145 related articles for article (PubMed ID: 37304247)
1. Utility of a partially covered metal stent for salvage sealing therapy for bleeding caused by duodenal invasion of pancreatobiliary cancers: Case series.
Yamashita Y; Yamazaki H; Kawaji Y; Tamura T; Hatamaru K; Itonaga M; Ashida R; Kitano M
DEN Open; 2024 Apr; 4(1):e253. PubMed ID: 37304247
[TBL] [Abstract][Full Text] [Related]
2. Efficacy of hemostasis by gastroduodenal covered metal stent placement for hemorrhagic duodenal stenosis due to pancreatobiliary cancer invasion: a retrospective study.
Sakamoto Y; Sakamoto T; Ohba A; Sasaki M; Kondo S; Morizane C; Ueno H; Saito Y; Arai Y; Okusaka T
Clin Endosc; 2024 Jun; ():. PubMed ID: 38872407
[TBL] [Abstract][Full Text] [Related]
3. Biliary stenting is not a prerequisite to endoscopic placement of duodenal covered self-expandable metal stents.
Poincloux L; Goutorbe F; Rouquette O; Mulliez A; Goutte M; Bommelaer G; Abergel A
Surg Endosc; 2016 Feb; 30(2):437-445. PubMed ID: 25894447
[TBL] [Abstract][Full Text] [Related]
4. The Dramatic Haemostatic Effect of Covered Self-expandable Metallic Stents for Duodenal and Biliary Bleeding.
Sugimoto M; Takagi T; Suzuki R; Konno N; Asama H; Sato Y; Irie H; Nakamura J; Takasumi M; Hashimoto M; Kato T; Kobashi R; Hikichi T; Ohira H
Intern Med; 2021 Mar; 60(6):883-889. PubMed ID: 33087676
[TBL] [Abstract][Full Text] [Related]
5. Covered self-expandable metallic stent placement for tumor bleeding from duodenal invasion in patients with unresectable pancreatic cancer.
Shibuki T; Fukushi K; Inoue K; Taira T; Satake T; Watanabe K; Sasaki M; Imaoka H; Mitsunaga S; Ikeda M
DEN Open; 2024 Apr; 4(1):e361. PubMed ID: 38601268
[TBL] [Abstract][Full Text] [Related]
6. Early Covered Self-Expandable Metal Stent Placement Is Effective for Massive Post-endoscopic Sphincterotomy Bleeding.
Inoue T; Ibusuki M; Kitano R; Kobayashi Y; Ohashi T; Nakade Y; Sumida Y; Ito K; Yoneda M
Dig Dis Sci; 2020 Nov; 65(11):3324-3331. PubMed ID: 31950313
[TBL] [Abstract][Full Text] [Related]
7. SEMS vs cSEMS in duodenal and small bowel obstruction: high risk of migration in the covered stent group.
Waidmann O; Trojan J; Friedrich-Rust M; Sarrazin C; Bechstein WO; Ulrich F; Zeuzem S; Albert JG
World J Gastroenterol; 2013 Oct; 19(37):6199-206. PubMed ID: 24115817
[TBL] [Abstract][Full Text] [Related]
8. Practical Experiences of Unsuccessful Hemostasis with Covered Self-Expandable Metal Stent Placement for Post-Endoscopic Sphincterotomy Bleeding.
Yoshida M; Inoue T; Naitoh I; Hayashi K; Hori Y; Natsume M; Atsuta N; Kataoka H
Clin Endosc; 2022 Jan; 55(1):150-155. PubMed ID: 33207403
[TBL] [Abstract][Full Text] [Related]
9. Comparison of novel large-bore and conventional-bore covered self-expandable metal stents for malignant gastric outlet obstruction: Multicenter, retrospective study.
