BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

499 related articles for article (PubMed ID: 37299010)

  • 1. Methods to Detect Volatile Organic Compounds for Breath Biopsy Using Solid-Phase Microextraction and Gas Chromatography-Mass Spectrometry.
    Schulz E; Woollam M; Grocki P; Davis MD; Agarwal M
    Molecules; 2023 Jun; 28(11):. PubMed ID: 37299010
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Quantifying exhaled acetone and isoprene through solid phase microextraction and gas chromatography-mass spectrometry.
    Schulz E; Woollam M; Vashistha S; Agarwal M
    Anal Chim Acta; 2024 May; 1301():342468. PubMed ID: 38553125
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluating polyvinylidene fluoride - carbon black composites as solid phase microextraction coatings for the detection of urinary volatile organic compounds by gas chromatography-mass spectrometry.
    Woollam M; Grocki P; Schulz E; Siegel AP; Deiss F; Agarwal M
    J Chromatogr A; 2022 Dec; 1685():463606. PubMed ID: 36370629
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Exhaled VOCs can discriminate subjects with COVID-19 from healthy controls.
    Woollam M; Angarita-Rivera P; Siegel AP; Kalra V; Kapoor R; Agarwal M
    J Breath Res; 2022 May; 16(3):. PubMed ID: 35453137
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Breath analysis of smokers, non-smokers, and e-cigarette users.
    Papaefstathiou E; Stylianou M; Andreou C; Agapiou A
    J Chromatogr B Analyt Technol Biomed Life Sci; 2020 Dec; 1160():122349. PubMed ID: 32920481
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Exploratory study on noninvasive biomarker of silicosis in exhaled breath by solid-phase microextraction-gas chromatography-mass spectrometry analysis.
    Yi Z; Dong S; Wang X; Xu M; Li Y; Xie L
    Int Arch Occup Environ Health; 2023 Aug; 96(6):857-868. PubMed ID: 37067574
    [TBL] [Abstract][Full Text] [Related]  

  • 7. IMPACT OF BREATH SAMPLE COLLECTION METHOD AND LENGTH OF STORAGE OF BREATH SAMPLES IN TEDLAR BAGS ON THE LEVEL OF SELECTED VOLATILES ASSESSED USING GAS CHROMATOGRAPHY-ION MOBILITY SPECTROMETRY (GC-IMS).
    Czippelova B; Novakova S; Sarlinova M; Baranovicova E; Urbanova A; Turianikova Z; Cernanova Krohova J; Halasova E; Skovierova H
    J Breath Res; 2024 May; ():. PubMed ID: 38701772
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Stability of selected volatile breath constituents in Tedlar, Kynar and Flexfilm sampling bags.
    Mochalski P; King J; Unterkofler K; Amann A
    Analyst; 2013 Mar; 138(5):1405-18. PubMed ID: 23323261
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Determination of acetone in human breath by gas chromatography-mass spectrometry and solid-phase microextraction with on-fiber derivatization.
    Deng C; Zhang J; Yu X; Zhang W; Zhang X
    J Chromatogr B Analyt Technol Biomed Life Sci; 2004 Oct; 810(2):269-75. PubMed ID: 15380724
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A multiple-method comparative study using GC-MS, AMDIS and in-house-built software for the detection and identification of "unknown" volatile organic compounds in breath.
    Marder D; Tzanani N; Baratz A; Drug E; Prihed H; Weiss S; Ben-Chetrit E; Eichel R; Dagan S; Yishai Aviram L
    J Mass Spectrom; 2021 Oct; 56(10):e4782. PubMed ID: 34523187
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Noninvasive detection of lung cancer by analysis of exhaled breath.
    Bajtarevic A; Ager C; Pienz M; Klieber M; Schwarz K; Ligor M; Ligor T; Filipiak W; Denz H; Fiegl M; Hilbe W; Weiss W; Lukas P; Jamnig H; Hackl M; Haidenberger A; Buszewski B; Miekisch W; Schubert J; Amann A
    BMC Cancer; 2009 Sep; 9():348. PubMed ID: 19788722
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Glass bottle sampling solid phase microextraction gas chromatography mass spectrometry for breath analysis of drug metabolites.
    Lu Y; Niu W; Zou X; Shen C; Xia L; Huang C; Wang H; Jiang H; Chu Y
    J Chromatogr A; 2017 May; 1496():20-24. PubMed ID: 28365077
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Optimization and validation of headspace solid-phase microextraction method coupled with gas chromatography-triple quadrupole tandem mass spectrometry for simultaneous determination of volatile and semi-volatile organic compounds in coking wastewater treatment plant.
    Saber AN; Zhang H; Yang M
    Environ Monit Assess; 2019 Jun; 191(7):411. PubMed ID: 31165936
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Relationship between cancer tissue derived and exhaled volatile organic compound from colorectal cancer patients. Preliminary results.
    De Vietro N; Aresta A; Rotelli MT; Zambonin C; Lippolis C; Picciariello A; Altomare DF
    J Pharm Biomed Anal; 2020 Feb; 180():113055. PubMed ID: 31877489
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Detection technologies of volatile organic compounds in the breath for cancer diagnoses.
    Le T; Priefer R
    Talanta; 2023 Dec; 265():124767. PubMed ID: 37327663
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Phase-resolved real-time breath analysis during exercise by means of smart processing of PTR-MS data.
    Schwoebel H; Schubert R; Sklorz M; Kischkel S; Zimmermann R; Schubert JK; Miekisch W
    Anal Bioanal Chem; 2011 Oct; 401(7):2079-91. PubMed ID: 21706328
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Analysis of volatile organic compounds and potential odour compounds in food contact paperboard using headspace two-dimensional GC-QTOF-MS.
    Li D; Zeng Y; Ye ZK; Li HK; Li YZ; Dong B; Su QZ; Lin QB; Xiao J; Zhong HN
    Food Addit Contam Part A Chem Anal Control Expo Risk Assess; 2023 Nov; 40(11):1482-1493. PubMed ID: 37831931
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Profiling allergic asthma volatile metabolic patterns using a headspace-solid phase microextraction/gas chromatography based methodology.
    Caldeira M; Barros AS; Bilelo MJ; Parada A; Câmara JS; Rocha SM
    J Chromatogr A; 2011 Jun; 1218(24):3771-80. PubMed ID: 21546028
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Chromatographic analysis of VOC patterns in exhaled breath from smokers and nonsmokers.
    Capone S; Tufariello M; Forleo A; Longo V; Giampetruzzi L; Radogna AV; Casino F; Siciliano P
    Biomed Chromatogr; 2018 Apr; 32(4):. PubMed ID: 29131420
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Novel extraction of volatile biomarkers from canine breath for gas chromatography-mass spectrometry.
    Dissanayake S; Lathan P; Mlsna T
    J Breath Res; 2012 Dec; 6(4):041001. PubMed ID: 22989995
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 25.