These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

108 related articles for article (PubMed ID: 37260765)

  • 1. Mathematical Modeling of the Effect of Temperature on the Dynamic Characteristics of a Cantilever Beam with Flexible Root.
    Mohammed Sarhan S; Al-Zubaidi S
    ScientificWorldJournal; 2023; 2023():6568120. PubMed ID: 37260765
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The porous cantilever beam as a model for spinal implants: Experimental, analytical and finite element analysis of dynamic properties.
    Du X; Zhou Y; Li L; Persson C; Ferguson SJ
    Math Biosci Eng; 2023 Jan; 20(4):6273-6293. PubMed ID: 37161106
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An Empirical Torsional Spring Model for the Inclined Crack in a 3D-Printed Acrylonitrile Butadiene Styrene (ABS) Cantilever Beam.
    Yang Z; He F; Khan M
    Polymers (Basel); 2023 Jan; 15(3):. PubMed ID: 36771797
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Closed form solution of nonlinear oscillation of a cantilever beam using
    Mara'Beh RA; Al-Dweik AY; Yilbas BS; Sunar M
    Heliyon; 2022 Nov; 8(11):e11673. PubMed ID: 36439727
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A novel method and system for calibrating the spring constant of atomic force microscope cantilever based on electromagnetic actuation.
    Tian Y; Zhou C; Wang F; Zhang J; Guo Z; Zhang D
    Rev Sci Instrum; 2018 Dec; 89(12):125119. PubMed ID: 30599581
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Calibration of the torsional and lateral spring constants of cantilever sensors.
    Parkin JD; Hähner G
    Nanotechnology; 2014 Jun; 25(22):225701. PubMed ID: 24807706
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Experimental and theoretical studies of frequency response function of dagger-shaped atomic force microscope cantilever in different immersion environments.
    Gholizadeh Pasha AH; Sadeghi A
    J Microsc; 2020 Jul; 279(1):52-68. PubMed ID: 32282936
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Research on a Precision Calibration Model of a Flexible Strain Sensor Based on a Variable Section Cantilever Beam.
    Wang Q; Cui J; Tang Y; Pang L; Chen K; Zhang B
    Sensors (Basel); 2023 May; 23(10):. PubMed ID: 37430692
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Theoretical Study on the Dynamic Behavior of a Plate-Like Micro-Cantilever with Multiple Particles Attached.
    Zhao L; Wang F; Zhang Y; Zhao X
    PLoS One; 2016; 11(3):e0151821. PubMed ID: 27023056
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Nondestructive experimental determination of bimaterial rectangular cantilever spring constants in water.
    Snow DE; Weeks BL; Kim DJ; Pitchimani R; Hope-Weeks LJ
    Rev Sci Instrum; 2008 Aug; 79(8):083706. PubMed ID: 19044356
    [TBL] [Abstract][Full Text] [Related]  

  • 11. In-Situ Dynamic Response Measurement for Damage Quantification of 3D Printed ABS Cantilever Beam under Thermomechanical Load.
    Baqasah H; He F; Zai BA; Asif M; Khan KA; Thakur VK; Khan MA
    Polymers (Basel); 2019 Dec; 11(12):. PubMed ID: 31842417
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The Force-Frequency Characteristics of Quartz Wafers under a Cantilever Beam Structure.
    Shen J; Chen CY; Wu CY; Cheng J; Chao MC; Zhou Q; Lu C
    Sensors (Basel); 2024 May; 24(11):. PubMed ID: 38894150
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Interdependencies between Dynamic Response and Crack Growth in a 3D-Printed Acrylonitrile Butadiene Styrene (ABS) Cantilever Beam under Thermo-Mechanical Loads.
    He F; Khan M; Aldosari S
    Polymers (Basel); 2022 Feb; 14(5):. PubMed ID: 35267804
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Isospectrals of non-uniform Rayleigh beams with respect to their uniform counterparts.
    Bhat K S; Ganguli R
    R Soc Open Sci; 2018 Feb; 5(2):171717. PubMed ID: 29515879
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Resonance frequencies of AFM cantilevers in contact with a surface.
    Verbiest GJ; Rost MJ
    Ultramicroscopy; 2016 Dec; 171():70-76. PubMed ID: 27615394
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effects of anisotropic material property on the spring constant and the resonant frequency of atomic force microscope cantilever.
    Yeh MK; Tai NH; Chen BY
    Rev Sci Instrum; 2009 Apr; 80(4):043705. PubMed ID: 19405664
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Influence of Hole Localization on Local and Global Dynamic Response of Thin-Walled Laminated Cantilever Beam.
    Bochenski M; Gawryluk J; Teter A
    Materials (Basel); 2021 Dec; 14(23):. PubMed ID: 34885564
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Hydrodynamic damping of a magnetically oscillated cantilever close to a surface.
    Rankl C; Pastushenko V; Kienberger F; Stroh CM; Hinterdorfer P
    Ultramicroscopy; 2004 Aug; 100(3-4):301-8. PubMed ID: 15231323
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A New Analytical Model to Estimate the Voltage Value and Position of the Pull-In Limit of a MEMS Cantilever.
    Ak C; Yildiz A
    Micromachines (Basel); 2016 Mar; 7(4):. PubMed ID: 30407425
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Deflection, frequency, and stress characteristics of rectangular, triangular, and step profile microcantilevers for biosensors.
    Ansari MZ; Cho C
    Sensors (Basel); 2009; 9(8):6046-57. PubMed ID: 22454571
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.