These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Factors influencing the size distribution of aerosols from jet nebulisers. Clay MM; Pavia D; Newman SP; Clarke SW Thorax; 1983 Oct; 38(10):755-9. PubMed ID: 6648854 [TBL] [Abstract][Full Text] [Related]
3. Evaluation of jet nebulisers for use with gentamicin solution. Newman SP; Pellow PG; Clay MM; Clarke SW Thorax; 1985 Sep; 40(9):671-6. PubMed ID: 4060108 [TBL] [Abstract][Full Text] [Related]
4. [Drug Output and Aerosol Characteristics of Different Jet Nebulisers for Adults While Simulating the Nebulisation of Salbutamol]. Walz-Jung H; Krämer I; Kamin W Pneumologie; 2018 Dec; 72(12):820-831. PubMed ID: 30453377 [TBL] [Abstract][Full Text] [Related]
5. Effect of nebulised aerosol size on lung deposition in patients with mild asthma. Clay MM; Clarke SW Thorax; 1987 Mar; 42(3):190-4. PubMed ID: 3303427 [TBL] [Abstract][Full Text] [Related]
6. Comparison of nebuliser efficiency for aerosolizing pentamidine. Smith D; Erskine D; Steele J; Hills D; Gazzard B J Pharm Pharmacol; 1992 Jan; 44(1):7-9. PubMed ID: 1350636 [TBL] [Abstract][Full Text] [Related]
8. Evaluation of droplet dispersion during non-invasive ventilation, oxygen therapy, nebuliser treatment and chest physiotherapy in clinical practice: implications for management of pandemic influenza and other airborne infections. Simonds AK; Hanak A; Chatwin M; Morrell M; Hall A; Parker KH; Siggers JH; Dickinson RJ Health Technol Assess; 2010 Oct; 14(46):131-172. PubMed ID: 20923611 [TBL] [Abstract][Full Text] [Related]
9. Early experience with a vertical spinning-disc nebuliser. Malem H; Ward M; Henry D; Smith WH; Gonda I Lancet; 1981 Sep; 2(8248):644-6. PubMed ID: 6116040 [TBL] [Abstract][Full Text] [Related]
10. Size aspects of metered-dose inhaler aerosols. Kim CS; Trujillo D; Sackner MA Am Rev Respir Dis; 1985 Jul; 132(1):137-42. PubMed ID: 4014858 [TBL] [Abstract][Full Text] [Related]
11. Cooling the NGI - an approach to size a nebulised aerosol more accurately. Dennis J; Berg E; Sandell D; Ali A; Lamb P; Tservistas M; Karlsson M; Mitchell J Pharmeur Sci Notes; 2008 Feb; 2008(1):27-30. PubMed ID: 18430404 [TBL] [Abstract][Full Text] [Related]
12. Choice of nebulisers and compressors for delivery of carbenicillin aerosol. Newman SP; Pellow PG; Clarke SW Eur J Respir Dis; 1986 Sep; 69(3):160-8. PubMed ID: 3780896 [TBL] [Abstract][Full Text] [Related]
13. Evaluation of two commercial jet nebulisers and three compressors for the nebulisation of antibiotics. Hung JC; Hambleton G; Super M Arch Dis Child; 1994 Oct; 71(4):335-8. PubMed ID: 7979528 [TBL] [Abstract][Full Text] [Related]
15. Nebulised pentamidine as treatment for Pneumocystis carinii pneumonia in the acquired immunodeficiency syndrome. Miller RF; Godfrey-Faussett P; Semple SJ Thorax; 1989 Jul; 44(7):565-9. PubMed ID: 2788936 [TBL] [Abstract][Full Text] [Related]
16. Aerosol dispersion of respirable particles in narrow size distributions produced by jet-milling and spray-drying techniques. Louey MD; Van Oort M; Hickey AJ Pharm Res; 2004 Jul; 21(7):1200-6. PubMed ID: 15290860 [TBL] [Abstract][Full Text] [Related]
17. The effects of suspension particle size on the performance of air-jet, ultrasonic and vibrating-mesh nebulisers. Najlah M; Parveen I; Alhnan MA; Ahmed W; Faheem A; Phoenix DA; Taylor KM; Elhissi A Int J Pharm; 2014 Jan; 461(1-2):234-41. PubMed ID: 24275450 [TBL] [Abstract][Full Text] [Related]
18. Comparison of nebulized particle size distribution with Malvern laser diffraction analyzer versus Andersen cascade impactor and low-flow Marple personal cascade impactor. Kwong WT; Ho SL; Coates AL J Aerosol Med; 2000; 13(4):303-14. PubMed ID: 11262437 [TBL] [Abstract][Full Text] [Related]
19. Deposition pattern of droplets from medical nebulizers in the human respiratory tract. Stahlhofen W; Gebhart J; Heyder J; Scheuch G Bull Eur Physiopathol Respir; 1983; 19(5):459-63. PubMed ID: 6640164 [TBL] [Abstract][Full Text] [Related]
20. Assessment of the need to coat particle collection cups of the NGI to mitigate droplet bounce when evaluating nebuliser-produced droplets. Berg E; Lamb P; Ali A; Dennis J; Tservistas M; Mitchell J Pharmeur Sci Notes; 2008 Feb; 2008(1):21-5. PubMed ID: 18430403 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]