140 related articles for article (PubMed ID: 37195609)
1. Aerodynamic performance of a ventilation system for droplet control by coughing in a hospital isolation ward.
Song Y; Yang C; Li H; Chen H; Shen S; Hou Y; Wang J
Environ Sci Pollut Res Int; 2023 Jun; 30(29):73812-73824. PubMed ID: 37195609
[TBL] [Abstract][Full Text] [Related]
2. Computational fluid dynamics study on the influence of an alternate ventilation configuration on the possible flow path of infectious cough aerosols in a mock airborne infection isolation room.
Thatiparti DS; Ghia U; Mead KR
Sci Technol Built Environ; 2016; 23(2):355-366. PubMed ID: 28736744
[TBL] [Abstract][Full Text] [Related]
3. The role of air conditioning in the diffusion of Sars-CoV-2 in indoor environments: A first computational fluid dynamic model, based on investigations performed at the Vatican State Children's hospital.
Borro L; Mazzei L; Raponi M; Piscitelli P; Miani A; Secinaro A
Environ Res; 2021 Feb; 193():110343. PubMed ID: 33068577
[TBL] [Abstract][Full Text] [Related]
4. Distribution of droplets/droplet nuclei from coughing and breathing of patients with different postures in a hospital isolation ward.
Liu H; Liu Z; Wang Y; Hu C; Rong R
Build Environ; 2022 Nov; 225():109690. PubMed ID: 36246843
[TBL] [Abstract][Full Text] [Related]
5. Assessing Effectiveness of Ceiling-Ventilated Mock Airborne Infection Isolation Room in Preventing Hospital-Acquired Influenza Transmission to Health Care Workers.
Thatiparti DS; Ghia U; Mead KR
ASHRAE Trans; 2016; 122(2):35-46. PubMed ID: 28529344
[TBL] [Abstract][Full Text] [Related]
6. Behavior of cough droplets emitted from Covid-19 patient in hospital isolation room with different ventilation configurations.
Dao HT; Kim KS
Build Environ; 2022 Feb; 209():108649. PubMed ID: 34898818
[TBL] [Abstract][Full Text] [Related]
7. Role of air distribution in SARS transmission during the largest nosocomial outbreak in Hong Kong.
Li Y; Huang X; Yu IT; Wong TW; Qian H
Indoor Air; 2005 Apr; 15(2):83-95. PubMed ID: 15737151
[TBL] [Abstract][Full Text] [Related]
8. Analysis of Infection Transmission Routes through Exhaled Breath and Cough Particle Dispersion in a General Hospital.
Jung M; Chung WJ; Sung M; Jo S; Hong J
Int J Environ Res Public Health; 2022 Feb; 19(5):. PubMed ID: 35270214
[TBL] [Abstract][Full Text] [Related]
9. The air we breathe: Numerical investigation of ventilation strategies to mitigate airborne dispersion of MERS-CoV in inpatient wards.
Satheesan MK; Tsang TW; Wong LT; Mui KW
Heliyon; 2024 Feb; 10(4):e26159. PubMed ID: 38404798
[TBL] [Abstract][Full Text] [Related]
10. Study on the migration characteristics of bioaerosols and optimization of ventilation patterns in a negative pressure isolation ward considering different patient postures.
Wu D; Chen J; Fu X; Li Z; Tan F; Lin H
PLoS One; 2023; 18(8):e0290288. PubMed ID: 37590299
[TBL] [Abstract][Full Text] [Related]
11. Rethinking hospital general ward ventilation design using computational fluid dynamics.
Yam R; Yuen PL; Yung R; Choy T
J Hosp Infect; 2011 Jan; 77(1):31-6. PubMed ID: 21129819
[TBL] [Abstract][Full Text] [Related]
12. Planning and Design of a Full-Outer-Air-Intake Natural Air-Conditioning System for Medical Negative Pressure Isolation Wards.
Weng CL; Kau LJ
J Healthc Eng; 2021; 2021():8872167. PubMed ID: 33833861
[TBL] [Abstract][Full Text] [Related]
13. The ventilation of multiple-bed hospital wards: review and analysis.
Beggs CB; Kerr KG; Noakes CJ; Hathway EA; Sleigh PA
Am J Infect Control; 2008 May; 36(4):250-9. PubMed ID: 18455045
[TBL] [Abstract][Full Text] [Related]
14. Long-distance airborne dispersal of SARS-CoV-2 in COVID-19 wards.
Nissen K; Krambrich J; Akaberi D; Hoffman T; Ling J; Lundkvist Å; Svensson L; Salaneck E
Sci Rep; 2020 Nov; 10(1):19589. PubMed ID: 33177563
[TBL] [Abstract][Full Text] [Related]
15. Refined design of ventilation systems to mitigate infection risk in hospital wards: Perspective from ventilation openings setting.
Ren C; Wang J; Feng Z; Kim MK; Haghighat F; Cao SJ
Environ Pollut; 2023 Sep; 333():122025. PubMed ID: 37336354
[TBL] [Abstract][Full Text] [Related]
16. Risk assessment of COVID infection by respiratory droplets from cough for various ventilation scenarios inside an elevator: An OpenFOAM-based computational fluid dynamics analysis.
Biswas R; Pal A; Pal R; Sarkar S; Mukhopadhyay A
Phys Fluids (1994); 2022 Jan; 34(1):013318. PubMed ID: 35340680
[TBL] [Abstract][Full Text] [Related]
17. Fate of Exhaled Droplets From Breathing and Coughing in Supermarket Checkouts and Passenger Cars.
Nishandar SR; He Y; Princevac M; Edwards RD
Environ Health Insights; 2023; 17():11786302221148274. PubMed ID: 36644342
[TBL] [Abstract][Full Text] [Related]
18. Impact of HVAC-Systems on the Dispersion of Infectious Aerosols in a Cardiac Intensive Care Unit.
Anghel L; Popovici CG; Stătescu C; Sascău R; Verdeș M; Ciocan V; Șerban IL; Mărănducă MA; Hudișteanu SV; Țurcanu FE
Int J Environ Res Public Health; 2020 Sep; 17(18):. PubMed ID: 32927583
[TBL] [Abstract][Full Text] [Related]
19. Virus diffusion in isolation rooms.
Kao PH; Yang RJ
J Hosp Infect; 2006 Mar; 62(3):338-45. PubMed ID: 16359753
[TBL] [Abstract][Full Text] [Related]
20. Quantitative Microbial Risk Assessment for Airborne Transmission of SARS-CoV-2 via Breathing, Speaking, Singing, Coughing, and Sneezing.
Schijven J; Vermeulen LC; Swart A; Meijer A; Duizer E; de Roda Husman AM
Environ Health Perspect; 2021 Apr; 129(4):47002. PubMed ID: 33793301
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]