144 related articles for article (PubMed ID: 37287315)
1. A novel calorimeter for synchrotron produced monochromatic x-ray beams.
El Gamal I; Dessureault J; McEwen MR
Med Phys; 2023 Oct; 50(10):6543-6553. PubMed ID: 37287315
[TBL] [Abstract][Full Text] [Related]
2. Absolute x-ray dosimetry on a synchrotron medical beam line with a graphite calorimeter.
Harty PD; Lye JE; Ramanathan G; Butler DJ; Hall CJ; Stevenson AW; Johnston PN
Med Phys; 2014 May; 41(5):052101. PubMed ID: 24784390
[TBL] [Abstract][Full Text] [Related]
3. Monte Carlo and
Lawless MJ; Dimaso L; Palmer B; Micka J; Culberson WS; DeWerd LA
Med Phys; 2018 Dec; 45(12):5564-5576. PubMed ID: 30273996
[TBL] [Abstract][Full Text] [Related]
4. Verification of TG-61 dose for synchrotron-produced monochromatic x-ray beams using fluence-normalized MCNP5 calculations.
Brown TA; Hogstrom KR; Alvarez D; Matthews KL; Ham K
Med Phys; 2012 Dec; 39(12):7462-9. PubMed ID: 23231295
[TBL] [Abstract][Full Text] [Related]
5. A graphite calorimeter for absolute measurements of absorbed dose to water: application in medium-energy x-ray filtered beams.
Pinto M; Pimpinella M; Quini M; D'Arienzo M; Astefanoaei I; Loreti S; Guerra AS
Phys Med Biol; 2016 Feb; 61(4):1738-64. PubMed ID: 26841127
[TBL] [Abstract][Full Text] [Related]
6. Alanine response to low energy synchrotron x-ray radiation.
van den Elzen P; Sander T; Palmans H; McManus M; Woodall N; Lee N; Fox OJL; Jones RM; Angal-Kalinin D; Subiel A
Phys Med Biol; 2023 Mar; 68(6):. PubMed ID: 36731142
[No Abstract] [Full Text] [Related]
7. Response of LiF:Mg,Ti thermoluminescent dosimeters at photon energies relevant to the dosimetry of brachytherapy (<1 MeV).
Tedgren AC; Hedman A; Grindborg JE; Carlsson GA
Med Phys; 2011 Oct; 38(10):5539-50. PubMed ID: 21992372
[TBL] [Abstract][Full Text] [Related]
8. Absolute dosimetry on a dynamically scanned sample for synchrotron radiotherapy using graphite calorimetry and ionization chambers.
Lye JE; Harty PD; Butler DJ; Crosbie JC; Livingstone J; Poole CM; Ramanathan G; Wright T; Stevenson AW
Phys Med Biol; 2016 Jun; 61(11):4201-22. PubMed ID: 27192396
[TBL] [Abstract][Full Text] [Related]
9. Dose profiles and x-ray energy optimization for microbeam radiation therapy by high-dose, high resolution dosimetry using Sm-doped fluoroaluminate glass plates and Monte Carlo transport simulation.
Chicilo F; Hanson AL; Geisler FH; Belev G; Edgar A; Ramaswami KO; Chapman D; Kasap SO
Phys Med Biol; 2020 Apr; 65(7):075010. PubMed ID: 32242527
[TBL] [Abstract][Full Text] [Related]
10. Treatment plans optimization for contrast-enhanced synchrotron stereotactic radiotherapy.
Edouard M; Broggio D; Prezado Y; Estève F; Elleaume H; Adam JF
Med Phys; 2010 Jun; 37(6):2445-56. PubMed ID: 20632555
[TBL] [Abstract][Full Text] [Related]
11. Investigation of a synthetic diamond detector response in kilovoltage photon beams.
Kaveckyte V; Persson L; Malusek A; Benmakhlouf H; Alm Carlsson G; Carlsson Tedgren Å
Med Phys; 2020 Mar; 47(3):1268-1279. PubMed ID: 31880809
[TBL] [Abstract][Full Text] [Related]
12. Characterization of a synthetic single crystal diamond detector for dosimetry in spatially fractionated synchrotron x-ray fields.
Livingstone J; Stevenson AW; Butler DJ; Häusermann D; Adam JF
Med Phys; 2016 Jul; 43(7):4283. PubMed ID: 27370143
[TBL] [Abstract][Full Text] [Related]
13. Absorbed dose determination in kilovoltage X-ray synchrotron radiation using alanine dosimeters.
Butler DJ; Lye JE; Wright TE; Crossley D; Sharpe PH; Stevenson AW; Livingstone J; Crosbie JC
Australas Phys Eng Sci Med; 2016 Dec; 39(4):943-950. PubMed ID: 27585452
[TBL] [Abstract][Full Text] [Related]
14. Synchrotron stereotactic radiotherapy: dosimetry by Fricke gel and Monte Carlo simulations.
Boudou C; Biston MC; Corde S; Adam JF; Ferrero C; Estève F; Elleaume H
Phys Med Biol; 2004 Nov; 49(22):5135-44. PubMed ID: 15609563
[TBL] [Abstract][Full Text] [Related]
15. The PTB water calorimeter for determining the absolute absorbed dose to water in ultra-high pulse dose rate electron beams.
Bourgouin A; Hackel T; Kapsch RP
Phys Med Biol; 2023 May; 68(11):. PubMed ID: 37072007
[No Abstract] [Full Text] [Related]
16. Dose-response curve of EBT, EBT2, and EBT3 radiochromic films to synchrotron-produced monochromatic x-ray beams.
Brown TA; Hogstrom KR; Alvarez D; Matthews KL; Ham K; Dugas JP
Med Phys; 2012 Dec; 39(12):7412-7. PubMed ID: 23231291
[TBL] [Abstract][Full Text] [Related]
17. Water equivalent PRESAGE
Gagliardi FM; Day L; Poole CM; Franich RD; Geso M
Med Phys; 2018 Mar; 45(3):1255-1265. PubMed ID: 29314051
[TBL] [Abstract][Full Text] [Related]
18. Technical note: Influence of the phantom material on the absorbed-dose energy dependence of the EBT3 radiochromic film for photons in the energy range 3 keV-18 MeV.
Hermida-López M; Lüdemann L; Flühs A; Brualla L
Med Phys; 2014 Nov; 41(11):112103. PubMed ID: 25370654
[TBL] [Abstract][Full Text] [Related]
19. Dosimetry protocol for the forthcoming clinical trials in synchrotron stereotactic radiation therapy (SSRT).
Prezado Y; Vautrin M; Martínez-Rovira I; Bravin A; Estève F; Elleaume H; Berkvens P; Adam JF
Med Phys; 2011 Mar; 38(3):1709-17. PubMed ID: 21520884
[TBL] [Abstract][Full Text] [Related]
20. Response of lithium formate EPR dosimeters at photon energies relevant to the dosimetry of brachytherapy.
Adolfsson E; Carlsson GA; Grindborg JE; Gustafsson H; Lund E; Carlsson Tedgren A
Med Phys; 2010 Sep; 37(9):4946-59. PubMed ID: 20964214
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]