These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

124 related articles for article (PubMed ID: 3722072)

  • 1. Expiratory flow limitation and dynamic pulmonary hyperinflation during high-frequency ventilation.
    Solway J; Rossing TH; Saari AF; Drazen JM
    J Appl Physiol (1985); 1986 Jun; 60(6):2071-8. PubMed ID: 3722072
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Physiopathology of acute respiratory failure in COPD and asthma].
    Mergoni M; Rossi A
    Minerva Anestesiol; 2001 Apr; 67(4):198-205. PubMed ID: 11376510
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Expiratory airflow limitation and hyperinflation during methacholine-induced bronchoconstriction.
    Pellegrino R; Violante B; Nava S; Rampulla C; Brusasco V; Rodarte JR
    J Appl Physiol (1985); 1993 Oct; 75(4):1720-7. PubMed ID: 8282625
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of prolongation of expiratory time on dynamic hyperinflation in mechanically ventilated patients with severe asthma.
    Leatherman JW; McArthur C; Shapiro RS
    Crit Care Med; 2004 Jul; 32(7):1542-5. PubMed ID: 15241099
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The effects of positive expiratory pressure on isovolume flow and dynamic hyperinflation in patients receiving mechanical ventilation.
    Gay PC; Rodarte JR; Hubmayr RD
    Am Rev Respir Dis; 1989 Mar; 139(3):621-6. PubMed ID: 2647006
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Bedside assessment of the effects of positive end-expiratory pressure on lung inflation and recruitment by the helium dilution technique and electrical impedance tomography.
    Mauri T; Eronia N; Turrini C; Battistini M; Grasselli G; Rona R; Volta CA; Bellani G; Pesenti A
    Intensive Care Med; 2016 Oct; 42(10):1576-1587. PubMed ID: 27518321
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Measurement of static compliance of the total respiratory system in patients with acute respiratory failure during mechanical ventilation. The effect of intrinsic positive end-expiratory pressure.
    Rossi A; Gottfried SB; Zocchi L; Higgs BD; Lennox S; Calverley PM; Begin P; Grassino A; Milic-Emili J
    Am Rev Respir Dis; 1985 May; 131(5):672-7. PubMed ID: 4003913
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Lung hyperinflation and flow limitation in chronic airway obstruction.
    Pellegrino R; Brusasco V
    Eur Respir J; 1997 Mar; 10(3):543-9. PubMed ID: 9072982
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Inspiratory-to-expiratory time ratio and alveolar ventilation during high-frequency ventilation in dogs.
    Yamada Y; Hales CA; Venegas JG
    J Appl Physiol (1985); 1986 Nov; 61(5):1903-7. PubMed ID: 3096949
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of ventilatory variables on gas exchange and hemodynamics during total liquid ventilation in a rat model.
    Matsuda K; Sawada S; Bartlett RH; Hirschl RB
    Crit Care Med; 2003 Jul; 31(7):2034-40. PubMed ID: 12847401
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Increasing the inspiratory time and I:E ratio during mechanical ventilation aggravates ventilator-induced lung injury in mice.
    Müller-Redetzky HC; Felten M; Hellwig K; Wienhold SM; Naujoks J; Opitz B; Kershaw O; Gruber AD; Suttorp N; Witzenrath M
    Crit Care; 2015 Jan; 19(1):23. PubMed ID: 25888164
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Lung hyperinflation in isolated dog lungs during high-frequency oscillation.
    Cha EJ; Chow E; Chang HK; Yamashiro SM
    J Appl Physiol (1985); 1988 Sep; 65(3):1172-9. PubMed ID: 3182488
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effects of ventilatory pattern on hyperinflation, airway pressures, and circulation in mechanical ventilation of patients with severe air-flow obstruction.
    Tuxen DV; Lane S
    Am Rev Respir Dis; 1987 Oct; 136(4):872-9. PubMed ID: 3662241
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [PEEP ventilation without hyperinflation of the lungs. A primary ventilatory pattern of controlled respiration based on expiratory volume curves].
    Lazarus G
    Anaesthesist; 1985 Feb; 34(2):59-64. PubMed ID: 3985301
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Respiratory mechanics of chronic obstructive lung disease in acute respiratory insufficiency].
    Guérin C
    Rev Mal Respir; 1996; 13(2):107-15. PubMed ID: 8711228
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Electrical Impedance Tomography Can Be Used to Quantify Lung Hyperinflation during HFOV: The Pilot Study in Pigs.
    Ort V; Roubik K
    Diagnostics (Basel); 2022 Aug; 12(9):. PubMed ID: 36140483
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Expiratory Flow Limitation During Mechanical Ventilation.
    Junhasavasdikul D; Telias I; Grieco DL; Chen L; Gutierrez CM; Piraino T; Brochard L
    Chest; 2018 Oct; 154(4):948-962. PubMed ID: 29432712
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dynamic hyperinflation and ventilator dependence in chronic obstructive pulmonary disease.
    Kimball WR; Leith DE; Robins AG
    Am Rev Respir Dis; 1982 Dec; 126(6):991-5. PubMed ID: 6960747
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Respiratory Sensations in Dynamic Hyperinflation: Physiological and Clinical Applications.
    Soffler MI; Hayes MM; Schwartzstein RM
    Respir Care; 2017 Sep; 62(9):1212-1223. PubMed ID: 28655742
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Collateral ventilation during high-frequency oscillation in dogs.
    Armengol J; Jones RL; King EG
    J Appl Physiol (1985); 1985 Jan; 58(1):173-9. PubMed ID: 3881381
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.