These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

140 related articles for article (PubMed ID: 37093013)

  • 21. Effect of sample preparation techniques upon single cell chemical imaging: A practical comparison between synchrotron radiation based X-ray fluorescence (SR-XRF) and Nanoscopic Secondary Ion Mass Spectrometry (nano-SIMS).
    De Samber B; De Rycke R; De Bruyne M; Kienhuis M; Sandblad L; Bohic S; Cloetens P; Urban C; Polerecky L; Vincze L
    Anal Chim Acta; 2020 Apr; 1106():22-32. PubMed ID: 32145852
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Reduced acquisition time for L-shell x-ray fluorescence computed tomography using polycapillary x-ray optics.
    Vernekohl D; Ahmad M; Dai X; Zhao W; Cheng K; Xing L
    Med Phys; 2019 Dec; 46(12):5696-5702. PubMed ID: 31512753
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Subpixel resolution in CdTe Timepix3 pixel detectors.
    Khalil M; Dreier ES; Kehres J; Jakubek J; Olsen UL
    J Synchrotron Radiat; 2018 Nov; 25(Pt 6):1650-1657. PubMed ID: 30407174
    [TBL] [Abstract][Full Text] [Related]  

  • 24. BEATS: BEAmline for synchrotron X-ray microTomography at SESAME.
    Iori G; Alzu'bi M; Abbadi A; Al Momani Y; Hasoneh AR; Van Vaerenbergh P; Cudin I; Marcos J; Ahmad A; Mohammad A; Matalgah S; Foudeh I; Al Najdawi M; Amro A; Ur Rehman A; Abugharbiyeh M; Khrais R; Aljadaa A; Nour M; Al Mohammad H; Al Omari F; Salama M; García Fusté MJ; Reyes-Herrera J; Morawe C; Attal M; Kasaei S; Chrysostomou C; Kołodziej T; Boruchowski M; Nowak P; Wiechecki J; Fatima A; Ghigo A; Wawrzyniak AI; Lorentz K; Paolucci G; Lehner F; Krisch M; Stampanoni M; Rack A; Kaprolat A; Lausi A
    J Synchrotron Radiat; 2024 Sep; ():. PubMed ID: 39007825
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Characterization of a submicro-X-ray fluorescence setup on the B16 beamline at Diamond Light Source.
    Rauwolf M; Turyanskaya A; Ingerle D; Szoboszlai N; Pape I; Malandain AW; Fox OJL; Hahn L; Sawhney KJS; Streli C
    J Synchrotron Radiat; 2018 Jul; 25(Pt 4):1189-1195. PubMed ID: 29979181
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Detective quantum efficiency for photon-counting hybrid pixel detectors in the tender X-ray domain: application to Medipix3RX.
    Rinkel J; Magalhães D; Wagner F; Meneau F; Cesar Vicentin F
    J Synchrotron Radiat; 2016 Jan; 23(1):206-13. PubMed ID: 26698065
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Nondestructive Differentiation of Polyester Single White Fibers Using Synchrotron Radiation Microbeam X-ray Fluorescence Spectrometry with Vertical Focusing.
    Nishiwaki Y; Honda S; Yamato T; Kondo R; Kaneda A; Hayakawa S
    J Forensic Sci; 2020 Sep; 65(5):1474-1479. PubMed ID: 32539170
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Polycapillary Optics Based Confocal Micro X-ray Fluorescence and X-ray Absorption Spectroscopy Setup at The European Synchrotron Radiation Facility Collaborative Research Group Dutch-Belgian Beamline, BM26A.
    Bauters S; Tack P; Rudloff-Grund JH; Banerjee D; Longo A; Vekemans B; Bras W; Brenker FE; van Silfhout R; Vincze L
    Anal Chem; 2018 Feb; 90(3):2389-2394. PubMed ID: 29318875
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Sensitivity enhancement of an experimental benchtop x-ray fluorescence imaging system by deploying a single crystal cadmium telluride detector system optimized for high flux x-ray operations.
    Moktan H; Jayarathna S; Cho SH
