These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

168 related articles for article (PubMed ID: 37276587)

  • 21. The origin of isomerization of aniline revealed by high kinetic energy ion mobility spectrometry (HiKE-IMS).
    Naylor CN; Schaefer C; Kirk AT; Zimmermann S
    Phys Chem Chem Phys; 2023 Jan; 25(2):1139-1152. PubMed ID: 36515135
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Pseudorandom sequence modifications for ion mobility orthogonal time-of-flight mass spectrometry.
    Clowers BH; Belov ME; Prior DC; Danielson WF; Ibrahim Y; Smith RD
    Anal Chem; 2008 Apr; 80(7):2464-73. PubMed ID: 18311942
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Field-Dependent Reduced Ion Mobilities of Positive and Negative Ions in Air and Nitrogen in High Kinetic Energy Ion Mobility Spectrometry (HiKE-IMS).
    Allers M; Kirk AT; Schaefer C; Erdogdu D; Wissdorf W; Benter T; Zimmermann S
    J Am Soc Mass Spectrom; 2020 Oct; 31(10):2191-2201. PubMed ID: 32865400
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Detecting and removing data artifacts in Hadamard transform ion mobility-mass spectrometry measurements.
    Prost SA; Crowell KL; Baker ES; Ibrahim YM; Clowers BH; Monroe ME; Anderson GA; Smith RD; Payne SH
    J Am Soc Mass Spectrom; 2014 Dec; 25(12):2020-2027. PubMed ID: 24796262
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Optimized Reconstruction Techniques for Multiplexed Dual-Gate Ion Mobility Mass Spectrometry Experiments.
    Davis AL; Reinecke T; Morrison KA; Clowers BH
    Anal Chem; 2019 Jan; 91(2):1432-1440. PubMed ID: 30561982
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Absorption Mode Fourier Transform Ion Mobility Mass Spectrometry Multiplexing Combined with Half-Window Apodization Windows Improves Resolution and Shortens Acquisition Times.
    Sanders JD; Butalewicz JP; Clowers BH; Brodbelt JS
    Anal Chem; 2021 Jul; 93(27):9513-9520. PubMed ID: 34185992
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Hadamard transform ion mobility spectrometry.
    Clowers BH; Siems WF; Hill HH; Massick SM
    Anal Chem; 2006 Jan; 78(1):44-51. PubMed ID: 16383309
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Ion Mobility Shift of Isotopologues in a High Kinetic Energy Ion Mobility Spectrometer (HiKE-IMS) at Elevated Effective Temperatures.
    Schaefer C; Kirk AT; Allers M; Zimmermann S
    J Am Soc Mass Spectrom; 2020 Oct; 31(10):2093-2101. PubMed ID: 32875796
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Influence of Reduced Field Strength on Product Ion Formation in High Kinetic Energy Ion Mobility Spectrometry (HiKE-IMS).
    Schaefer C; Allers M; Kirk AT; Schlottmann F; Zimmermann S
    J Am Soc Mass Spectrom; 2021 Jul; 32(7):1810-1820. PubMed ID: 34170133
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Improving Ion Mobility Mass Spectrometry of Proteins through Tristate Gating and Optimization of Multiplexing Parameters.
    Butalewicz JP; Sanders JD; Clowers BH; Brodbelt JS
    J Am Soc Mass Spectrom; 2023 Jan; 34(1):101-108. PubMed ID: 36469482
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Detection of Triacetone Triperoxide by High Kinetic Energy Ion Mobility Spectrometry.
    Schaefer C; Lippmann M; Beukers M; Beijer N; van de Kamp B; Knotter J; Zimmermann S
    Anal Chem; 2023 Nov; 95(46):17099-17107. PubMed ID: 37946366
    [TBL] [Abstract][Full Text] [Related]  

  • 32. High Kinetic Energy Ion Mobility Spectrometry (HiKE-IMS) at 40 mbar.
    Schlottmann F; Kirk AT; Allers M; Bohnhorst A; Zimmermann S
    J Am Soc Mass Spectrom; 2020 Jul; 31(7):1536-1543. PubMed ID: 32432872
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Masked Multiplexed Separations to Enhance Duty Cycle for Structures for Lossless Ion Manipulations.
    Clowers BH; Cabrera E; Anderson G; Deng L; Moser K; Van Aken G; DeBord JD
    Anal Chem; 2021 Apr; 93(14):5727-5734. PubMed ID: 33797223
    [TBL] [Abstract][Full Text] [Related]  

  • 34. High kinetic energy ion mobility spectrometer: quantitative analysis of gas mixtures with ion mobility spectrometry.
    Langejuergen J; Allers M; Oermann J; Kirk A; Zimmermann S
    Anal Chem; 2014 Jul; 86(14):7023-32. PubMed ID: 24937741
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Synchronized Stepped Frequency Modulation for Multiplexed Ion Mobility Measurements.
    Cabrera ER; Clowers BH
    J Am Soc Mass Spectrom; 2022 Mar; 33(3):557-564. PubMed ID: 35108007
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Development of an ion mobility spectrometer for use in an atmospheric pressure ionization ion mobility spectrometer/mass spectrometer instrument for fast screening analysis.
    Sysoev A; Adamov A; Viidanoja J; Ketola RA; Kostiainen R; Kotiaho T
    Rapid Commun Mass Spectrom; 2004; 18(24):3131-9. PubMed ID: 15565719
    [TBL] [Abstract][Full Text] [Related]  

  • 37. High Resolving Power Electrospray Ionization Ion Mobility Spectrometer Based on Fourier Deconvolution Multiplexing.
    Yang B; Ye Z; Lu F; Yu J; Liu J; Zheng X; Wang C; Duan L; Yang Z; Jing G; Liu W; Li W; Liu W
    Anal Chem; 2024 Oct; 96(43):17423-17431. PubMed ID: 39413295
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Using Hadamard Transform Multiplexed IR Spectroscopy Together with a Segmented Ion Trap for the Identification of Mobility-Selected Isomers.
    Yatsyna V; Abikhodr AH; Ben Faleh A; Warnke S; Rizzo TR
    Anal Chem; 2023 Jun; 95(25):9623-9629. PubMed ID: 37307499
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Influence of Sample Gas Humidity on Product Ion Formation in High Kinetic Energy Ion Mobility Spectrometry (HiKE-IMS).
    Schaefer C; Schlottmann F; Kirk AT; Zimmermann S
    J Am Soc Mass Spectrom; 2022 Jun; 33(6):1048-1060. PubMed ID: 35594571
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A Simple Analytical Model for Predicting the Detectable Ion Current in Ion Mobility Spectrometry Using Corona Discharge Ionization Sources.
    Kirk AT; Kobelt T; Spehlbrink H; Zimmermann S
    J Am Soc Mass Spectrom; 2018 Jul; 29(7):1425-1430. PubMed ID: 29740761
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.