 87(3):201-10. PubMed ID: 9248039
[TBL] [Abstract][Full Text] [Related]
37. [A method for determination of methemoglobin in blood containing carboxyhemoglobin].
Sato K
Nihon Hoigaku Zasshi; 1983 Apr; 37(2):133-44. PubMed ID: 6674636
[No Abstract] [Full Text] [Related]
38. Rapid multicomponent analysis of hemoglobin derivatives for controlled antidotal use of methemoglobin-forming agents in cyanide poisoning.
Zijlstra WG; Buursma A
Clin Chem; 1993 Aug; 39(8):1685-9. PubMed ID: 8353957
[TBL] [Abstract][Full Text] [Related]
39. Sulfhaemoglobin. Absorption spectrum, millimolar extinction coefficient at lambda = 620 nm, and interference with the determination of haemoglobin and of haemiglobincy anide.
Dijkhuizen P; Buursma A; Gerding AM; Zijlstra WG
Clin Chim Acta; 1977 Aug; 78(3):479-87. PubMed ID: 884871
[TBL] [Abstract][Full Text] [Related]
40. Spectrophotometric evaluation of hemolysis in plasma by quantification of free oxyhemoglobin, methemoglobin, and methemalbumin in presence of bilirubin.
Heckl C; Lang A; Rühm A; Sroka R; Duffield T; Vogeser M; Paal M
J Biophotonics; 2021 May; 14(5):e202000461. PubMed ID: 33527705
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]