    Nucl Instrum Methods Phys Res A; 2022 Feb; 1025():. PubMed ID: 35340930
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Development of an attenuation correction method for direct x-ray fluorescence (XRF) imaging utilizing gold L-shell XRF photons.
    Ahmed MF; Yasar S; Cho SH
    Med Phys; 2018 Dec; 45(12):5543-5554. PubMed ID: 30307623
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Characterization of a sCMOS-based high-resolution imaging system.
    Mittone A; Manakov I; Broche L; Jarnias C; Coan P; Bravin A
    J Synchrotron Radiat; 2017 Nov; 24(Pt 6):1226-1236. PubMed ID: 29091066
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Beamline X29: a novel undulator source for X-ray crystallography.
    Shi W; Robinson H; Sullivan M; Abel D; Toomey J; Berman LE; Lynch D; Rosenbaum G; Rakowsky G; Rock L; Nolan B; Shea-McCarthy G; Schneider D; Johnson E; Sweet RM; Chance MR
    J Synchrotron Radiat; 2006 Sep; 13(Pt 5):365-72. PubMed ID: 16924132
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Nondestructive characterization of diseased Chinese chive leaves using X-ray intensity ratios with microbeam synchrotron radiation X-ray fluorescence spectrometry.
    Takahashi T; Nishimura Y; Wada E; Ueno D; Nishiwaki Y
    Anal Sci; 2023 Apr; 39(4):493-501. PubMed ID: 36689087
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Micro X-ray fluorescence (μ-XRF) methodology for quantitative elemental imaging of Al-Zn-Mg-Cu alloys with varying chemical compositions.
    Yang Z; Yang L; Zhao L; Huang D; Li J; Chen X; Shen X; Wang H
    Talanta; 2024 Mar; 269():125407. PubMed ID: 37988824
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Fast X-ray microfluorescence imaging with submicrometer-resolution integrating a Maia detector at beamline P06 at PETRA III.
    Boesenberg U; Ryan CG; Kirkham R; Siddons DP; Alfeld M; Garrevoet J; Núñez T; Claussen T; Kracht T; Falkenberg G
    J Synchrotron Radiat; 2016 Nov; 23(Pt 6):1550-1560. PubMed ID: 27787262
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Set-up and experimental parameters of the protein crystallography beamline at the Brazilian National Synchrotron Laboratory.
    Polikarpov I; Perles LA; de Oliveira RT; Oliva G; Castellano EE; Garratt RC; Craievich A
    J Synchrotron Radiat; 1998 Mar; 5(Pt 2):72-6. PubMed ID: 16687806
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Time-resolved XAS (Bonn-SUT-SLRI) beamline at SLRI.
    Poo-arporn Y; Chirawatkul P; Saengsui W; Chotiwan S; Kityakarn S; Klinkhieo S; Hormes J; Songsiriritthigul P
    J Synchrotron Radiat; 2012 Nov; 19(Pt 6):937-43. PubMed ID: 23093752
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Portal MV imaging with thin-film high-energy current X-ray detectors: A Monte Carlo study.
    Liu B; Zygmanski P; Sajo E
    Med Phys; 2017 Dec; 44(12):6128-6137. PubMed ID: 28976578
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Light output measurements and computational models of microcolumnar CsI scintillators for x-ray imaging.
    Nillius P; Klamra W; Sibczynski P; Sharma D; Danielsson M; Badano A
    Med Phys; 2015 Feb; 42(2):600-605. PubMed ID: 28102604
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Elemental distribution mapping on breast tissue samples.
    Pereira GR; Rocha HS; Anjos MJ; Farias PC; Pérez CA; Lopes RT
    Eur J Radiol; 2008 Dec; 68(3 Suppl):S104-8. PubMed ID: 18614310
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.