These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

191 related articles for article (PubMed ID: 37241275)

  • 1. Corrosion Resistance and Titanium Ion Release of Hybrid Dental Implants.
    Robles D; Brizuela A; Fernández-Domínguez M; Gil J
    Materials (Basel); 2023 May; 16(10):. PubMed ID: 37241275
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The Effect of Implantoplasty on the Fatigue Behavior and Corrosion Resistance in Titanium Dental Implants.
    Fonseca D; de Tapia B; Pons R; Aparicio C; Guerra F; Messias A; Gil J
    Materials (Basel); 2024 Jun; 17(12):. PubMed ID: 38930312
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Corrosion Behavior of Titanium Dental Implants with Implantoplasty.
    Lozano P; Peña M; Herrero-Climent M; Rios-Santos JV; Rios-Carrasco B; Brizuela A; Gil J
    Materials (Basel); 2022 Feb; 15(4):. PubMed ID: 35208101
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of Implantoplasty on Roughness, Fatigue and Corrosion Behavior of Narrow Diameter Dental Implants.
    Camps-Font O; Toledano-Serrabona J; Juiz-Camps A; Gil J; Sánchez-Garcés MA; Figueiredo R; Gay-Escoda C; Valmaseda-Castellón E
    J Funct Biomater; 2023 Jan; 14(2):. PubMed ID: 36826860
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The Characterization of Titanium Particles Released from Bone-Level Titanium Dental Implants: Effect of the Size of Particles on the Ion Release and Cytotoxicity Behaviour.
    Callejas JA; Brizuela A; Ríos-Carrasco B; Gil J
    Materials (Basel); 2022 May; 15(10):. PubMed ID: 35629663
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The effect of three dental cement types on the corrosion of dental implant surfaces.
    Alhamad M; Barão VAR; Sukotjo C; Mathew MT
    Heliyon; 2024 Jan; 10(1):e23626. PubMed ID: 38192807
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The role of bacterial corrosion on recolonization of titanium implant surfaces: An in vitro study.
    Weller J; Vasudevan P; Kreikemeyer B; Ekat K; Jackszis M; Springer A; Chatzivasileiou K; Lang H
    Clin Implant Dent Relat Res; 2022 Oct; 24(5):664-675. PubMed ID: 35709098
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Influence of Titanium Surface Residual Stresses on Osteoblastic Response and Bacteria Colonization.
    Pereira R; Maia P; Rios-Santos JV; Herrero-Climent M; Rios-Carrasco B; Aparicio C; Gil J
    Materials (Basel); 2024 Apr; 17(7):. PubMed ID: 38612139
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Electrochemical properties of suprastructures galvanically coupled to a titanium implant.
    Oh KT; Kim KN
    J Biomed Mater Res B Appl Biomater; 2004 Aug; 70(2):318-31. PubMed ID: 15264315
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Stress and electrochemical corrosion of titanium produced by laser rapid forming].
    Zhu JF; Gan K; Du TF; Gao B
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2019 Apr; 54(4):257-262. PubMed ID: 30955298
    [No Abstract]   [Full Text] [Related]  

  • 11. Osteoblastic and Bacterial Response of Hybrid Dental Implants.
    Robles D; Brizuela A; Fernández-Domínguez M; Gil J
    J Funct Biomater; 2023 Jun; 14(6):. PubMed ID: 37367285
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Surface damage of dental implant systems and ions release after exposure to fluoride and hydrogen peroxide.
    Peñarrieta-Juanito G; Sordi MB; Henriques B; Dotto MER; Teughels W; Silva FS; Magini RS; Souza JCM
    J Periodontal Res; 2019 Feb; 54(1):46-52. PubMed ID: 30368813
    [TBL] [Abstract][Full Text] [Related]  

  • 13. In Vitro Investigation of the Effect of Oral Bacteria in the Surface Oxidation of Dental Implants.
    Sridhar S; Wilson TG; Palmer KL; Valderrama P; Mathew MT; Prasad S; Jacobs M; Gindri IM; Rodrigues DC
    Clin Implant Dent Relat Res; 2015 Oct; 17 Suppl 2():e562-75. PubMed ID: 25622914
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Reduction of Tribocorrosion Products When Using the Platform-Switching Concept.
    Alrabeah GO; Knowles JC; Petridis H
    J Dent Res; 2018 Aug; 97(9):995-1002. PubMed ID: 29578825
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Unpredictable Electrochemical Processes in Ti Dental Implants: The Role of Ti Ions and Inflammatory Products.
    Alhamad M; Barão VA; Sukotjo C; Yerokhin A; Mathew MT
    ACS Appl Bio Mater; 2023 Sep; 6(9):3661-3673. PubMed ID: 37602778
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A Literature Review Study on Atomic Ions Dissolution of Titanium and Its Alloys in Implant Dentistry.
    Noumbissi S; Scarano A; Gupta S
    Materials (Basel); 2019 Jan; 12(3):. PubMed ID: 30682826
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of Corrosion Products From Implant and Various Gold-Based Abutment Couplings: The Effect of Gold Plating.
    Silva MD; Walton TR; Alrabeah GO; Layton DM; Petridis H
    J Oral Implantol; 2021 Oct; 47(5):370-379. PubMed ID: 33263748
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Corrosion behaviors of TiO2 nanotube layers on titanium in Hank's solution.
    Yu WQ; Qiu J; Xu L; Zhang FQ
    Biomed Mater; 2009 Dec; 4(6):065012. PubMed ID: 20009163
    [TBL] [Abstract][Full Text] [Related]  

  • 19. In Vitro Evaluation of the Effects of Multiple Oral Factors on Dental Implants Surfaces.
    Sridhar S; Abidi Z; Wilson TG; Valderrama P; Wadhwani C; Palmer K; Rodrigues DC
    J Oral Implantol; 2016 Jun; 42(3):248-57. PubMed ID: 26829492
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Corrosion behaviour of commercially pure titanium shot blasted with different materials and sizes of shot particles for dental implant applications.
    Aparicio C; Gil FJ; Fonseca C; Barbosa M; Planell JA
    Biomaterials; 2003 Jan; 24(2):263-73. PubMed ID: 12419627
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.