These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

134 related articles for article (PubMed ID: 37230317)

  • 21. Clinical characteristics and misdiagnosis of spontaneous isolated superior mesenteric artery dissection.
    Lei Y; Liu J; Lin Y; Li H; Song W; Li Z; Huang W; Chen S
    BMC Cardiovasc Disord; 2022 May; 22(1):239. PubMed ID: 35610570
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Modified Petticoat Technique with Pre-placement of a Distal Bare Stent Improves Early Aortic Remodeling after Complicated Acute Stanford Type B Aortic Dissection.
    He H; Yao K; Nie WP; Wang Z; Liang Q; Shu C; Dardik A
    Eur J Vasc Endovasc Surg; 2015 Oct; 50(4):450-9. PubMed ID: 26100449
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Safety and efficacy of conservative, endovascular bare stent and endovascular coil assisting bare stent treatments for patients diagnosed with spontaneous isolated superior mesenteric artery dissection.
    Mkangala AM; Liang H; Dong XJ; Su Y; HaoHao L
    Wideochir Inne Tech Maloinwazyjne; 2020 Dec; 15(4):608-619. PubMed ID: 33294077
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Spontaneous Dissection of Superior Mesenteric Artery: Long-Term Outcome of Stent Placement.
    Kim J; Yoon CJ; Seong N; Lee H; Kim YJ
    J Vasc Interv Radiol; 2017 Dec; 28(12):1722-1726. PubMed ID: 29157477
    [TBL] [Abstract][Full Text] [Related]  

  • 25. The impact of endovascular treatment on clinical outcomes of stable symptomatic patients with spontaneous superior mesenteric artery dissection.
    Gao P; Li G; Chen J; Qiu R; Qiao C; Luo K; Chen S; Wu X; Dong D
    J Vasc Surg; 2021 Apr; 73(4):1269-1276. PubMed ID: 32956796
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Endovascular treatment of superior mesenteric artery pseudoaneurysms using covered stents in six patients.
    Kim SK; Lee J; Duncan JR; Picus DD; Darcy MD; Sauk S
    AJR Am J Roentgenol; 2014 Aug; 203(2):432-8. PubMed ID: 25055281
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Analysis of safety and efficacy of conservative treatment and endovascular treatment in patients with spontaneous isolated mesenteric artery dissection.
    Chen X; Xu L; Xu Z; Fan Z; Huang J; Li J; Zhang Z; Lin C
    Front Surg; 2022; 9():944079. PubMed ID: 36684275
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Endovascular treatment of spontaneous dissections of the superior mesenteric artery.
    Gobble RM; Brill ER; Rockman CB; Hecht EM; Lamparello PJ; Jacobowitz GR; Maldonado TS
    J Vasc Surg; 2009 Dec; 50(6):1326-32. PubMed ID: 19782510
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Correlation of Riolan's arch diameter to treatment choice in patients with isolated superior mesenteric artery dissection.
    Peng Y; Li R; Tang G; Wang K; Sun M; Guan J
    Abdom Radiol (NY); 2022 Oct; 47(10):3628-3637. PubMed ID: 35913506
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Natural Course and Treatment of Symptomatic Spontaneous Isolated Superior Mesenteric Artery Dissection with Total True Lumen Occlusion.
    Huang X; Li G; Zhang X; Chen Z; Xu M; Sun Y
    Vasc Endovascular Surg; 2023 Jan; 57(1):41-47. PubMed ID: 36171181
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Current strategy for the treatment of symptomatic spontaneous isolated dissection of superior mesenteric artery.
    Min SI; Yoon KC; Min SK; Ahn SH; Jae HJ; Chung JW; Ha J; Kim SJ
    J Vasc Surg; 2011 Aug; 54(2):461-6. PubMed ID: 21571493
    [TBL] [Abstract][Full Text] [Related]  

  • 32. The value of a new image classification system for planning treatment and prognosis of spontaneous isolated superior mesenteric artery dissection.
    Xiong J; Wu Z; Guo W; Liu X; Wang L; Zhang H; Jia X; Ma X
    Vascular; 2015 Oct; 23(5):504-12. PubMed ID: 26038122
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Clinical and radiologic course of symptomatic spontaneous isolated dissection of the superior mesenteric artery treated with conservative management.
    Kim HK; Jung HK; Cho J; Lee JM; Huh S
    J Vasc Surg; 2014 Feb; 59(2):465-72. PubMed ID: 24080130
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Relationship Between Morphological Remodeling and Angiographic Types of Spontaneous Isolated Superior Mesenteric Artery Dissection After Conservative Management: Determinant Affecting Serial Radiologic Courses.
    Yuan Z; Sheng S; You Y; Li D; Wei Q; Yan K; Wang J
    Front Cardiovasc Med; 2022; 9():945141. PubMed ID: 35872891
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Endovascular Treatment of Patients with Isolated Mesenteric Artery Dissection Aneurysm: Bare Stents Alone Versus Stent Assisted Coiling.
    Jia Z; Su H; Chen W; Ni G; Qi C; Gu J
    Eur J Vasc Endovasc Surg; 2019 Mar; 57(3):400-406. PubMed ID: 30316568
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Defining Duplex Ultrasound Criteria for In-Stent Restenosis of the Superior Mesenteric Artery.
    Green J; Ryer E; Borden N; Ali B; Garvin R; Yang A; Hashmi A; Salzler G; Elmore J
    Ann Vasc Surg; 2021 Jul; 74():294-300. PubMed ID: 33508454
    [TBL] [Abstract][Full Text] [Related]  

  • 37. [Efficacy of endovascular treatment of distal aortic dissection involving abdominal visceral segment with bare-metal stents related technique].
    Xia SB; Song C; Zhang L; Pei YF; Yuan LX; Li HY; Mao HJ; Lu QS
    Zhonghua Xin Xue Guan Bing Za Zhi; 2021 Apr; 49(4):380-386. PubMed ID: 33874689
    [No Abstract]   [Full Text] [Related]  

  • 38. Endovascular management for isolated spontaneous dissection of the superior mesenteric artery: report of two cases and literature review.
    Lim EH; Jung SW; Lee SH; Kwon BS; Park JY; Koo JS; Yim HJ; Lee SW; Choi JH
    J Vasc Interv Radiol; 2011 Aug; 22(8):1206-11. PubMed ID: 21801996
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Relief of mesenteric ischemia by Z-stent placement into the superior mesenteric artery compressed by the false lumen of an aortic dissection.
    Yamakado K; Takeda K; Nomura Y; Kato N; Hirano T; Matsumura K; Nakagawa T; Yuasa H; Yada I
    Cardiovasc Intervent Radiol; 1998; 21(1):66-8. PubMed ID: 9473550
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Clinical analysis and literature review of a complicated superior mesenteric artery stenosis with intestinal necrosis: A case report.
    Zhou B; Huang J; Chen X; Lin C; Xia Y; Jiang R
    Medicine (Baltimore); 2023 Apr; 102(17):e33586. PubMed ID: 37115070
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.