Inokuma A; Takahara N; Ishibashi R; Hakuta R; Ishigaki K; Saito K; Saito T; Hamada T; Mizuno S; Yagioka H; Takahashi S; Kogure H; Sasaki T; Hirano K; Ito Y; Isayama H; Nakai Y; Koike K; Fujishiro M
Dig Endosc; 2023 Jan; 35(1):111-121. PubMed ID: 35916499
[TBL] [Abstract][Full Text] [Related]
10. Long-term outcome of self expandable metal stents for biliary obstruction in chronic pancreatitis.
Waldthaler A; Schütte K; Weigt J; Kropf S; Malfertheiner P; Kahl S
JOP; 2013 Jan; 14(1):57-62. PubMed ID: 23306336
[TBL] [Abstract][Full Text] [Related]
11. Novel flower-type covered metal stent to prevent cholecystitis: experimental study in a pig model.
Woo YS; Lee KH; Lee JK; Noh DH; Park JK; Lee KT; Jang KT
Surg Endosc; 2016 Mar; 30(3):1141-5. PubMed ID: 26123330
[TBL] [Abstract][Full Text] [Related]
12. Hemostasis using a covered self-expandable metal stent for pseudoaneurysm bleeding from the perihilar bile duct.
Ishii Y; Nakayama A; Kikuchi K; Nakatani K; Konda K; Mori D; Nishihara S; Oikawa S; Nomoto T; Usami T; Noguchi T; Mitsui Y; Yoshida H
DEN Open; 2023 Apr; 3(1):e150. PubMed ID: 35898842
[TBL] [Abstract][Full Text] [Related]
13. Temporary placement of a covered duodenal stent can avoid riskier anterograde biliary drainage when ERCP for obstructive jaundice fails due to duodenal invasion.
Goutorbe F; Rouquette O; Mulliez A; Scanzi J; Goutte M; Dapoigny M; Abergel A; Poincloux L
Surg Endosc; 2017 Feb; 31(2):625-631. PubMed ID: 27324333
[TBL] [Abstract][Full Text] [Related]
14. Effectiveness of a newly designed antireflux valve metal stent to reduce duodenobiliary reflux in patients with unresectable distal malignant biliary obstruction: a randomized, controlled pilot study (with videos).
Lee YN; Moon JH; Choi HJ; Choi MH; Lee TH; Cha SW; Cho YD; Choi SY; Lee HK; Park SH
Gastrointest Endosc; 2016 Feb; 83(2):404-12. PubMed ID: 26385187
[TBL] [Abstract][Full Text] [Related]
15. Fully Covered Self-Expandable Metal Stents for Treatment of Malignant Biliary Strictures due to Pancreatic Carcinoma.
Samie AA; Stumpf M; Theilmann L
Gastroenterology Res; 2012 Oct; 5(5):195-199. PubMed ID: 27785205
[TBL] [Abstract][Full Text] [Related]
16. Fully covered self-expandable metal stents are effective and safe to treat distal malignant biliary strictures, irrespective of surgical resectability status.
Siddiqui AA; Mehendiratta V; Loren D; Hong SK; Kowalski T
J Clin Gastroenterol; 2011 Oct; 45(9):824-7. PubMed ID: 21921846
[TBL] [Abstract][Full Text] [Related]
17. Temporary placement of a fully covered self-expandable metal stent in the pancreatic duct for management of symptomatic refractory chronic pancreatitis: preliminary data (with videos).
Sauer B; Talreja J; Ellen K; Ku J; Shami VM; Kahaleh M
Gastrointest Endosc; 2008 Dec; 68(6):1173-8. PubMed ID: 19028226
[TBL] [Abstract][Full Text] [Related]
18. Benefits of side-by-side deployment of 6-mm covered self-expandable metal stents for hilar malignant biliary obstructions.
Yoshida T; Hara K; Imaoka H; Hijioka S; Mizuno N; Ishihara M; Tanaka T; Tajika M; Niwa Y; Yamao K
J Hepatobiliary Pancreat Sci; 2016 Sep; 23(9):548-55. PubMed ID: 27345771
[TBL] [Abstract][Full Text] [Related]
19. Fully covered self-expandable metal stents for treatment of malignant and benign biliary strictures.
Abdel Samie A; Dette S; Vöhringer U; Stumpf M; Kopischke K; Theilmann L
World J Gastrointest Endosc; 2012 Sep; 4(9):405-8. PubMed ID: 23125898
[TBL] [Abstract][Full Text] [Related]
20. Endoscopic treatment of nonstricture-related benign biliary diseases using covered self-expandable metal stents.
Irani S; Baron TH; Law R; Akbar A; Ross AS; Gluck M; Gan I; Kozarek RA
Endoscopy; 2015 Apr; 47(4):315-21. PubMed ID: 25521570
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]