145 related articles for article (PubMed ID: 37122904)
1. The effect of voxelization in Monte Carlo simulation to validate Bragg peak characteristics for a pencil proton beam.
Gungor Price GM; Sarigul N
Rep Pract Oncol Radiother; 2023; 28(1):102-113. PubMed ID: 37122904
[TBL] [Abstract][Full Text] [Related]
2. Experimental depth dose curves of a 67.5 MeV proton beam for benchmarking and validation of Monte Carlo simulation.
Faddegon BA; Shin J; Castenada CM; Ramos-Méndez J; Daftari IK
Med Phys; 2015 Jul; 42(7):4199-210. PubMed ID: 26133619
[TBL] [Abstract][Full Text] [Related]
3. Evaluation of GATE-RTion (GATE/Geant4) Monte Carlo simulation settings for proton pencil beam scanning quality assurance.
Winterhalter C; Taylor M; Boersma D; Elia A; Guatelli S; Mackay R; Kirkby K; Maigne L; Ivanchenko V; Resch AF; Sarrut D; Sitch P; Vidal M; Grevillot L; Aitkenhead A
Med Phys; 2020 Nov; 47(11):5817-5828. PubMed ID: 32967037
[TBL] [Abstract][Full Text] [Related]
4. Benchmarking a GATE/Geant4 Monte Carlo model for proton beams in magnetic fields.
Padilla-Cabal F; Alejandro Fragoso J; Franz Resch A; Georg D; Fuchs H
Med Phys; 2020 Jan; 47(1):223-233. PubMed ID: 31661559
[TBL] [Abstract][Full Text] [Related]
5. An initial systematic study of the linear energy transfer distributions of a proton beam under a transverse magnetic field.
Fujii Y; Ueda H; Umegaki K; Matsuura T
Med Phys; 2022 Mar; 49(3):1839-1852. PubMed ID: 35124798
[TBL] [Abstract][Full Text] [Related]
6. Monte Carlo simulations of ³He ion physical characteristics in a water phantom and evaluation of radiobiological effectiveness.
Taleei R; Guan F; Peeler C; Bronk L; Patel D; Mirkovic D; Grosshans DR; Mohan R; Titt U
Med Phys; 2016 Feb; 43(2):761-76. PubMed ID: 26843239
[TBL] [Abstract][Full Text] [Related]
7. A pencil beam algorithm for magnetic resonance image-guided proton therapy.
Padilla-Cabal F; Georg D; Fuchs H
Med Phys; 2018 May; 45(5):2195-2204. PubMed ID: 29532490
[TBL] [Abstract][Full Text] [Related]
8. Technical Note: Experimental verification of magnetic field-induced beam deflection and Bragg peak displacement for MR-integrated proton therapy.
Schellhammer SM; Gantz S; Lühr A; Oborn BM; Bussmann M; Hoffmann AL
Med Phys; 2018 Jul; 45(7):3429-3434. PubMed ID: 29763970
[TBL] [Abstract][Full Text] [Related]
9. Comparison of penh, fluka, and Geant4/topas for absorbed dose calculations in air cavities representing ionization chambers in high-energy photon and proton beams.
Baumann KS; Horst F; Zink K; Gomà C
Med Phys; 2019 Oct; 46(10):4639-4653. PubMed ID: 31350915
[TBL] [Abstract][Full Text] [Related]
10. Depth dose characteristics of proton beams within therapeutic energy range using the particle therapy simulation framework (PTSim) Monte Carlo technique.
Cai SY; Chao TC; Lin MJ; Tung CJ; Lee CC
Biomed J; 2015; 38(5):408-13. PubMed ID: 26459793
[TBL] [Abstract][Full Text] [Related]
11. A fast method for rescaling voxel S values for arbitrary voxel sizes in targeted radionuclide therapy from a single Monte Carlo calculation.
Fernández M; Hänscheid H; Mauxion T; Bardiès M; Kletting P; Glatting G; Lassmann M
Med Phys; 2013 Aug; 40(8):082502. PubMed ID: 23927347
[TBL] [Abstract][Full Text] [Related]
12. Evaluation of electromagnetic and nuclear scattering models in GATE/Geant4 for proton therapy.
Resch AF; Elia A; Fuchs H; Carlino A; Palmans H; Stock M; Georg D; Grevillot L
Med Phys; 2019 May; 46(5):2444-2456. PubMed ID: 30870583
[TBL] [Abstract][Full Text] [Related]
13. Dosimetric Deviations of Bragg-Peak Position Shifts in Uniform Magnetic Fields for Magnetic Resonance Imaging-Guiding Proton Radiotherapy: A Monte Carlo Study.
Wang X; Pan H; Cheng Q; Wang X; Xu W
Front Public Health; 2021; 9():641915. PubMed ID: 34414150
[No Abstract] [Full Text] [Related]
14. Investigation of the Bragg peak degradation caused by homogeneous and heterogeneous lung tissue substitutes: proton beam experiments and comparison to current clinical dose calculation.
Hranek A; Resch AF; Georg D; Knäusl B
Phys Med Biol; 2020 Dec; 65(24):. PubMed ID: 33171454
[TBL] [Abstract][Full Text] [Related]
15. Proton microbeam radiotherapy with scanned pencil-beams--Monte Carlo simulations.
Kłodowska M; Olko P; Waligórski MP
Phys Med; 2015 Sep; 31(6):621-6. PubMed ID: 25982232
[TBL] [Abstract][Full Text] [Related]
16. Single pencil beam benchmark of a module for Monte Carlo simulation of proton transport in the PENELOPE code.
Verbeek N; Wulff J; Bäumer C; Smyczek S; Timmermann B; Brualla L
Med Phys; 2021 Jan; 48(1):456-476. PubMed ID: 33217026
[TBL] [Abstract][Full Text] [Related]
17. A critical study of different Monte Carlo scoring methods of dose average linear-energy-transfer maps calculated in voxelized geometries irradiated with clinical proton beams.
Cortés-Giraldo MA; Carabe A
Phys Med Biol; 2015 Apr; 60(7):2645-69. PubMed ID: 25768028
[TBL] [Abstract][Full Text] [Related]
18. Optimization of FLASH proton beams using a track-repeating algorithm.
Wang Q; Titt U; Mohan R; Guan F; Zhao Y; Yang M; Yepes P
Med Phys; 2022 Oct; 49(10):6684-6698. PubMed ID: 35900902
[TBL] [Abstract][Full Text] [Related]
19. Analysis of the track- and dose-averaged LET and LET spectra in proton therapy using the geant4 Monte Carlo code.
Guan F; Peeler C; Bronk L; Geng C; Taleei R; Randeniya S; Ge S; Mirkovic D; Grosshans D; Mohan R; Titt U
Med Phys; 2015 Nov; 42(11):6234-47. PubMed ID: 26520716
[TBL] [Abstract][Full Text] [Related]
20. Commissioning and beam characterization of the first gantry-mounted accelerator pencil beam scanning proton system.
Kang M; Pang D
Med Phys; 2020 Aug; 47(8):3496-3510. PubMed ID: 31840264
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]