These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
6. An L-lactate sensor with immobilized enzyme for use in in vivo studies with an endocrine artificial pancreas. Mascini M; Fortunati S; Moscone D; Palleschi G; Massi-Benedetti M; Fabietti P Clin Chem; 1985 Mar; 31(3):451-3. PubMed ID: 3971566 [TBL] [Abstract][Full Text] [Related]
7. Amperometric lactate oxidase catheter for real-time lactate monitoring based on thin film technology. Pfeiffer D; Möller B; Klimes N; Szeponik J; Fischer S Biosens Bioelectron; 1997; 12(6):539-50. PubMed ID: 9253157 [TBL] [Abstract][Full Text] [Related]
8. Electrochemical assay system with single-use electrode strip for measuring lactate in whole blood. Shimojo N; Naka K; Uenoyama H; Hamamoto K; Yoshioka K; Okuda K Clin Chem; 1993 Nov; 39(11 Pt 1):2312-4. PubMed ID: 8222226 [TBL] [Abstract][Full Text] [Related]
9. L-alpha-glycerophosphate and L-lactate electrodes based on the electrochemical "wiring" of oxidases. Katakis I; Heller A Anal Chem; 1992 May; 64(9):1008-13. PubMed ID: 1590584 [TBL] [Abstract][Full Text] [Related]
10. Determination of serum lactate with alkylamine glass bound lactate oxidase. Suman ; Pundir CS Indian J Biochem Biophys; 2005 Jun; 42(3):186-9. PubMed ID: 23923563 [TBL] [Abstract][Full Text] [Related]
11. Flow injection analysis of L-lactate with enzyme amplification and amperometric detection. Asouzu MU; Nonidez WK; Ho MH Anal Chem; 1990 Apr; 62(7):708-12. PubMed ID: 2327587 [TBL] [Abstract][Full Text] [Related]
12. The use and clinical importance of a substrate-specific electrode for rapid determination of blood lactate concentrations. Aduen J; Bernstein WK; Khastgir T; Miller J; Kerzner R; Bhatiani A; Lustgarten J; Bassin AS; Davison L; Chernow B JAMA; 1994 Dec; 272(21):1678-85. PubMed ID: 7966896 [TBL] [Abstract][Full Text] [Related]
13. Amperometric L-lactate biosensor based on screen-printed carbon electrode containing cobalt phthalocyanine, coated with lactate oxidase-mesoporous silica conjugate layer. Shimomura T; Sumiya T; Ono M; Ito T; Hanaoka TA Anal Chim Acta; 2012 Feb; 714():114-20. PubMed ID: 22244144 [TBL] [Abstract][Full Text] [Related]
14. [Long-functioning beta-D-glucose and L-lactate biosensors for continuous flow-through measurements for "fouling"-resistant and selectivity-optimized serum- and hemoanalysis]. Schindler JG; Schindler MM; Herna K; Pohl M; Guntermann H; Burk B; Reisinger E Eur J Clin Chem Clin Biochem; 1994 Aug; 32(8):599-608. PubMed ID: 7819432 [TBL] [Abstract][Full Text] [Related]
15. Rapid micromeasurement of lactate in whole blood. Clark LC; Noyes LK; Grooms TA; Moore MS Crit Care Med; 1984 May; 12(5):461-4. PubMed ID: 6370602 [TBL] [Abstract][Full Text] [Related]
16. Enzyme sensor for the determination of lactate and lactate dehydrogenase activity. Weigelt D; Schubert F; Scheller F Analyst; 1987 Aug; 112(8):1155-8. PubMed ID: 3662019 [No Abstract] [Full Text] [Related]
17. Determination of urate in undiluted whole blood by enzyme electrode. Keedy FH; Vadgama P Biosens Bioelectron; 1991; 6(6):491-9. PubMed ID: 1910669 [TBL] [Abstract][Full Text] [Related]
18. [O2 sensitive L-lactate biosensors with enzyme membranes based on L-lactate-2-monooxygenase and L-lactate-oxidase with electroanalytic comparison]. Guntermann H; Herna K; Schindler MM; Schindler JG Biomed Tech (Berl); 1996 Oct; 41(10):268-72. PubMed ID: 9019227 [TBL] [Abstract][Full Text] [Related]
19. A catheter-based enzyme-coupled electrode for measurement of lactate. Waite RI; Waite LR; Lim SP; Spieker C Biomed Instrum Technol; 1991; 25(6):461-4. PubMed ID: 1777769 [TBL] [Abstract][Full Text] [Related]
20. Development of an enzymatic assay to measure lactate in perchloric acid-precipitated whole blood. Lu J; Pulsipher BS; Grenache DG Clin Chim Acta; 2015 Apr; 444():208-11. PubMed ID: 25727513 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]