These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

163 related articles for article (PubMed ID: 37092287)

  • 1. Safety, usability, and performance of a wireless left atrial pressure monitoring system in patients with heart failure: the VECTOR-HF trial.
    D'Amario D; Meerkin D; Restivo A; Ince H; Sievert H; Wiese A; Schaefer U; Trani C; Bayes-Genis A; Leyva F; Whinnett ZI; Di Mario C; Jonas M; Manhal H; Amat-Santos IJ; Del Trigo M; Gal TB; Avraham BB; Hasin T; Feickert S; D'Ancona G; Altisent OA; Koren O; Caspi O; Abraham WT; Crea F; Anker SD; Kornowski R; Perl L;
    Eur J Heart Fail; 2023 Jun; 25(6):902-911. PubMed ID: 37092287
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The V-LAP System for Remote Left Atrial Pressure Monitoring of Patients With Heart Failure: Remote Left Atrial Pressure Monitoring.
    Perl L; Meerkin D; D'amario D; Avraham BB; Gal TB; Weitsman T; Hasin T; Ince H; Feickert S; D'ancona G; Schaefer U; Sievert H; Leyva F; Whinnett ZI; Di Mario C; Jonas M; Glikson M; Habib M; Caspi O; Koren O; Abraham WT; Kornowski R; Crea F;
    J Card Fail; 2022 Jun; 28(6):963-972. PubMed ID: 35041933
    [TBL] [Abstract][Full Text] [Related]  

