These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

189 related articles for article (PubMed ID: 3710182)

  • 1. Device for eliminating corneal light reflections during recording of lateral images with a slit lamp.
    Bocca E; Fonda S; Vecchi D; Baraldi P; de Gregorio F
    Graefes Arch Clin Exp Ophthalmol; 1986; 224(3):281-3. PubMed ID: 3710182
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Depth measurement with the slit-lamp microscope.
    Perkins ES
    Br J Ophthalmol; 1988 May; 72(5):344-7. PubMed ID: 3395593
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Device for slit lamp measurement of the corneal axes].
    Thomas C
    Bull Soc Ophtalmol Fr; 1980 Nov; 80(11):1061-2. PubMed ID: 7460144
    [No Abstract]   [Full Text] [Related]  

  • 4. Intraocular light scatter, reflections, fluorescence and absorption: what we see in the slit lamp.
    van den Berg TJTP
    Ophthalmic Physiol Opt; 2018 Jan; 38(1):6-25. PubMed ID: 29265476
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Tomographic measurements of in vivo cataracts by slit-lamp photography.
    Smith NH; Constad WH; Farnsworth PN; Cinotti AA
    Arch Ophthalmol; 1976 Nov; 94(11):1989-94. PubMed ID: 985174
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A new method for retroillumination photography of cataractous lens opacities.
    Kawara T; Obazawa H
    Am J Ophthalmol; 1980 Aug; 90(2):186-9. PubMed ID: 7425030
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Radius of curvature of ocular fundus measured by slit-lamp photography].
    Mikuni M; Yaoeda H
    Nippon Ganka Gakkai Zasshi; 1971; 75(8):1837-43. PubMed ID: 5165898
    [No Abstract]   [Full Text] [Related]  

  • 8. Simple adaptor using a Zeiss observer tube on a Nikon slit lamp.
    Wessels IF
    Ophthalmic Surg; 1988 May; 19(5):365-7. PubMed ID: 3399268
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Slit-lamp studies of the rhesus monkey eye. I. Survey of the anterior segment.
    Koretz JF; Neider MW; Kaufman PL; Bertasso AM; DeRousseau CJ; Bito LZ
    Exp Eye Res; 1987 Feb; 44(2):307-18. PubMed ID: 3582515
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Suitability of slit lamp retroillumination photographs for classifying cataracts according to 'Lens Opacities Classification System II (LOCS II)'.
    Miglior S; Marighi PE; Orzalesi N
    Curr Eye Res; 1992 Oct; 11(10):971-9. PubMed ID: 1451528
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [An instrument to measure the opacity of the cornea and lens].
    DEKKING HM
    Bull Mem Soc Fr Ophtalmol; 1954; 67():313-7. PubMed ID: 13284595
    [No Abstract]   [Full Text] [Related]  

  • 12. An easy and practical method for toric intraocular lens implantation: marking corneal astigmatic axis at slit-lamp.
    Bayramlar H; Dag Y; Karadag R; Cakici O
    Int Ophthalmol; 2017 Feb; 37(1):179-184. PubMed ID: 27169419
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Telemedical diagnosis of anterior segment eye diseases: validation of digital slit-lamp still images.
    Kumar S; Yogesan K; Constable IJ
    Eye (Lond); 2009 Mar; 23(3):652-60. PubMed ID: 18274557
    [TBL] [Abstract][Full Text] [Related]  

  • 14. An advanced slit-image camera.
    Brown N
    Br J Ophthalmol; 1972 Aug; 56(8):624-31. PubMed ID: 5079412
    [No Abstract]   [Full Text] [Related]  

  • 15. [The observation on lens opacity by polarized photoslit-lamp].
    Yamamoto K
    Nippon Ganka Gakkai Zasshi; 1972 Jun; 76(6):340-3. PubMed ID: 5066222
    [No Abstract]   [Full Text] [Related]  

  • 16. Conversion of lens slit lamp photographs into physical light-scattering units.
    van den Berg TJ; Coppens JC
    Invest Ophthalmol Vis Sci; 1999 Aug; 40(9):2151-7. PubMed ID: 10440273
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Photographic investigation of the human lens and cataract.
    Brown N
    Surv Ophthalmol; 1979; 23(5):307-14. PubMed ID: 462364
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Slit lamp studies on incipient senile cataract. I].
    Oashi K
    Ganka; 1971 Jan; 13(1):26-39. PubMed ID: 5099710
    [No Abstract]   [Full Text] [Related]  

  • 19. A portable slit lamp attachment for examination of donor cornea.
    Lifshitz T; Briscoe D; Sabar R; Yassur Y
    Ophthalmic Surg Lasers; 1997 Mar; 28(3):258-9. PubMed ID: 9076806
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The Oqual: a new device for measuring the optical quality of the anterior segment of the human eye.
    Weale R
    Exp Eye Res; 1992 Sep; 55(3):507-10. PubMed ID: 1426080
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.