These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

127 related articles for article (PubMed ID: 3729022)

  • 21. The effects of airway impedance on work of breathing during halothane anesthesia.
    Slee TA; Sharar SR; Pavlin EG; MacIntyre PE
    Anesth Analg; 1989 Sep; 69(3):374-8. PubMed ID: 2774234
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Does the tube-compensation function of two modern mechanical ventilators provide effective work of breathing relief?
    Maeda Y; Fujino Y; Uchiyama A; Taenaka N; Mashimo T; Nishimura M
    Crit Care; 2003 Oct; 7(5):R92-7. PubMed ID: 12974975
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Accuracy of automatic tube compensation in new-generation mechanical ventilators.
    Elsasser S; Guttmann J; Stocker R; Mols G; Priebe HJ; Haberthür C
    Crit Care Med; 2003 Nov; 31(11):2619-26. PubMed ID: 14605533
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Automatic tube compensation (ATC).
    Guttmann J; Haberthür C; Mols G; Lichtwarck-Aschoff M
    Minerva Anestesiol; 2002 May; 68(5):369-77. PubMed ID: 12029248
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Effect of inner cannula removal on the work of breathing imposed by tracheostomy tubes: a bench study.
    Cowan T; Op't Holt TB; Gegenheimer C; Izenberg S; Kulkarni P
    Respir Care; 2001 May; 46(5):460-5. PubMed ID: 11309185
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Measurement of respiratory impedance by impulse oscillometry--effects of endotracheal tubes.
    Kuhnle GE; Brandt T; Roth U; Goetz AE; Smith HJ; Peter K
    Res Exp Med (Berl); 2000 Dec; 200(1):17-26. PubMed ID: 11197918
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Impact of endotracheal tube shortening on work of breathing in neonatal and pediatric in vitro lung models.
    Mohr R; Thomas J; Cannizzaro V; Weiss M; Schmidt AR
    Paediatr Anaesth; 2017 Sep; 27(9):942-948. PubMed ID: 28653420
    [TBL] [Abstract][Full Text] [Related]  

  • 28. In vitro versus in vivo comparison of endotracheal tube airflow resistance.
    Wright PE; Marini JJ; Bernard GR
    Am Rev Respir Dis; 1989 Jul; 140(1):10-6. PubMed ID: 2751156
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Effects of helium-oxygen mixtures on endotracheal tubes: an in vitro study.
    Gerbeaux P; Gainnier M; Arnal JM; Papazian L; Jean P; Sainty JM
    J Biomech; 2005 Jan; 38(1):33-7. PubMed ID: 15519337
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Different tracheotomy tube diameters influence diaphragmatic effort and indices of weanability in difficult to wean patients.
    Valentini I; Tonveronachi E; Gregoretti C; Mega C; Fasano L; Pisani L; Nava S
    Respir Care; 2012 Dec; 57(12):2012-8. PubMed ID: 22612986
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Flow-volume relationships during spontaneous breathing through endotracheal tubes.
    Weissman C
    Crit Care Med; 1992 May; 20(5):615-20. PubMed ID: 1572186
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Physiologic impact of closed-system endotracheal suctioning in spontaneously breathing patients receiving mechanical ventilation.
    Seymour CW; Cross BJ; Cooke CR; Gallop RL; Fuchs BD
    Respir Care; 2009 Mar; 54(3):367-74. PubMed ID: 19245731
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The esophageal-tracheal combitube resistance and ventilatory pressures.
    Gaitini LA; Vaida SJ; Mostafa S; Yanovski B; Ben-David B; Benumof JL
    J Clin Anesth; 2005 Feb; 17(1):26-9. PubMed ID: 15721726
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Work of breathing through different sized endotracheal tubes.
    Shapiro M; Wilson RK; Casar G; Bloom K; Teague RB
    Crit Care Med; 1986 Dec; 14(12):1028-31. PubMed ID: 3780244
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Flow resistance of endotracheal tubes during kinking and compression. An experimental study.
    Nilsson K; Stenqvist O
    Med Prog Technol; 1985; 10(4):249-54. PubMed ID: 4033599
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Spontaneous Breathing and Imposed Work During Pediatric Mechanical Ventilation: A Bench Study.
    van Dijk J; Blokpoel RGT; Koopman AA; Brandsema R; Newth CJL; Kneyber MCJ
    Pediatr Crit Care Med; 2020 Jul; 21(7):e449-e455. PubMed ID: 32427436
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Evaluation of a new thin-walled endotracheal tube for use in children.
    Okhuysen RS; Bristow F; Burkhead S; Kolobow T; Lally KP
    Chest; 1996 May; 109(5):1335-8. PubMed ID: 8625687
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Measurement of pulsatile tidal volume, pressure amplitude, and gas flow during high-frequency percussive ventilation, with and without partial cuff deflation.
    Allan PF; Thurlby JR; Naworol GA
    Respir Care; 2007 Jan; 52(1):45-9. PubMed ID: 17194317
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Additional work of breathing imposed by endotracheal tubes, breathing circuits, and intensive care ventilators.
    Bersten AD; Rutten AJ; Vedig AE; Skowronski GA
    Crit Care Med; 1989 Jul; 17(7):671-7. PubMed ID: 2736929
    [TBL] [Abstract][Full Text] [Related]  

  • 40. The effect of inner tube placement on resistance and work of breathing through tracheostomy tubes: a bench test.
    Carter A; Fletcher SJ; Tuffin R
    Anaesthesia; 2013 Mar; 68(3):276-82. PubMed ID: 23278349
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.