These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 37273141)

  • 1. Poly(para toluene sulphonic acid) and gold nanoparticles modified glassy carbon electrode for simultaneous voltammetric sensing of xanthine and hypoxanthine.
    Mathew MR; Anand SK; Kumar KG
    Anal Sci; 2023 Oct; 39(10):1693-1701. PubMed ID: 37273141
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Simultaneous determination of uric acid, xanthine and hypoxanthine at poly(pyrocatechol violet)/functionalized multi-walled carbon nanotubes composite film modified electrode.
    Wang Y
    Colloids Surf B Biointerfaces; 2011 Dec; 88(2):614-21. PubMed ID: 21856133
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An ultrasensitive electrochemical sensor for simultaneous determination of xanthine, hypoxanthine and uric acid based on Co doped CeO2 nanoparticles.
    Lavanya N; Sekar C; Murugan R; Ravi G
    Mater Sci Eng C Mater Biol Appl; 2016 Aug; 65():278-86. PubMed ID: 27157753
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Simultaneous Determination of Xanthine and Hypoxanthine Using Polyglycine/rGO-Modified Glassy Carbon Electrode.
    Wang T; Zhang L; Zhang C; Deng D; Wang D; Luo L
    Molecules; 2023 Feb; 28(3):. PubMed ID: 36771122
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Examination of performance of glassy carbon paste electrode modified with gold nanoparticle and xanthine oxidase for xanthine and hypoxanthine detection.
    Cubukçu M; Timur S; Anik U
    Talanta; 2007 Dec; 74(3):434-9. PubMed ID: 18371660
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Simultaneous electrochemical determination of uric acid, xanthine and hypoxanthine based on poly(L-arginine)/graphene composite film modified electrode.
    Zhang F; Wang Z; Zhang Y; Zheng Z; Wang C; Du Y; Ye W
    Talanta; 2012 May; 93():320-5. PubMed ID: 22483917
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A non-enzymatic voltammetric xanthine sensor based on the use of platinum nanoparticles loaded with a metal-organic framework of type MIL-101(Cr). Application to simultaneous detection of dopamine, uric acid, xanthine and hypoxanthine.
    Zhang L; Li S; Xin J; Ma H; Pang H; Tan L; Wang X
    Mikrochim Acta; 2018 Dec; 186(1):9. PubMed ID: 30535722
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A simple electrochemical approach to fabricate functionalized MWCNT-nanogold decorated PEDOT nanohybrid for simultaneous quantification of uric acid, xanthine and hypoxanthine.
    Sen S; Sarkar P
    Anal Chim Acta; 2020 Jun; 1114():15-28. PubMed ID: 32359511
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Simultaneous determination of uric acid, xanthine, hypoxanthine and caffeine in human blood serum and urine samples using electrochemically reduced graphene oxide modified electrode.
    Raj MA; John SA
    Anal Chim Acta; 2013 Apr; 771():14-20. PubMed ID: 23522107
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Gold nanoparticles decorated poly-melamine modified glassy carbon sensor for the voltammetric estimation of domperidone in pharmaceuticals and biological fluids.
    Rosy ; Goyal RN
    Talanta; 2015 Aug; 141():53-9. PubMed ID: 25966380
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Simultaneous and individual determination of seven biochemical species using a glassy carbon electrode modified with a nanocomposite of Pt nanoparticle and graphene by a one-step electrochemical process.
    Oh DE; Lee CS; Kim TH
    Talanta; 2022 Sep; 247():123590. PubMed ID: 35653858
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A glassy carbon electrode modified with a composite consisting of gold nanoparticle, reduced graphene oxide and poly(L-arginine) for simultaneous voltammetric determination of dopamine, serotonin and L-tryptophan.
    Khan MZH; Liu X; Tang Y; Zhu J; Hu W; Liu X
    Mikrochim Acta; 2018 Aug; 185(9):439. PubMed ID: 30167981
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Voltammetric determination of adenosine and guanosine using fullerene-C(60)-modified glassy carbon electrode.
    Goyal RN; Gupta VK; Oyama M; Bachheti N
    Talanta; 2007 Feb; 71(3):1110-7. PubMed ID: 19071420
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Synergic effect of silver nanoparticles and carbon nanotubes on the simultaneous voltammetric determination of hydroquinone, catechol, bisphenol A and phenol.
    Goulart LA; Gonçalves R; Correa AA; Pereira EC; Mascaro LH
    Mikrochim Acta; 2017 Dec; 185(1):12. PubMed ID: 29594601
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Simultaneous electrochemical determination of xanthine and uric acid at a nanoparticle film electrode.
    Sun Y; Fei J; Wu K; Hu S
    Anal Bioanal Chem; 2003 Feb; 375(4):544-9. PubMed ID: 12610708
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Gold nanoparticles embedded electropolymerized thin film of pyrimidine derivative on glassy carbon electrode for highly sensitive detection of l-cysteine.
    Kannan A; Sevvel R
    Mater Sci Eng C Mater Biol Appl; 2017 Sep; 78():513-519. PubMed ID: 28576016
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Glassy carbon electrodes modified with gold nanoparticles for the simultaneous determination of three food antioxidants.
    Lin X; Ni Y; Kokot S
    Anal Chim Acta; 2013 Feb; 765():54-62. PubMed ID: 23410626
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Gold nanoparticles plated porous silicon nanopowder for nonenzymatic voltammetric detection of hydrogen peroxide.
    Rashed MA; Harraz FA; Faisal M; El-Toni AM; Alsaiari M; Al-Assiri MS
    Anal Biochem; 2021 Feb; 615():114065. PubMed ID: 33321107
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Thiol functionalized carbon ceramic electrode modified with multi-walled carbon nanotubes and gold nanoparticles for simultaneous determination of purine derivatives.
    Ferrag C; Noroozifar M; Kerman K
    Mater Sci Eng C Mater Biol Appl; 2020 May; 110():110568. PubMed ID: 32204055
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Gold nanoparticle/multi-walled carbon nanotube modified glassy carbon electrode as a sensitive voltammetric sensor for the determination of diclofenac sodium.
    Afkhami A; Bahiraei A; Madrakian T
    Mater Sci Eng C Mater Biol Appl; 2016 Feb; 59():168-176. PubMed ID: 26652361
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.