136 related articles for article (PubMed ID: 37142520)
1. Scintigraphic Diagnosis of Acute Pulmonary Embolism: From Basics to Best Practices.
Le Roux PY; Le Pennec R; Salaun PY; Zuckier LS
Semin Nucl Med; 2023 Nov; 53(6):743-751. PubMed ID: 37142520
[TBL] [Abstract][Full Text] [Related]
2. Diagnosis of pulmonary embolus using ventilation/perfusion lung scintigraphy: more than 0.5 segment of ventilation/perfusion mismatch is sufficient.
Howarth DM; Booker JA; Voutnis DD
Intern Med J; 2006 May; 36(5):281-8. PubMed ID: 16650192
[TBL] [Abstract][Full Text] [Related]
3. 99mTc technegas ventilation and perfusion lung scintigraphy for the diagnosis of pulmonary embolus.
Howarth DM; Lan L; Thomas PA; Allen LW
J Nucl Med; 1999 Apr; 40(4):579-84. PubMed ID: 10210216
[TBL] [Abstract][Full Text] [Related]
4. Ventilation Scintigraphy With Radiolabeled Carbon Nanoparticulate Aerosol (Technegas): State-of-the-Art Review and Diagnostic Applications to Pulmonary Embolism During COVID-19 Pandemic.
Le Roux PY; Schafer WM; Blanc-Beguin F; Tulchinsky M
Clin Nucl Med; 2023 Jan; 48(1):8-17. PubMed ID: 36288606
[TBL] [Abstract][Full Text] [Related]
5. Krypton-81m ventilation and technetium-99m macroaggregated albumin perfusion scintigraphy for detection of pulmonary embolism: the first experience in Taiwan.
Cherng SC; Yang SP; Wang YF; Jen TK; Huang WS; Lo AR
Zhonghua Yi Xue Za Zhi (Taipei); 2000 Dec; 63(12):876-84. PubMed ID: 11195138
[TBL] [Abstract][Full Text] [Related]
6. [Value of ventilation scintigraphy in the diagnosis of pulmonary thromboembolism].
Ruiz Hernández G; Maya Martínez M; Carrión Valero F; Castillo Pallarés FJ; Mateo Navarro A; Marín Pardo J
An Med Interna; 1999 Aug; 16(8):389-93. PubMed ID: 10507164
[TBL] [Abstract][Full Text] [Related]
7. Technegas versus (81m)Kr ventilation-perfusion scintigraphy: a comparative study in patients with suspected acute pulmonary embolism.
Hartmann IJ; Hagen PJ; Stokkel MP; Hoekstra OS; Prins MH
J Nucl Med; 2001 Mar; 42(3):393-400. PubMed ID: 11337513
[TBL] [Abstract][Full Text] [Related]
8. Clearance of Tc-99m DTPA aerosol in mismatched and matched pulmonary perfusion defects.
Yilmaz M; Capa G; Durak H; Degirmenci B; Evren I; Sayit E; Uçan ES
Clin Nucl Med; 2001 Feb; 26(2):109-13. PubMed ID: 11201465
[TBL] [Abstract][Full Text] [Related]
9. Tomographic imaging in the diagnosis of pulmonary embolism: a comparison between V/Q lung scintigraphy in SPECT technique and multislice spiral CT.
Reinartz P; Wildberger JE; Schaefer W; Nowak B; Mahnken AH; Buell U
J Nucl Med; 2004 Sep; 45(9):1501-8. PubMed ID: 15347717
[TBL] [Abstract][Full Text] [Related]
10. DTPA aerosol in ventilation/perfusion scintigraphy for diagnosing pulmonary embolism.
Trujillo NP; Pratt JP; Talusani S; Quaife RA; Kumpe D; Lear JL
J Nucl Med; 1997 Nov; 38(11):1781-3. PubMed ID: 9374354
[TBL] [Abstract][Full Text] [Related]
11. Diagnosis of pulmonary embolism with spiral CT as a second procedure following scintigraphy.
van Strijen MJ; de Monyé W; Kieft GJ; Pattynama PM; Huisman MV; Smith SJ; Bloem JL
Eur Radiol; 2003 Jul; 13(7):1501-7. PubMed ID: 12835960
[TBL] [Abstract][Full Text] [Related]
12. Diagnostic evaluation of planar and tomographic ventilation/perfusion lung images in patients with suspected pulmonary emboli.
Bajc M; Olsson CG; Olsson B; Palmer J; Jonson B
Clin Physiol Funct Imaging; 2004 Sep; 24(5):249-56. PubMed ID: 15383080
[TBL] [Abstract][Full Text] [Related]
13. Efficient lung scintigraphy.
Tägil K; Evander E; Wollmer P; Palmer J; Jonson B
Clin Physiol; 2000 Mar; 20(2):95-100. PubMed ID: 10735975
[TBL] [Abstract][Full Text] [Related]
14. Ventilation-perfusion SPECT with 99mTc-DTPA versus Technegas: a head-to-head study in obstructive and nonobstructive disease.
Jögi J; Jonson B; Ekberg M; Bajc M
J Nucl Med; 2010 May; 51(5):735-41. PubMed ID: 20395338
[TBL] [Abstract][Full Text] [Related]
15. EANM guidelines for ventilation/perfusion scintigraphy : Part 1. Pulmonary imaging with ventilation/perfusion single photon emission tomography.
Bajc M; Neilly JB; Miniati M; Schuemichen C; Meignan M; Jonson B;
Eur J Nucl Med Mol Imaging; 2009 Aug; 36(8):1356-70. PubMed ID: 19562336
[TBL] [Abstract][Full Text] [Related]
16. The use of 99Tcm-DTPA aerosol ventilation scintigraphy in the diagnosis of pulmonary embolism.
Buxton-Thomas MS; Wraight EP
Nucl Med Commun; 1984 Jun; 5(6):387-91. PubMed ID: 6397705
[TBL] [Abstract][Full Text] [Related]
17. Ventilation/perfusion lung scintigraphy: what is still needed? A review considering technetium-99m-labeled macro-aggregates of albumin.
Zöphel K; Bacher-Stier C; Pinkert J; Kropp J
Ann Nucl Med; 2009 Jan; 23(1):1-16. PubMed ID: 19205833
[TBL] [Abstract][Full Text] [Related]
18. Evaluation of 99Tcm Technegas ventilation scintigraphy in the diagnosis of pulmonary embolism.
James JM; Herman KJ; Lloyd JJ; Shields RA; Testa HJ; Church S; Stretton TB
Br J Radiol; 1991 Aug; 64(764):711-9. PubMed ID: 1653078
[TBL] [Abstract][Full Text] [Related]
19. Lung Scintigraphy for Pulmonary Embolism Diagnosis in COVID-19 Patients: A Multicenter Study.
Roux PL; Bonnefoy PB; Bahloul A; Denizot B; Barres B; Moreau-Triby C; Girma A; Pallardy A; Ceyrat Q; Sarda-Mantel L; Razzouk-Cadet M; Zsigmond R; Florent C; Karcher G; Salaun PY
J Nucl Med; 2022 Jul; 63(7):1070-1074. PubMed ID: 34649944
[TBL] [Abstract][Full Text] [Related]
20. [Reliability of pulmonary perfusion and ventilation scintigraphy compared with angiopneumography for the diagnosis of pulmonary embolism].
Peltier P; Cesbron JP; Crochet D; Delhumeau J; Dupas B
J Radiol; 1984 Mar; 65(3):183-6. PubMed ID: 6232379
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]