BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 37124654)

  • 1. Glucose Interference in Serum and Urine Samples with Various Creatinine Concentrations Measured by the Jaffe Kinetic Method.
    Choosongsang P; Bhornsrivathanyou N; Aiadsakun P; Choosongsang P; Bodhikul A; Yamsuwan Y; Sriwimol W; Soonthornpun S
    EJIFCC; 2023 Apr; 34(1):57-65. PubMed ID: 37124654
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison between ADVIA Chemistry systems Enzymatic Creatinine_2 method and ADVIA Chemistry systems Creatinine method (kinetic Jaffe method) for determining creatinine.
    Hermida FJ; Lorenzo MJ; Pérez A; Fernández M; Sagastagoia O; Magadán C
    Scand J Clin Lab Invest; 2014 Oct; 74(7):629-36. PubMed ID: 24988313
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The glucose interference in creatinine measurement using an enzymatic method: effect of creatinine concentrations.
    Kaitwatcharachai C; Kaitwatcharachai S; Aeden J; Wiriyasombat D
    J Med Assoc Thai; 2011 Sep; 94 Suppl 4():S131-4. PubMed ID: 22043580
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Exogenous interferences with Jaffe creatinine assays: addition of sodium dodecyl sulfate to reagent eliminates bilirubin and total protein interference with Jaffe methods.
    Srisawasdi P; Chaichanajarernkul U; Teerakanjana N; Vanavanan S; Kroll MH
    J Clin Lab Anal; 2010; 24(3):123-33. PubMed ID: 20486190
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Reference values for serum creatinine with Jaffe-compensated assay in adult Iranian subjects: Tehran Lipid and Glucose Study.
    Ghasemi A; Azimzadeh I; Zahediasl S; Azizi F
    Arch Iran Med; 2014 Jun; 17(6):394-9. PubMed ID: 24916523
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Results of the recalibration of creatinine measurement with the modular Beckman Coulter Jaffe creatinine method.
    Fillée C; Vranken G; Othmane M; Philippe M; Allaeys JM; Courbe A; Ruelle JL; Peeters R
    Clin Chem Lab Med; 2011 Dec; 49(12):1987-99. PubMed ID: 21801031
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Calcium lactate interference in measuring creatinine in peritoneal dialysis fluids by the Jaffé kinetic method.
    Amici G; Da Rin G; Bardin C; Gatti PL; Calconi G; Bocci C
    Adv Perit Dial; 1996; 12():257-60. PubMed ID: 8865915
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of Jaffé rate assay and enzymatic method for the measurement of creatinine clearance.
    Horio M; Orita Y
    Nihon Jinzo Gakkai Shi; 1996 Jul; 38(7):296-9. PubMed ID: 8741390
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Clinical and Analytical Impact of Moving from Jaffe to Enzymatic Serum Creatinine Methodology.
    Syme NR; Stevens K; Stirling C; McMillan DC; Talwar D
    J Appl Lab Med; 2020 Jul; 5(4):631-642. PubMed ID: 32447368
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of bilirubin interference and accuracy of six creatinine assays compared with isotope dilution-liquid chromatography mass spectrometry.
    Nah H; Lee SG; Lee KS; Won JH; Kim HO; Kim JH
    Clin Biochem; 2016 Feb; 49(3):274-81. PubMed ID: 26519089
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of the impact of delayed centrifugation on the diagnostic performance of serum creatinine as a baseline measure of renal function before antiretroviral treatment.
    Chikomba CE; Padoa CJ; Tanyanyiwa D
    South Afr J HIV Med; 2020; 21(1):1056. PubMed ID: 32832109
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Interference of creatinine measurement in CAPD fluid is dependent on glucose and creatinine concentrations.
    Mak TW; Cheung CK; Cheung CM; Leung CB; Lam CW; Lai KN
    Nephrol Dial Transplant; 1997 Jan; 12(1):184-6. PubMed ID: 9027796
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation and comparison of Abbott Jaffe and enzymatic creatinine methods: Could the old method meet the new requirements?
    Küme T; Sağlam B; Ergon C; Sisman AR
    J Clin Lab Anal; 2018 Jan; 32(1):. PubMed ID: 28205269
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Specificity characteristics of 7 commercial creatinine measurement procedures by enzymatic and Jaffe method principles.
    Greenberg N; Roberts WL; Bachmann LM; Wright EC; Dalton RN; Zakowski JJ; Miller WG
    Clin Chem; 2012 Feb; 58(2):391-401. PubMed ID: 22166253
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A Systematic Review of the Effect of N-Acetylcysteine on Serum Creatinine and Cystatin C Measurements.
    Huang JW; Lahey B; Clarkin OJ; Kong J; Clark E; Kanji S; McCudden C; Akbari A; J W Chow B; Shabana W; Hiremath S
    Kidney Int Rep; 2021 Feb; 6(2):396-403. PubMed ID: 33615065
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Prime time for enzymatic creatinine methods in pediatrics.
    Cobbaert CM; Baadenhuijsen H; Weykamp CW
    Clin Chem; 2009 Mar; 55(3):549-58. PubMed ID: 19168555
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A new commercial method for the enzymatic determination of creatinine in serum and urine evaluated: comparison with a kinetic Jaffé method and isotope dilution-mass spectrometry.
    Lindbäck B; Bergman A
    Clin Chem; 1989 May; 35(5):835-7. PubMed ID: 2541950
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The effect of extremely high glucose concentrations on 21 routine chemistry and thyroid Abbott assays: interference study.
    Çuhadar S; Köseoğlu M; Çinpolat Y; Buğdaycı G; Usta M; Semerci T
    Biochem Med (Zagreb); 2016; 26(1):53-60. PubMed ID: 26981018
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Dopamine infusion at typical infusion rates does not cause interference on plasma creatinine assays.
    Cheng JYK; Ranganatha Subramaniam S; Yu SCY; Lois Choy LY; Kwok JSS
    Pract Lab Med; 2024 May; 40():e00399. PubMed ID: 38812907
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Post-standardization of routine creatinine assays: are they suitable for clinical applications.
    Jassam N; Weykamp C; Thomas A; Secchiero S; Sciacovelli L; Plebani M; Thelen M; Cobbaert C; Perich C; Ricós C; Paula FA; Barth JH
    Ann Clin Biochem; 2017 May; 54(3):386-394. PubMed ID: 27496794
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.