These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 37292463)

  • 1. Needle guidance with Doppler-tracked polarization-sensitive optical coherence tomography.
    Harper DJ; Kim Y; Gómez-Ramírez A; Vakoc BJ
    ArXiv; 2023 May; ():. PubMed ID: 37292463
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Needle guidance with Doppler-tracked polarization-sensitive optical coherence tomography.
    Harper DJ; Kim Y; Gómez-Ramírez A; Vakoc BJ
    J Biomed Opt; 2023 Oct; 28(10):102910. PubMed ID: 37799938
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Enhancing epidural needle guidance using a polarization-sensitive optical coherence tomography probe with convolutional neural networks.
    Wang C; Liu Y; Calle P; Li X; Liu R; Zhang Q; Yan F; Fung KM; Conner AK; Chen S; Pan C; Tang Q
    J Biophotonics; 2024 Feb; 17(2):e202300330. PubMed ID: 37833242
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In Vivo 3D Determination of Peripapillary Scleral and Retinal Layer Architecture Using Polarization-Sensitive Optical Coherence Tomography.
    Willemse J; Gräfe MGO; Verbraak FD; de Boer JF
    Transl Vis Sci Technol; 2020 Oct; 9(11):21. PubMed ID: 33150047
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Fiber-based polarization-sensitive OCT of the human retina with correction of system polarization distortions.
    Braaf B; Vermeer KA; de Groot M; Vienola KV; de Boer JF
    Biomed Opt Express; 2014 Aug; 5(8):2736-58. PubMed ID: 25136498
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Endoscopic imaging of white matter fiber tracts using polarization-sensitive optical coherence tomography.
    DePaoli D; Côté DC; Bouma BE; Villiger M
    Neuroimage; 2022 Dec; 264():119755. PubMed ID: 36400379
    [TBL] [Abstract][Full Text] [Related]  

  • 7. In vivo imaging of human oral hard and soft tissues by polarization-sensitive optical coherence tomography.
    Walther J; Golde J; Kirsten L; Tetschke F; Hempel F; Rosenauer T; Hannig C; Koch E
    J Biomed Opt; 2017 Dec; 22(12):1-17. PubMed ID: 29264891
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Fiber-Needle Swept-Source Optical Coherence Tomography for the Real-Time Visualization of the Transversus Abdominis Plane Block Procedure in a Swine Model.
    Teng WN; Kao MC; Ting CK; Kuo WC
    Anesth Analg; 2021 Aug; 133(2):526-534. PubMed ID: 33264115
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Henle fiber layer phase retardation measured with polarization-sensitive optical coherence tomography.
    Cense B; Wang Q; Lee S; Zhao L; Elsner AE; Hitzenberger CK; Miller DT
    Biomed Opt Express; 2013; 4(11):2296-306. PubMed ID: 24298395
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Polarization state tracing method to map local birefringent properties in samples using polarization sensitive optical coherence tomography.
    Tang P; Wang RK
    Biomed Opt Express; 2020 Dec; 11(12):6852-6863. PubMed ID: 33408966
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fiber-needle swept-source optical coherence tomography system for the identification of the epidural space in piglets.
    Kuo WC; Kao MC; Chang KY; Teng WN; Tsou MY; Chang Y; Ting CK
    Anesthesiology; 2015 Mar; 122(3):585-94. PubMed ID: 25437497
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Real-time epidural anesthesia guidance using optical coherence tomography needle probe.
    Tang Q; Liang CP; Wu K; Sandler A; Chen Y
    Quant Imaging Med Surg; 2015 Feb; 5(1):118-24. PubMed ID: 25694961
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Polarization maintaining fiber based ultra-high resolution spectral domain polarization sensitive optical coherence tomography.
    Götzinger E; Baumann B; Pircher M; Hitzenberger CK
    Opt Express; 2009 Dec; 17(25):22704-17. PubMed ID: 20052196
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Digital calibration method to enable depth-resolved all-fiber polarization sensitive optical coherence tomography with an arbitrary input polarization state.
    Tang P; Wang RK; Chao Q
    Biomed Opt Express; 2024 May; 15(5):3329-3343. PubMed ID: 38855689
    [TBL] [Abstract][Full Text] [Related]  

  • 15. High-speed polarization sensitive optical coherence tomography scan engine based on Fourier domain mode locked laser.
    Bonesi M; Sattmann H; Torzicky T; Zotter S; Baumann B; Pircher M; Götzinger E; Eigenwillig C; Wieser W; Huber R; Hitzenberger CK
    Biomed Opt Express; 2012 Nov; 3(11):2987-3000. PubMed ID: 23162734
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Epidural anesthesia needle guidance by forward-view endoscopic optical coherence tomography and deep learning.
    Wang C; Calle P; Reynolds JC; Ton S; Yan F; Donaldson AM; Ladymon AD; Roberts PR; de Armendi AJ; Fung KM; Shettar SS; Pan C; Tang Q
    Sci Rep; 2022 May; 12(1):9057. PubMed ID: 35641505
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Robust reconstruction of local optic axis orientation with fiber-based polarization-sensitive optical coherence tomography.
    Li Q; Karnowski K; Noble PB; Cairncross A; James A; Villiger M; Sampson DD
    Biomed Opt Express; 2018 Nov; 9(11):5437-5455. PubMed ID: 30460138
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Determination of characteristics of degenerative joint disease using optical coherence tomography and polarization sensitive optical coherence tomography.
    Xie T; Guo S; Zhang J; Chen Z; Peavy GM
    Lasers Surg Med; 2006 Oct; 38(9):852-65. PubMed ID: 16998913
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Determination of birefringence and absolute optic axis orientation using polarization-sensitive optical coherence tomography with PM fibers.
    Zhang J; Guo S; Jung W; Nelson J; Chen Z
    Opt Express; 2003 Dec; 11(24):3262-70. PubMed ID: 19471453
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Polarization-sensitive spectral-domain optical coherence tomography using a single line scan camera.
    Cense B; Mujat M; Chen TC; Park BH; de Boer JF
    Opt Express; 2007 Mar; 15(5):2421-31. PubMed ID: 19532479
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.