These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

149 related articles for article (PubMed ID: 37105993)

  • 21. The effects of screw length on stability of simulated osteoporotic distal radius fractures fixed with volar locking plates.
    Wall LB; Brodt MD; Silva MJ; Boyer MI; Calfee RP
    J Hand Surg Am; 2012 Mar; 37(3):446-53. PubMed ID: 22305729
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Biomechanical Comparison of Bicortical, Unicortical, and Unicortical Far-Cortex-Abutting Screw Fixations in Plated Comminuted Midshaft Clavicle Fractures.
    Croley JS; Morris RP; Amin A; Lindsey RW; Gugala Z
    J Hand Surg Am; 2016 Jun; 41(6):703-11. PubMed ID: 27113909
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Comparison of crossed screw versus plate fixation for radial neck fractures.
    Gutowski CJ; Darvish K; Ilyas AM; Jones CM
    Clin Biomech (Bristol, Avon); 2015 Nov; 30(9):966-70. PubMed ID: 26184087
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Biomechanical comparison of screw-based zones of a spatial subchondral support plate for proximal humerus fractures.
    Jabran A; Peach C; Zou Z; Ren L
    Proc Inst Mech Eng H; 2019 Mar; 233(3):372-382. PubMed ID: 30700217
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Unicortical and bicortical plating in the fixation of comminuted fractures of the clavicle: a biomechanical study.
    Looft JM; Corrêa L; Patel M; Rawlings M; Ackland DC
    ANZ J Surg; 2017 Nov; 87(11):915-920. PubMed ID: 28922701
    [TBL] [Abstract][Full Text] [Related]  

  • 26. How Many Screws Are Needed for Reliable Stability of Extra-articular Nonosteoporotic Distal Radius Fractures Fixed with Volar Locking Plates?
    Jung HS; Jung HS; Baek SH; Lee JS
    Clin Orthop Surg; 2020 Mar; 12(1):22-28. PubMed ID: 32117534
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Biomechanical comparison of screw-based zoning of PHILOS and Fx proximal humerus plates.
    Jabran A; Peach C; Zou Z; Ren L
    BMC Musculoskelet Disord; 2018 Jul; 19(1):253. PubMed ID: 30045716
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Number and locations of screw fixation for volar fixed-angle plating of distal radius fractures: biomechanical study.
    Mehling I; Müller LP; Delinsky K; Mehler D; Burkhart KJ; Rommens PM
    J Hand Surg Am; 2010 Jun; 35(6):885-91. PubMed ID: 20513572
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Calcar screw position in proximal humerus fracture fixation: Don't miss high!
    Mehta S; Chin M; Sanville J; Namdari S; Hast MW
    Injury; 2018 Mar; 49(3):624-629. PubMed ID: 29452734
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Ex vivo biomechanical evaluation of pigeon (Columba livia) cadaver intact humeri and ostectomized humeri stabilized with caudally applied titanium locking plate or stainless steel nonlocking plate constructs.
    Darrow BG; Biskup JJ; Weigel JP; Jones MP; Xie X; Liaw PK; Tharpe JL; Sharma A; Penumadu D
    Am J Vet Res; 2017 May; 78(5):570-578. PubMed ID: 28441055
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Biomechanical analysis of locking plates for fixation of metacarpal shaft fractures: A finite element analysis.
    Zhang JF; Li Y; Huo YX; Yan M; Liang SL; Wang L; Wang BC
    Orthop Traumatol Surg Res; 2022 Dec; 108(8):103340. PubMed ID: 35643362
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Biomechanical comparison of 4 different lateral plate constructs for distal fibula fractures.
    Eckel TT; Glisson RR; Anand P; Parekh SG
    Foot Ankle Int; 2013 Nov; 34(11):1588-95. PubMed ID: 23818460
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Locking plate constructs in subtrochanteric fixation: a biomechanical comparison of LCP screws and AO-nuts.
    Baltes TPA; van der Veen AJ; Blankevoort L; Donders JCE; Kloen P
    J Clin Orthop Trauma; 2021 May; 16():1-6. PubMed ID: 33717935
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A biomechanical comparison of locked plate fixation with percutaneous insertion capability versus the angled blade plate in a subtrochanteric fracture gap model.
    Crist BD; Khalafi A; Hazelwood SJ; Lee MA
    J Orthop Trauma; 2009 Oct; 23(9):622-7. PubMed ID: 19897982
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Numerical simulation and biomechanical analysis of locking screw caps on clavicle locking plates.
    Kim DG; Min Kim S; Kim Y
    Medicine (Baltimore); 2022 Jul; 101(30):e29319. PubMed ID: 35905263
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Biomechanical analysis of blade plate versus locking plate fixation for a proximal humerus fracture: comparison using cadaveric and synthetic humeri.
    Siffri PC; Peindl RD; Coley ER; Norton J; Connor PM; Kellam JF
    J Orthop Trauma; 2006 Sep; 20(8):547-54. PubMed ID: 16990726
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Screw augmentation reduces motion at the bone-implant interface: a biomechanical study of locking plate fixation of proximal humeral fractures.
    Schliemann B; Seifert R; Rosslenbroich SB; Theisen C; Wähnert D; Raschke MJ; Weimann A
    J Shoulder Elbow Surg; 2015 Dec; 24(12):1968-73. PubMed ID: 26255200
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Screws with larger core diameter and lower thread pitch increase the stability of locked plating in osteoporotic proximal humeral fractures.
    Schliemann B; Risse N; Frank A; Müller M; Michel P; Raschke MJ; Katthagen JC
    Clin Biomech (Bristol, Avon); 2019 Mar; 63():21-26. PubMed ID: 30784787
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Finite element analysis of different locking plate fixation methods for the treatment of ulnar head fracture.
    Zhang Y; Shao Q; Yang C; Ai C; Zhou D; Yu Y; Sun G
    J Orthop Surg Res; 2021 Mar; 16(1):191. PubMed ID: 33722253
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Development and Testing of a Novel Locking Pin Cap to Create a Fixed-Angle K-Wire Plate Construct.
    Brogan DM; Tang S; Broz K; Dy CJ
    J Hand Surg Am; 2021 May; 46(5):427.e1-427.e8. PubMed ID: 33358883
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.