These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
147 related articles for article (PubMed ID: 37214307)
1. Biomechanical evaluation of pedicle screw stability after 360-degree turnback from full insertion: effects of screw shape, pilot hole profile and bone density. Li YD; Hsieh MK; Chen WP; Lee DM; Tsai TT; Lai PL; Tai CL Front Bioeng Biotechnol; 2023; 11():1151627. PubMed ID: 37214307 [TBL] [Abstract][Full Text] [Related]
2. Influence of various pilot hole profiles on pedicle screw fixation strength in minimally invasive and traditional spinal surgery: a comparative biomechanical study. Li YD; Lai PL; Hsieh MK; Chen WP; Lee DM; Tsai TT; Tai CL Front Bioeng Biotechnol; 2024; 12():1359883. PubMed ID: 38380264 [TBL] [Abstract][Full Text] [Related]
3. Characteristics of pullout failure in conical and cylindrical pedicle screws after full insertion and back-out. Abshire BB; McLain RF; Valdevit A; Kambic HE Spine J; 2001; 1(6):408-14. PubMed ID: 14588297 [TBL] [Abstract][Full Text] [Related]
4. Biomechanical comparison of pedicle screw fixation strength in synthetic bones: Effects of screw shape, core/thread profile and cement augmentation. Liu MY; Tsai TT; Lai PL; Hsieh MK; Chen LH; Tai CL PLoS One; 2020; 15(2):e0229328. PubMed ID: 32084219 [TBL] [Abstract][Full Text] [Related]
6. Pullout strength of pedicle screws with cement augmentation in severe osteoporosis: a comparative study between cannulated screws with cement injection and solid screws with cement pre-filling. Chen LH; Tai CL; Lee DM; Lai PL; Lee YC; Niu CC; Chen WJ BMC Musculoskelet Disord; 2011 Feb; 12():33. PubMed ID: 21284883 [TBL] [Abstract][Full Text] [Related]
7. Assessment of pedicle screw pullout strength based on various screw designs and bone densities-an ex vivo biomechanical study. Kim YY; Choi WS; Rhyu KW Spine J; 2012 Feb; 12(2):164-8. PubMed ID: 22336467 [TBL] [Abstract][Full Text] [Related]
8. Comparison study of the pullout strength of conventional spinal pedicle screws and a novel design in full and backed-out insertions using mechanical tests. Amaritsakul Y; Chao CK; Lin J Proc Inst Mech Eng H; 2014 Mar; 228(3):250-7. PubMed ID: 24496916 [TBL] [Abstract][Full Text] [Related]
9. The influence of the insertion technique on the pullout force of pedicle screws: an experimental study. Chatzistergos PE; Sapkas G; Kourkoulis SK Spine (Phila Pa 1976); 2010 Apr; 35(9):E332-7. PubMed ID: 20150834 [TBL] [Abstract][Full Text] [Related]
10. Pullout Strength of Pedicle Screws Inserted Using Three Different Techniques: A Biomechanical Study on Polyurethane Foam Block. Wu LC; Hsieh YY; Tsuang FY; Kuo YJ; Chen CH; Chiang CJ Bioengineering (Basel); 2023 May; 10(6):. PubMed ID: 37370591 [TBL] [Abstract][Full Text] [Related]
11. Comparison and prediction of pullout strength of conical and cylindrical pedicle screws within synthetic bone. Tsai WC; Chen PQ; Lu TW; Wu SS; Shih KS; Lin SC BMC Musculoskelet Disord; 2009 Apr; 10():44. PubMed ID: 19402917 [TBL] [Abstract][Full Text] [Related]
12. Probing and Tapping: Are We Inserting Pedicle Screws Correctly? Prasad V; Mesfin A; Lee R; Reigrut J; Schmidt J Spine Deform; 2016 Nov; 4(6):395-399. PubMed ID: 27927567 [TBL] [Abstract][Full Text] [Related]
13. Paravertebral foramen screw fixation for posterior cervical spine fusion: biomechanical study and description of a novel technique. Maki S; Aramomi M; Matsuura Y; Furuya T; Ota M; Iijima Y; Saito J; Suzuki T; Mannoji C; Takahashi K; Yamazaki M; Koda M J Neurosurg Spine; 2017 Oct; 27(4):415-420. PubMed ID: 28498072 [TBL] [Abstract][Full Text] [Related]
14. Augmentation of pedicle screw fixation strength using an injectable calcium phosphate cement as a function of injection timing and method. Renner SM; Lim TH; Kim WJ; Katolik L; An HS; Andersson GB Spine (Phila Pa 1976); 2004 Jun; 29(11):E212-6. PubMed ID: 15167670 [TBL] [Abstract][Full Text] [Related]
16. Mechanical performance of cylindrical and dual-core pedicle screws after repeated insertion. Defino HL; Rosa RC; Silva P; Shimano AC; Albuquerque de Paula FJ; Volpon JB Spine (Phila Pa 1976); 2012 Jun; 37(14):1187-91. PubMed ID: 22880208 [TBL] [Abstract][Full Text] [Related]
17. The Influence of Thread Tap Mismatch on Pedicle Screw Pullout Strength. Pinheiro RP; Miranda RF; Shimano AC; Chandanson T; George K; Defino HLA Rev Bras Ortop (Sao Paulo); 2022 Apr; 57(2):327-333. PubMed ID: 35652034 [No Abstract] [Full Text] [Related]
18. Increasing bending strength and pullout strength in conical pedicle screws: biomechanical tests and finite element analyses. Chao CK; Hsu CC; Wang JL; Lin J J Spinal Disord Tech; 2008 Apr; 21(2):130-8. PubMed ID: 18391719 [TBL] [Abstract][Full Text] [Related]
19. A comparison of pullout strength for pedicle screws of different designs: a study using tapped and untapped pilot holes. Pfeiffer FM; Abernathie DL; Smith DE Spine (Phila Pa 1976); 2006 Nov; 31(23):E867-70. PubMed ID: 17077722 [TBL] [Abstract][Full Text] [Related]
20. Stability and Spine Pedicle Screws Fixation Strength-A Comparative Study of Bone Density and Insertion Angle. Amirouche F; Solitro GF; Magnan BP Spine Deform; 2016 Jul; 4(4):261-267. PubMed ID: 27927514 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]