123 related articles for article (PubMed ID: 37295618)
1. Traffic Cameras-An Effective and Sustainable Method of Reducing Traffic and Airborne Particles During Arthroplasty Surgery. Nooh A; Tanzer M; Alzeedi M; Lavoie-Turcotte T; Hart A J Arthroplasty; 2024 Jan; 39(1):255-260. PubMed ID: 37295618 [TBL] [Abstract][Full Text] [Related]
2. Operating Room Traffic Increases Aerosolized Particles and Compromises the Air Quality: A Simulated Study. Rezapoor M; Alvand A; Jacek E; Paziuk T; Maltenfort MG; Parvizi J J Arthroplasty; 2018 Mar; 33(3):851-855. PubMed ID: 29174409 [TBL] [Abstract][Full Text] [Related]
3. Door Opening Affects Operating Room Pressure During Joint Arthroplasty. Mears SC; Blanding R; Belkoff SM Orthopedics; 2015 Nov; 38(11):e991-4. PubMed ID: 26558679 [TBL] [Abstract][Full Text] [Related]
4. The Effect of a Door Alarm on Operating Room Traffic During Total Joint Arthroplasty. Eskildsen SM; Moskal PT; Laux J; Del Gaizo DJ Orthopedics; 2017 Nov; 40(6):e1081-e1085. PubMed ID: 29116327 [TBL] [Abstract][Full Text] [Related]
5. Operating room traffic in total joint arthroplasty: Identifying patterns and training the team to keep the door shut. Hamilton WG; Balkam CB; Purcell RL; Parks NL; Holdsworth JE Am J Infect Control; 2018 Jun; 46(6):633-636. PubMed ID: 29455920 [TBL] [Abstract][Full Text] [Related]
6. Traffic in the operating room during joint replacement is a multidisciplinary problem. Bédard M; Pelletier-Roy R; Angers-Goulet M; Leblanc PA; Pelet S Can J Surg; 2015 Aug; 58(4):232-6. PubMed ID: 26022153 [TBL] [Abstract][Full Text] [Related]
7. High Number of Door Openings Increases the Bacterial Load of the Operating Room. Lansing SS; Moley JP; McGrath MS; Stoodley P; Chaudhari AMW; Quatman CE Surg Infect (Larchmt); 2021 Sep; 22(7):684-689. PubMed ID: 33370210 [No Abstract] [Full Text] [Related]
8. Assessment of operating room airflow using air particle counts and direct observation of door openings. Teter J; Guajardo I; Al-Rammah T; Rosson G; Perl TM; Manahan M Am J Infect Control; 2017 May; 45(5):477-482. PubMed ID: 28209451 [TBL] [Abstract][Full Text] [Related]
9. Operating room traffic is a major concern during total joint arthroplasty. Panahi P; Stroh M; Casper DS; Parvizi J; Austin MS Clin Orthop Relat Res; 2012 Oct; 470(10):2690-4. PubMed ID: 22302655 [TBL] [Abstract][Full Text] [Related]
10. The Effect of Door Opening on Positive Pressure and Airflow in Operating Rooms. Weiser MC; Shemesh S; Chen DD; Bronson MJ; Moucha CS J Am Acad Orthop Surg; 2018 Mar; 26(5):e105-e113. PubMed ID: 29419726 [TBL] [Abstract][Full Text] [Related]
11. Operating Room Traffic in Total Joint Arthroplasty: One Simple Measure Toward Solving a Complex Problem. Osborn NS; Hoehmann CL; McCormack R; Owens J JB JS Open Access; 2020; 5(3):. PubMed ID: 32803103 [TBL] [Abstract][Full Text] [Related]
12. Traffic flow and microbial air contamination in operating rooms at a major teaching hospital in Ghana. Stauning MT; Bediako-Bowan A; Andersen LP; Opintan JA; Labi AK; Kurtzhals JAL; Bjerrum S J Hosp Infect; 2018 Jul; 99(3):263-270. PubMed ID: 29253624 [TBL] [Abstract][Full Text] [Related]
13. Room Traffic in Orthopedic Surgery: A Prospective Clinical Observational Study of Time of Day. Patel PG; DiBartola AC; Phieffer LS; Scharschmidt TJ; Mayerson JL; Glassman AH; Moffatt-Bruce SD; Quatman CE J Patient Saf; 2021 Apr; 17(3):e241-e246. PubMed ID: 29112032 [TBL] [Abstract][Full Text] [Related]
14. Effects of Intervention and Team Culture on Operating Room Traffic. Pulido RW; Kester B; Schwarzkopf R Qual Manag Health Care; 2017; 26(2):103-107. PubMed ID: 28375957 [TBL] [Abstract][Full Text] [Related]
15. The Effect of Door Openings on Numbers of Colony Forming Units in the Operating Room during Hip Revision Surgery. Mathijssen NM; Hannink G; Sturm PD; Pilot P; Bloem RM; Buma P; Petit PL; Schreurs BW Surg Infect (Larchmt); 2016 Oct; 17(5):535-40. PubMed ID: 27206050 [TBL] [Abstract][Full Text] [Related]
16. Motion-capture system to assess intraoperative staff movements and door openings: Impact on surrogates of the infectious risk in surgery. Birgand G; Azevedo C; Rukly S; Pissard-Gibollet R; Toupet G; Timsit JF; Lucet JC; Infect Control Hosp Epidemiol; 2019 May; 40(5):566-573. PubMed ID: 30857569 [TBL] [Abstract][Full Text] [Related]
17. The Effect of an Interdisciplinary QI Project to Reduce OR Foot Traffic. Rovaldi CJ; King PJ AORN J; 2015 Jun; 101(6):666-78; quiz 679-81. PubMed ID: 26025743 [TBL] [Abstract][Full Text] [Related]
18. Reduction of Particles in the Operating Room Using Ultraviolet Air Disinfection and Recirculation Units. Curtis GL; Faour M; Jawad M; Klika AK; Barsoum WK; Higuera CA J Arthroplasty; 2018 Jul; 33(7S):S196-S200. PubMed ID: 29273292 [TBL] [Abstract][Full Text] [Related]
19. Does a sign restricting operating room access reduce staff traffic in the surgical department? Erivan R; Villatte G; Haverlan A; Roullet CA; Ouchchane L; Descamps S; Boisgard S Orthop Traumatol Surg Res; 2024 Sep; 110(5):103843. PubMed ID: 38387645 [TBL] [Abstract][Full Text] [Related]
20. Door openings in the operating room are associated with increased environmental contamination. Perez P; Holloway J; Ehrenfeld L; Cohen S; Cunningham L; Miley GB; Hollenbeck BL Am J Infect Control; 2018 Aug; 46(8):954-956. PubMed ID: 29735254 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]