These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

157 related articles for article (PubMed ID: 37152918)

  • 1. Initial experience with a modified "candy-plug" technique for false lumen embolization in chronic type B aortic dissection.
    Miles D; Arbabi C; McMackin K; Tjaden B; Schonefeld S; Baril D; Gupta N; Gewertz B; Azizzadeh A
    J Vasc Surg Cases Innov Tech; 2023 Jun; 9(2):101075. PubMed ID: 37152918
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Open and endovascular reinterventions after Candy Plug false lumen embolization of type B aortic dissection.
    Loschi D; Santoro A; Rinaldi E; Anselmi C; Grignani C; Chiesa R; Melissano G
    J Vasc Surg; 2023 Dec; 78(6):1409-1417. PubMed ID: 37572890
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Candy-Plug Generation II for False Lumen Occlusion in Chronic Aortic Dissection: Feasibility and Early Results.
    Eleshra A; Kölbel T; Tsilimparis N; Panuccio G; Scheerbaum M; Debus ES; Mogensen J; Rohlffs F
    J Endovasc Ther; 2019 Dec; 26(6):782-786. PubMed ID: 31478456
    [No Abstract]   [Full Text] [Related]  

  • 4. False lumen embolization in chronic aortic dissection promotes thoracic aortic remodeling at midterm follow-up.
    Pellenc Q; Roussel A; De Blic R; Girault A; Cerceau P; Ben Abdallah I; Milleron O; Jondeau G; Castier Y
    J Vasc Surg; 2019 Sep; 70(3):710-717. PubMed ID: 30850289
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A modified candy-plug technique to occlude false lumen in aortic dissection.
    Palm E; Valtola A; Manninen H; Saari P
    CVIR Endovasc; 2022 Oct; 5(1):57. PubMed ID: 36308646
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Clinical outcomes and aortic remodeling after Castor single-branched stent-graft implantation for type B aortic dissections involving left subclavian artery.
    Yuan Z; Zhang L; Cai F; Wang J
    Front Cardiovasc Med; 2024; 11():1370908. PubMed ID: 38873267
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The Candy-Plug Technique: Technical Aspects and Early Results of a New Endovascular Method for False Lumen Occlusion in Chronic Aortic Dissection.
    Rohlffs F; Tsilimparis N; Fiorucci B; Heidemann F; Debus ES; Kölbel T
    J Endovasc Ther; 2017 Aug; 24(4):549-555. PubMed ID: 28490232
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Remodeling of Aortic Configuration and Abdominal Aortic Branch Perfusion After Endovascular Repair of Acute Type B Aortic Dissection: A Computed Tomographic Angiography Follow-Up.
    Yuan Z; Li Y; Jin B; Wang J
    Front Cardiovasc Med; 2021; 8():752849. PubMed ID: 34760948
    [No Abstract]   [Full Text] [Related]  

  • 9. Candy-Plug Technique Using an Excluder Aortic Extender for Distal Occlusion of a Large False Lumen Aneurysm in Chronic Aortic Dissection.
    Ogawa Y; Nishimaki H; Chiba K; Murakami K; Sakurai Y; Fujiwara K; Miyairi T; Nakajima Y
    J Endovasc Ther; 2016 Jun; 23(3):483-6. PubMed ID: 27009975
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Coil Embolization for Persistent Thoracic False Lumen of Type B Aortic Dissection after Thoracic Endovascular Aortic Repair.
    Zhang H; Ge YY; Lu K; Cao L; Liu P; Liu XP; Wang LJ; Guo W
    Ann Vasc Surg; 2019 May; 57():60-68. PubMed ID: 30684608
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Clinical Utility of the Candy-Plug Technique Using an Excluder Aortic Extender.
    Ogawa Y; Nishimaki H; Chiba K; Iraha T; Maruhashi T; Sakurai Y; Miyairi T; Nakajima Y
    Ann Vasc Dis; 2021 Jun; 14(2):139-145. PubMed ID: 34239639
    [No Abstract]   [Full Text] [Related]  

  • 12. Outcomes after false lumen embolization with covered stent devices in chronic dissection.
    Idrees J; Roselli EE; Shafii S; Reside J; Lytle BW
    J Vasc Surg; 2014 Dec; 60(6):1507-13. PubMed ID: 25441677
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Homemade Candy Plug Using a Zenith Alpha Thoracic Stent-Graft for False Lumen Distal Occlusion in Acute-on-Chronic Type B Aortic Dissection.
    Yap KH; Tham YC; Tay KH; Tze Tec C; Irani FG; Kian CJ; Chao VTT
    J Endovasc Ther; 2019 Oct; 26(5):732-735. PubMed ID: 31257993
    [No Abstract]   [Full Text] [Related]  

  • 14. Aortic remodeling after endovascular aortic repair and tailored distal entry tears exclusion in Crawford type III or IV dissection aneurysm.
    Fan CY; Chi NH; Wang SS; Chen YS; Chou NK; Wu IH
    J Formos Med Assoc; 2022 Dec; 121(12):2520-2526. PubMed ID: 35717417
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Laser-assisted "Scissor" Technique to Facilitate Thoracic Endovascular Aortic Repair for Chronic Type B Aortic Dissection.
    Qato K; Conway A; Northfield E; Giangola G; Brinster D; Carroccio A
    Ann Vasc Surg; 2021 Nov; 77():347.e7-347.e11. PubMed ID: 34182117
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Endovascular strategies for post-dissection aortic aneurysm (PDAA).
    Zeng Z; Zhao Y; Wu M; Bao X; Li T; Feng J; Feng R; Jing Z
    J Cardiothorac Surg; 2020 Oct; 15(1):287. PubMed ID: 33004048
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Methods and Outcomes of Endovascular False Lumen Embolization for Thoracic Aortic Dissection.
    Li HL; Chan YC; Jia HY; Cheng SW
    Ann Vasc Surg; 2022 Sep; 85():371-382. PubMed ID: 35339592
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Successful Aortic Remodeling Through the Candy-Plug Technique for Chronic Type B Aortic Dissection.
    Shimizu H; Katayama K; Takata Y; Inoue R; Emura S; Takasaki T; Takahashi S
    Vasc Endovascular Surg; 2022 May; ():15385744221095921. PubMed ID: 35532352
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Implications of secondary aortic intervention after thoracic endovascular aortic repair for acute and chronic type B dissection.
    Giles KA; Beck AW; Lala S; Patterson S; Back M; Fatima J; Arnaoutakis DJ; Arnaoutakis GJ; Beaver TM; Berceli SA; Upchurch GR; Huber TS; Scali ST
    J Vasc Surg; 2019 May; 69(5):1367-1378. PubMed ID: 30553732
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Bare Stent Fracture After TEVAR With the Modified Restrictive Bare Stent (RBS) Technique in Type B Aortic Dissections.
    Lescan M; Andic M; Bonorden C; Schano J; Hahn J; Schlensak C; Mustafi M
    J Endovasc Ther; 2023 May; ():15266028231170114. PubMed ID: 37128868
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.