These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 3711307)

  • 1. Separation of hemagglutination-inhibiting immunoglobulin M antibody to rubella virus in human serum by high-performance liquid chromatography.
    Kobayashi N; Suzuki M; Nakagawa T; Matumoto M
    J Clin Microbiol; 1986 Jun; 23(6):1143-5. PubMed ID: 3711307
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Demonstration of rubella IgM antibody by indirect fluorescent antibody staining, sucrose density gradient centrifugation and mercaptoethanol reduction.
    Forghani B; Schmidt NJ; Lennette EH
    Intervirology; 1973; 1(1):48-59. PubMed ID: 4204098
    [No Abstract]   [Full Text] [Related]  

  • 3. IgG and IgM antibodies to rubella quantitated by enzyme immunoassay.
    Johnson RB; Jensen FC; Peter CR; Nakamura RM
    J Immunoassay; 1982; 3(2):197-222. PubMed ID: 6762381
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Solid-phase radioimmunoassay of rubella virus immunoglobulin M antibodies: comparison with sucrose density gradient centrifugation test.
    Meurman OH; Viljanen MK; Granfors K
    J Clin Microbiol; 1977 Mar; 5(3):257-62. PubMed ID: 856864
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of different methods for the detection of rubella-specific IgM antibodies.
    Braun R; Doerr HW; Geisen HP; Hornig C; Huschka U; Munk K
    J Med Virol; 1981; 8(3):207-14. PubMed ID: 7035616
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Simple technique for separation of concentrated immunoglobulin M fractions by multi-sample gel chromatography and its application to rubella serodiagnosis.
    Inouye S; Kono R
    J Clin Microbiol; 1981 Feb; 13(2):248-51. PubMed ID: 7204546
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Hemadsorption immunosorbent technique for determination of rubella immunoglobulin M antibody.
    van der Logt JT; van Loon AM; van der Veen J
    J Clin Microbiol; 1981 Mar; 13(3):410-5. PubMed ID: 7016893
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Rapid method to detect rubella immunoglobulin M and immunoglobulin A antibodies.
    Schmitz H; Shimizu H; Kampa D; Doerr HW
    J Clin Microbiol; 1975 Feb; 1(2):132-5. PubMed ID: 1176596
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Rubellavirus-specific IgM- and IgA-antibodies. The indirect immunofluorescence (IF)-technique applied to sera with reduced IgG-concentration.
    Hornsleth A; Leerhoy J; Grauballe P; Spanggaard H
    Acta Pathol Microbiol Scand B Microbiol Immunol; 1974 Oct; 82B(5):742-4. PubMed ID: 4611139
    [No Abstract]   [Full Text] [Related]  

  • 10. A rubella haemagglutination inhibitor simulating antibody.
    Haukenes G
    Acta Pathol Microbiol Scand B Microbiol Immunol; 1973 Dec; 81(6):719-23. PubMed ID: 4521970
    [No Abstract]   [Full Text] [Related]  

  • 11. Comparison of methods for detecting specific IgM antibody in infants with congenital rubella.
    Pattison JR; Jackson CM; Hiscock JA; Cradock-Watson JE; Ridehalgh MK
    J Med Microbiol; 1978 Nov; 11(4):411-8. PubMed ID: 364063
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Use of the ultracentrifuge vertical rotor in the detection of rubella-specific IgM on a sucrose density gradient.
    Luton P; Ridgway GL
    J Clin Pathol; 1979 Sep; 32(9):931-4. PubMed ID: 512054
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Separation of immunoglobulin M (IgM) essentially free of IgG from serum for use in systems requiring assay of IgM-type antibodies without interference from rheumatoid factor.
    Johnson RB; Libby R
    J Clin Microbiol; 1980 Sep; 12(3):451-4. PubMed ID: 7217336
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Persistence of rubellavirus-specific immunoglobulin M and immunoglobulin A antibodies: investigation of successive serum samples with lowered immunoglobulin G concentration.
    Hornsleth A; Leerhoy J; Grauballe P; Spanggaard H
    Infect Immun; 1975 Apr; 11(4):804-8. PubMed ID: 1091553
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Use of a rapid method for determining primary infection by rubella virus].
    Nates S; Ferreira Centeno A; Márquez A; Zapata M
    Rev Argent Microbiol; 1987; 19(4):153-9. PubMed ID: 2845475
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A solid-phase immunosorbent technique for the rapid detection of rubella IgM by haemagglutination inhibition.
    Krech U; Wilhelm JA
    J Gen Virol; 1979 Aug; 44(2):281-6. PubMed ID: 392050
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A simple and rapid method for detection of serum IgM antibodies to the rubella virus hemagglutinin.
    Traavik T
    J Virol Methods; 1982 Jan; 3(6):337-47. PubMed ID: 7085839
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Use of staphylococcal protein A for the detection of rubella virus IgM antibodies].
    Crovari P; Gasparini R; Bono A; Lusian F; Tassi GC
    Boll Ist Sieroter Milan; 1979 Nov; 58(5):371-81. PubMed ID: 553518
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Use of the IgM fraction from patients' sera in general virus serology for diagnostic purposes].
    Wolff MH; Marklein G; Schneweis KE; Stifter G
    Zentralbl Bakteriol Orig A; 1974; 227(1-4):392-400. PubMed ID: 4154618
    [No Abstract]   [Full Text] [Related]  

  • 20. Persistence of specific IgM after natural infection with rubella virus.
    Pattison JR
    Lancet; 1975 Jan; 1(7900):185-7. PubMed ID: 47418
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.