These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

86 related articles for article (PubMed ID: 3730162)

  • 1. Polycarbonate-polyether (PC-PE) flat sheet membrane: manufacture, structure and performance.
    Konstantin P; Bailey RM
    Blood Purif; 1986; 4(1-3):6-12. PubMed ID: 3730162
    [TBL] [Abstract][Full Text] [Related]  

  • 2. PC-PE hollow-fiber membrane. Structure, performance characteristics and manufacturing.
    Göhl H; Raff M; Harttig H; Deppisch R
    Blood Purif; 1986; 4(1-3):23-31. PubMed ID: 3730157
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Clinical evaluation of a flat plate dialyzer equipped with a polycarbonate polyether copolymer membrane.
    Jacobs C; Sari R
    Blood Purif; 1986; 4(1-3):32-9. PubMed ID: 3730158
    [TBL] [Abstract][Full Text] [Related]  

  • 4. New polymer alloy dialysis membranes with varying permeabilities and sievings.
    Shimizu M; Kanamori T; Sakai K; Igoshi T; Yoshida M
    ASAIO J; 1992; 38(4):784-7. PubMed ID: 1280488
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Calculation of combined diffusive and convective mass transfer.
    Sigdell JE
    Int J Artif Organs; 1982 Nov; 5(6):361-72. PubMed ID: 7160932
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Clinical use of NISR 440 polycarbonate membrane for hemodialysis.
    Barbour BH; Bernstein M; Cantor PA; Fisher BS; Stone W
    Trans Am Soc Artif Intern Organs; 1975; 21():144-55. PubMed ID: 1145988
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Diffusion and calibration properties of microdialysis sampling membranes in biological media.
    Snyder KL; Nathan CE; Yee A; Stenken JA
    Analyst; 2001 Aug; 126(8):1261-8. PubMed ID: 11534590
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Mass transfer characterization of a new polysulfone membrane.
    Schneider H; Streicher E
    Artif Organs; 1985 May; 9(2):180-3. PubMed ID: 4015455
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Removal of beta-2-microglobulin by diffusion alone is feasible using highly permeable dialysis membranes.
    Naitoh A; Tatsuguchi T; Okada M; Ohmura T; Sakai K
    ASAIO Trans; 1988; 34(3):630-4. PubMed ID: 3058183
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of new membranes for hemodialysis: preliminary studies with a polycarbonate membrane.
    Bianchi R; Bionda A; Carmassi F; Palla R; Donadio C; Galli M; Chiellini E; Molea N; Mariani G
    J Dial; 1979; 3(4):383-93. PubMed ID: 263960
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The development of a polysulfone membrane. A new perspective in dialysis?
    Streicher E; Schneider H
    Contrib Nephrol; 1985; 46():1-13. PubMed ID: 4006470
    [No Abstract]   [Full Text] [Related]  

  • 12. Diffusive and convective solute transport through hemodialysis membranes: a hydrodynamic analysis.
    Langsdorf LJ; Zydney AL
    J Biomed Mater Res; 1994 May; 28(5):573-82. PubMed ID: 7517941
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Biocompatibility aspects of cellophane, cellulose acetate, polyacrylonitrile, polysulfone and polycarbonate hemodialyzers.
    Smeby LC; Widerøe TE; Balstad T; Jørstad S
    Blood Purif; 1986; 4(1-3):93-101. PubMed ID: 3730167
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The biocompatibility and separation performance of antioxidative polysulfone/vitamin E TPGS composite hollow fiber membranes.
    Dahe GJ; Teotia RS; Kadam SS; Bellare JR
    Biomaterials; 2011 Jan; 32(2):352-65. PubMed ID: 20888631
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effect of protein adsorption on the transport characteristics of asymmetric ultrafiltration membranes.
    Mochizuki S; Zydney AL
    Biotechnol Prog; 1992; 8(6):553-61. PubMed ID: 1369038
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Technical and clinical evaluation of a new asymmetric polysulfone membrane (Biosulfane).
    Ronco C; Brendolan A; Crepaldi C; Bettini MC; Scabardi M; Cappellari F; Tasinazzo L; Fortunato L; La Greca G
    Int J Artif Organs; 1993 Aug; 16(8):573-84. PubMed ID: 8225648
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A new approach to determining homopolymer domain sizes in polycarbonate-polyether dialysis membranes by solid-state NMR.
    Lewis RH; Wiesner U; Lehmann S; Spiess HW
    J Biomater Sci Polym Ed; 1994; 6(6):565-71. PubMed ID: 7873508
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Osmotic, diffusive and convective volume and solute flows of ionic solutions through a horizontally mounted polymeric membrane.
    Jasik-Slezak J; Grzegorczyn S; Slezak A
    Polim Med; 2007; 37(3):31-46. PubMed ID: 18251203
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Technical and clinical evaluation of a new synthetic low flux polysulphon membrane for hemodialysis.
    Ronco C; Fabris A; Feriani M; Chiaramonte S; Brendolan A; Emiliani G; La Greca G
    Int J Artif Organs; 1989 Jul; 12(7):450-60. PubMed ID: 2670778
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Preparation and antibacterial property of PES/AgNO3 three-bore hollow fiber ultrafiltration membranes.
    Chen Y; Dang J; Zhang Y; Zhang H; Liu J
    Water Sci Technol; 2013; 67(7):1519-24. PubMed ID: 23552240
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.