  • 3. One-Year Safety and Clinical Outcomes of a Transcatheter Interatrial Shunt Device for the Treatment of Heart Failure With Preserved Ejection Fraction in the Reduce Elevated Left Atrial Pressure in Patients With Heart Failure (REDUCE LAP-HF I) Trial: A Randomized Clinical Trial.
    Shah SJ; Feldman T; Ricciardi MJ; Kahwash R; Lilly S; Litwin S; Nielsen CD; van der Harst P; Hoendermis E; Penicka M; Bartunek J; Fail PS; Kaye DM; Walton A; Petrie MC; Walker N; Basuray A; Yakubov S; Hummel SL; Chetcuti S; Forde-McLean R; Herrmann HC; Burkhoff D; Massaro JM; Cleland JGF; Mauri L
    JAMA Cardiol; 2018 Oct; 3(10):968-977. PubMed ID: 30167646
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Rationale and Design of the Reduce Elevated Left Atrial Pressure in Patients With Heart Failure (Reduce LAP-HF) Trial.
    Hasenfuss G; Gustafsson F; Kaye D; Shah SJ; Burkhoff D; Reymond MC; Komtebedde J; Hünlich M;
    J Card Fail; 2015 Jul; 21(7):594-600. PubMed ID: 26055211
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Transcatheter Interatrial Shunt Device for the Treatment of Heart Failure With Preserved Ejection Fraction (REDUCE LAP-HF I [Reduce Elevated Left Atrial Pressure in Patients With Heart Failure]): A Phase 2, Randomized, Sham-Controlled Trial.
    Feldman T; Mauri L; Kahwash R; Litwin S; Ricciardi MJ; van der Harst P; Penicka M; Fail PS; Kaye DM; Petrie MC; Basuray A; Hummel SL; Forde-McLean R; Nielsen CD; Lilly S; Massaro JM; Burkhoff D; Shah SJ;
    Circulation; 2018 Jan; 137(4):364-375. PubMed ID: 29142012
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Physician-directed patient self-management in heart failure using left atrial pressure: Interim insights from the VECTOR-HF I and IIa studies.
    Meerkin D; Perl L; Hasin T; Petriashvili S; Kurashvili L; Metreveli M; Ince H; Feickert S; Habib M; Caspi O; Jonas M; Amat-Santos IJ; Bayes-Genis A; Codina P; Koren O; Frydman S; Pachino RM; Anker SD; Abraham WT;
    Eur J Heart Fail; 2024 Aug; 26(8):1814-1823. PubMed ID: 38899626
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A Novel Wireless Left Atrial Pressure Monitoring System for Patients with Heart Failure, First Ex-Vivo and Animal Experience.
    Perl L; Soifer E; Bartunek J; Erdheim D; Köhler F; Abraham WT; Meerkin D
    J Cardiovasc Transl Res; 2019 Aug; 12(4):290-298. PubMed ID: 30604310
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Implantation of an Innovative Intracardiac Microcomputer System for Web-Based Real-Time Monitoring of Heart Failure: Usability and Patients' Attitudes.
    D Ancona G; Murero M; Feickert S; Kaplan H; Öner A; Ortak J; Ince H
    JMIR Cardio; 2021 Apr; 5(1):e21055. PubMed ID: 33881400
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Interatrial Shunting for Heart Failure: Early and Late Results From the First-in-Human Experience With the V-Wave System.
    Rodés-Cabau J; Bernier M; Amat-Santos IJ; Ben Gal T; Nombela-Franco L; García Del Blanco B; Kerner A; Bergeron S; Del Trigo M; Pibarot P; Shkurovich S; Eigler N; Abraham WT
    JACC Cardiovasc Interv; 2018 Nov; 11(22):2300-2310. PubMed ID: 30391390
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A 3-Year Single Center Experience With Left Atrial Pressure Remote Monitoring: The Long and Winding Road.
    Restivo A; D'Amario D; Paglianiti DA; Laborante R; Princi G; Cappannoli L; Iaconelli A; Galli M; Aspromonte N; Locorotondo G; Burzotta F; Trani C; Crea F
    Front Cardiovasc Med; 2022; 9():899656. PubMed ID: 35770220
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Transcatheter InterAtrial Shunt Device for the treatment of heart failure: Rationale and design of the pivotal randomized trial to REDUCE Elevated Left Atrial Pressure in Patients with Heart Failure II (REDUCE LAP-HF II).
    Berry N; Mauri L; Feldman T; Komtebedde J; van Veldhuisen DJ; Solomon SD; Massaro JM; Shah SJ
    Am Heart J; 2020 Aug; 226():222-231. PubMed ID: 32629295
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Safety and efficacy of a wireless pulmonary artery pressure sensor: primary endpoint results of the SIRONA 2 clinical trial.
    Sharif F; Rosenkranz S; Bartunek J; Kempf T; Assmus B; Mahon NG; Mullens W
    ESC Heart Fail; 2022 Oct; 9(5):2862-2872. PubMed ID: 35686479
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A transcatheter intracardiac shunt device for heart failure with preserved ejection fraction (REDUCE LAP-HF): a multicentre, open-label, single-arm, phase 1 trial.
    Hasenfuß G; Hayward C; Burkhoff D; Silvestry FE; McKenzie S; Gustafsson F; Malek F; Van der Heyden J; Lang I; Petrie MC; Cleland JG; Leon M; Kaye DM;
    Lancet; 2016 Mar; 387(10025):1298-304. PubMed ID: 27025436
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Safety and feasibility of pulmonary artery pressure-guided heart failure therapy: rationale and design of the prospective CardioMEMS Monitoring Study for Heart Failure (MEMS-HF).
    Angermann CE; Assmus B; Anker SD; Brachmann J; Ertl G; Köhler F; Rosenkranz S; Tschöpe C; Adamson PB; Böhm M
    Clin Res Cardiol; 2018 Nov; 107(11):991-1002. PubMed ID: 29777373
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Rationale and Design of the Left Atrial Pressure Monitoring to Optimize Heart Failure Therapy Study (LAPTOP-HF).
    Maurer MS; Adamson PB; Costanzo MR; Eigler N; Gilbert J; Gold MR; Klapholz M; Saxon LA; Singh JP; Troughton R; Abraham WT
    J Card Fail; 2015 Jun; 21(6):479-88. PubMed ID: 25921522
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Multicenter registry and test bed for extended outpatient hemodynamic monitoring: the hemodynamic frontiers in heart failure (HF
    Heywood JT; Munshi K; Jordan T; Muse E; Fudim M; Sauer AJ; McDermott M; Shah H; Bhimaraj A; Khedraki R; Robinson MR; McCann P; Volz E; Guha A; Jonsson O; Bhatt KA; Bennett MK; Benjamin TA; Guglin M; Abraham J
    Front Cardiovasc Med; 2023; 10():1321415. PubMed ID: 38094114
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Wireless pulmonary artery haemodynamic monitoring in chronic heart failure: a randomised controlled trial.
    Abraham WT; Adamson PB; Bourge RC; Aaron MF; Costanzo MR; Stevenson LW; Strickland W; Neelagaru S; Raval N; Krueger S; Weiner S; Shavelle D; Jeffries B; Yadav JS;
    Lancet; 2011 Feb; 377(9766):658-66. PubMed ID: 21315441
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Correlation of pulmonary capillary wedge pressure with left atrial pressure in patients with mitral stenosis undergoing balloon valvotomy.
    Vinayakumar D; Bijilesh U; Sajeev CG; Rajesh GN; Bastion C; Kadermuneer P; Haridasan V; Mathew D; George B; Krishnan MN
    Indian Heart J; 2016; 68(2):143-6. PubMed ID: 27133321
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Haemodynamic-guided management of heart failure (GUIDE-HF): a randomised controlled trial.
    Lindenfeld J; Zile MR; Desai AS; Bhatt K; Ducharme A; Horstmanshof D; Krim SR; Maisel A; Mehra MR; Paul S; Sears SF; Sauer AJ; Smart F; Zughaib M; Castaneda P; Kelly J; Johnson N; Sood P; Ginn G; Henderson J; Adamson PB; Costanzo MR
    Lancet; 2021 Sep; 398(10304):991-1001. PubMed ID: 34461042
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Real-world evidence in a national health service: results of the UK CardioMEMS HF System Post-Market Study.
    Cowie MR; Flett A; Cowburn P; Foley P; Chandrasekaran B; Loke I; Critoph C; Gardner RS; Guha K; Betts TR; Carr-White G; Zaidi A; Lim HS; Hayward C; Patwala A; Rogers D; Pettit S; Gazzola C; Henderson J; Adamson PB
    ESC Heart Fail; 2022 Feb; 9(1):48-56. PubMed ID: 34882989
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.