These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

139 related articles for article (PubMed ID: 37092724)

  • 1. Venous Blood Oxygenation Measurements Using TRUST and T2-TRIR MRI During Hypoxic and Hypercapnic Gas Challenges.
    Baas KPA; Vu C; Shen J; Coolen BF; Biemond BJ; Strijkers GJ; Wood JC; Nederveen AJ
    J Magn Reson Imaging; 2023 Dec; 58(6):1903-1914. PubMed ID: 37092724
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparative Analysis of Blood T
    Baas KPA; Coolen BF; Petersen ET; Biemond BJ; Strijkers GJ; Nederveen AJ
    J Magn Reson Imaging; 2022 Aug; 56(2):516-526. PubMed ID: 35077595
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Cerebral OEF quantification: A comparison study between quantitative susceptibility mapping and dual-gas calibrated BOLD imaging.
    Ma Y; Sun H; Cho J; Mazerolle EL; Wang Y; Pike GB
    Magn Reson Med; 2020 Jan; 83(1):68-82. PubMed ID: 31373088
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Measurement of OEF and absolute CMRO2: MRI-based methods using interleaved and combined hypercapnia and hyperoxia.
    Wise RG; Harris AD; Stone AJ; Murphy K
    Neuroimage; 2013 Dec; 83():135-47. PubMed ID: 23769703
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Non-invasive MRI measurements of venous oxygenation, oxygen extraction fraction and oxygen consumption in neonates.
    De Vis JB; Petersen ET; Alderliesten T; Groenendaal F; de Vries LS; van Bel F; Benders MJ; Hendrikse J
    Neuroimage; 2014 Jul; 95():185-92. PubMed ID: 24685437
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Rapid T2- and susceptometry-based CMRO2 quantification with interleaved TRUST (iTRUST).
    Rodgers ZB; Englund EK; Langham MC; Magland JF; Wehrli FW
    Neuroimage; 2015 Feb; 106():441-50. PubMed ID: 25449740
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Hemodynamic and Metabolic Assessment of Neonates With Punctate White Matter Lesions Using Phase-Contrast MRI and T2-Relaxation-Under-Spin-Tagging (TRUST) MRI.
    Qi Y; Liu P; Lin Z; Lu H; Wang X
    Front Physiol; 2018; 9():233. PubMed ID: 29615927
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Diminished cerebral oxygen extraction and metabolic rate in sickle cell disease using T2 relaxation under spin tagging MRI.
    Bush AM; Coates TD; Wood JC
    Magn Reson Med; 2018 Jul; 80(1):294-303. PubMed ID: 29194727
    [TBL] [Abstract][Full Text] [Related]  

  • 9. MRI assessment of cerebral oxygen extraction fraction in the medial temporal lobe.
    Jiang D; Liu P; Lin Z; Hazel K; Pottanat G; Lucke E; Moghekar A; Pillai JJ; Lu H
    Neuroimage; 2023 Feb; 266():119829. PubMed ID: 36565971
    [TBL] [Abstract][Full Text] [Related]  

  • 10. In vivo validation of T2- and susceptibility-based S
    Miao X; Nayak KS; Wood JC
    Magn Reson Med; 2019 Dec; 82(6):2188-2198. PubMed ID: 31250481
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Multi-Parametric Evaluation of Cerebral Hemodynamics in Neonatal Piglets Using Non-Contrast-Enhanced Magnetic Resonance Imaging Methods.
    Liu D; Jiang D; Tekes A; Kulikowicz E; Martin LJ; Lee JK; Liu P; Qin Q
    J Magn Reson Imaging; 2021 Oct; 54(4):1053-1065. PubMed ID: 33955613
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Calibrated fMRI for dynamic mapping of CMRO
    Englund EK; Fernández-Seara MA; Rodríguez-Soto AE; Lee H; Rodgers ZB; Vidorreta M; Detre JA; Wehrli FW
    J Cereb Blood Flow Metab; 2020 Jul; 40(7):1501-1516. PubMed ID: 31394960
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Editorial for "Venous Blood Oxygenation Measurements Using TRUST and T2-TRIR MRI During Hypoxic and Hypercapnic Gas Challenges".
    Saggu R
    J Magn Reson Imaging; 2023 Dec; 58(6):1915-1916. PubMed ID: 37329223
    [No Abstract]   [Full Text] [Related]  

  • 14. Cerebral oxygen extraction fraction: Comparison of dual-gas challenge calibrated BOLD with CBF and challenge-free gradient echo QSM+qBOLD.
    Cho J; Ma Y; Spincemaille P; Pike GB; Wang Y
    Magn Reson Med; 2021 Feb; 85(2):953-961. PubMed ID: 32783233
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Quantification of normal cerebral oxygen extraction and oxygen metabolism by phase-based MRI susceptometry: evaluation of repeatability using two different imaging protocols.
    Kämpe R; Lind E; Ståhlberg F; van Westen D; Knutsson L; Wirestam R
    Clin Physiol Funct Imaging; 2017 Mar; 37(2):211-220. PubMed ID: 26490359
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of cerebral oxygen extraction fraction using ASE and TRUST methods in patients with sickle cell disease and healthy controls.
    Fellah S; Ying C; Wang Y; Guilliams KP; Fields ME; Chen Y; Lewis J; Mirro A; Cohen R; Igwe N; Eldeniz C; Jiang D; Lu H; Powers WJ; Lee JM; Ford AL; An H
    J Cereb Blood Flow Metab; 2024 Aug; 44(8):1404-1416. PubMed ID: 38436254
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Hemodynamic and metabolic changes during hypercapnia with normoxia and hyperoxia using pCASL and TRUST MRI in healthy adults.
    Deckers PT; Bhogal AA; Dijsselhof MB; Faraco CC; Liu P; Lu H; Donahue MJ; Siero JC
    J Cereb Blood Flow Metab; 2022 May; 42(5):861-875. PubMed ID: 34851757
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Measurement of oxygen extraction fraction (OEF): An optimized BOLD signal model for use with hypercapnic and hyperoxic calibration.
    Merola A; Murphy K; Stone AJ; Germuska MA; Griffeth VEM; Blockley NP; Buxton RB; Wise RG
    Neuroimage; 2016 Apr; 129():159-174. PubMed ID: 26801605
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Validation of a new 3D quantitative BOLD based cerebral oxygen extraction mapping.
    Lee H; Xu J; Fernandez-Seara MA; Wehrli FW
    J Cereb Blood Flow Metab; 2024 Jul; 44(7):1184-1198. PubMed ID: 38289876
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Vascular space occupancy asymmetric spin echo (VASO-ASE) for non-invasive quantification of cerebral oxygen extraction fraction.
    Waddle SL; Garza M; Ying C; Davis LT; Jordan LC; An H; Donahue MJ
    Magn Reson Med; 2023 Jul; 90(1):211-221. PubMed ID: 36880522
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.