These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

157 related articles for article (PubMed ID: 37184611)

  • 1. A theoretical and experimental investigation on a volume coil with slotted end-rings for rat MRI at 7 T.
    Solis-Najera S; Ruiz R; Martin R; Vazquez F; Marrufo O; Rodriguez AO
    MAGMA; 2023 Dec; 36(6):911-919. PubMed ID: 37184611
    [TBL] [Abstract][Full Text] [Related]  

  • 2. RF coil that minimizes electronic components while enhancing performance for rodent MRI at 7 Tesla.
    Vazquez F; Villareal A; Lazovic J; Martin R; Solis-Najera SE; Rodriguez AO
    Biomed Phys Eng Express; 2024 Sep; 10(5):. PubMed ID: 39173647
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Surface coil with reduced specific absorption rate for rat MRI at 7 T.
    Solis-Najera SE; Martin R; Vazquez F; Rodriguez AO
    MAGMA; 2015 Dec; 28(6):599-608. PubMed ID: 26449714
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A multi-slot surface coil for MRI of dual-rat imaging at 4 T.
    Solis SE; Wang R; Tomasi D; Rodriguez AO
    Phys Med Biol; 2011 Jun; 56(12):3551-61. PubMed ID: 21606551
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An Asymmetric Birdcage Coil for Small-animal MR Imaging at 7T.
    Kim KN; Han SD; Seo JH; Heo P; Yoo D; Im GH; Lee JH
    Magn Reson Med Sci; 2017 Jul; 16(3):253-258. PubMed ID: 27725573
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Optimization of a quadrature birdcage coil for functional imaging of squirrel monkey brain at 9.4T.
    Lu M; Yang Z; Wang F; Drake G; Chen LM; Gore JC; Yan X
    Magn Reson Imaging; 2021 Jun; 79():45-51. PubMed ID: 33741436
    [TBL] [Abstract][Full Text] [Related]  

  • 7. RF shielding designs for birdcage coils for preclinical MRI at 9.4 T.
    Yang Z; Lu M; Drake G; Wang F; Yang PF; Chen LM; Gore JC; Yan X
    Magn Reson Imaging; 2022 Dec; 94():1-6. PubMed ID: 36075493
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Computational analysis of the high pass birdcage resonator: finite difference time domain simulations for high-field MRI.
    Ibrahim TS; Lee R; Baertlein BA; Yu Y; Robitaille PM
    Magn Reson Imaging; 2000 Sep; 18(7):835-43. PubMed ID: 11027877
    [TBL] [Abstract][Full Text] [Related]  

  • 9. 5T magnetic resonance imaging: radio frequency hardware and initial brain imaging.
    Wei Z; Chen Q; Han S; Zhang S; Zhang N; Zhang L; Wang H; He Q; Cao P; Zhang X; Liang D; Liu X; Li Y; Zheng H
    Quant Imaging Med Surg; 2023 May; 13(5):3222-3240. PubMed ID: 37179946
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Design and use of a folded four-ring double-tuned birdcage coil for rat brain sodium imaging at 9.4 T.
    Ha Y; Choi CH; Worthoff WA; Shymanskaya A; Schöneck M; Willuweit A; Felder J; Shah NJ
    J Magn Reson; 2018 Jan; 286():110-114. PubMed ID: 29227914
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Computational and experimental optimization of a double-tuned (1)H/(31)P four-ring birdcage head coil for MRS at 3T.
    Duan Y; Peterson BS; Liu F; Brown TR; Ibrahim TS; Kangarlu A
    J Magn Reson Imaging; 2009 Jan; 29(1):13-22. PubMed ID: 19097097
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Design of a RF-resonant set improving locally the B1+ efficiency. Applications for clinical MRI in andrology and urology.
    Koreshin E; Efimtcev A; Gulko A; Popov S; Orlov I; Trufanov G; Zubkov M
    J Magn Reson; 2020 Aug; 317():106774. PubMed ID: 32589584
    [TBL] [Abstract][Full Text] [Related]  

  • 13. B1 field, SAR, and SNR comparisons for birdcage, TEM, and microstrip coils at 7T.
    Wang C; Shen GX
    J Magn Reson Imaging; 2006 Aug; 24(2):439-43. PubMed ID: 16786582
    [TBL] [Abstract][Full Text] [Related]  

  • 14. High-resolution small field-of-view magnetic resonance image acquisition system using a small planar coil and a pneumatic manipulator in an open MRI scanner.
    Miki K; Masamune K
    Int J Comput Assist Radiol Surg; 2015 Oct; 10(10):1687-97. PubMed ID: 25549798
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Improved SNR for combined TMS-fMRI: A support device for commercially available body array coil.
    Wang WT; Xu B; Butman JA
    J Neurosci Methods; 2017 Sep; 289():1-7. PubMed ID: 28673806
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison and evaluation of mouse cardiac MRI acquired with open birdcage, single loop surface and volume birdcage coils.
    Fan X; Markiewicz EJ; Zamora M; Karczmar GS; Roman BB
    Phys Med Biol; 2006 Dec; 51(24):N451-9. PubMed ID: 17148815
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A dedicated eight-channel receive RF coil array for monkey brain MRI at 9.4 T.
    Li M; Li Y; Jin J; Yang Z; Zhang B; Liu Y; Song M; Freakly C; Weber E; Liu F; Jiang T; Crozier S
    NMR Biomed; 2020 Oct; 33(10):e4369. PubMed ID: 32729642
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A pathway towards a two-dimensional, bore-mounted, volume body coil concept for ultra high-field magnetic resonance imaging.
    Gokyar S; Voss HU; Taracila V; Robb FJL; Bernico M; Kelley D; Ballon DJ; Winkler SA
    NMR Biomed; 2022 Dec; 35(12):e4802. PubMed ID: 35834176
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Monopole antenna array design for 3 T and 7 T magnetic resonance imaging.
    Kausar ASMZ; Reutens DC; Weber E; Vegh V
    PLoS One; 2019; 14(4):e0214637. PubMed ID: 30933999
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Electromagnetic perspective on the operation of RF coils at 1.5-11.7 Tesla.
    Ibrahim TS; Mitchell C; Schmalbrock P; Lee R; Chakeres DW
    Magn Reson Med; 2005 Sep; 54(3):683-90. PubMed ID: 16088934
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.